Access To Terminal Block & Grounding Strap; Electrical Connection To The Range - Kenmore 79042603311 Installation Instructions Manual

30" dual fuel slide-in range
Table of Contents

Advertisement

Available languages

Available languages

|
Access to Terminal Block &
Grounding
Strap (U.S.A.)
Electrical
Connection
to the
Range (U.S.A.)
This appliance
is manufactured
with the neutral
terminal connected to the frame,
Remove the wire cover here
for access to terminal block
Figure 5
This appliance is manufactured
with
the frame grounded by connection of a grounding
strap between the neutral power supply terminal and
the frame. If used in USA, in a new branch circuit
installation
(1996 NEC), mobile home or recreational
vehicule, where local code do not permit grounding
through neutral (white) wire or in Canada; remove the
grounding strap from the frame and cut the other end,
near the neutral terminal. Connect the appliance in
usual manner.
Three Conductor
Wire Connection
to Range
if local codes
permit connection
of the frame
grounding
conductor
to the neutral
wire of the
copper
power
supply
cord (see Figure 6):
1. Remove the screw which is fixing the rear wire cover,
then remove the rear wire cover (access cover) to
expose range terminal connection
block (see Figure
5).
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply cord
to the center silver-colored
terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected
to the right terminal, black wires
connected to the left terminal) (see figure 6).
3.Put back the rear wire cover using the screw
removed on step 1.
Grounding
Silver Colored Terminal
Strap
Red Wire
Terminal
Block
Electrical
Shock
Hazard
• Electrical
ground
is required
on this appliance.
• Do not connect
to the electrical
supply
until
appliance
is permanently
grounded.
• Disconnect
power to the circuit
breaker
or fuse
box before making
the electrical
connection.
• This
appliance
must
be connected
to
a
grounded,
metallic,
permanent
wiring
system,
or a grounding
connector
should
be connected
to the grounding
terminal
or wire
lead on the
appliance.
Failure to do any of the above could
result in a
fire, personal
injury or electrical
shock.
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at
This Location.
To 240 V Receptacle
Figure 6
1 1/8" (2,9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3,5 cm) Dia. Cord
Kit Hole.

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

790426033107904261331079042613311

Table of Contents