We recommend
to install a pipe elbow right out of the
floor or wall towards the center of the unit to ease the
installation.
Factory
Connected
Power
Supply
Cord (Canada
only)
This range is equipped with a factory-connected
power
cord (see Figure 4). Cord must be connected to a
grounded 120/240 volt or 120/208 volt range outlet. If
no outlet is available, have one installed by a qualified
electrician.
Figure 3
Provide an adequate
Gas Supply
When shipped from the factory, this unit is designed
to operate on 4"(10,16 cm) water column (1,0 kPa)
Natural gas manifold pressure. A convertible
pressure
regulator is connected to the range manifold and
MUST be connected in series with the gas supply line.
If LP/Propane
conversion
kit has been used, follow
instructions
provided with the kit for converting
the
pressure regulator to LP/Propane
use.
Care must be taken during installation of range not to
obstruct the flow of combustion and ventilation
air.
For proper operation, the maximum inlet pressure to
the regulator should be no more than 14" (35,56 cm) of
water column pressure (3,5 kPa). The inlet pressure to
the regulator must be at least 1" (,25 kPa) greater than
the regulator manifold pressure setting. Examples: If
regulator is set for natural gas 4"(10,16 cm) manifold
pressure, inlet pressure must be at least 5" (12,60 cm);
if regulator has been converted for LP/Propane
gas 10"
(25,4 cm) manifold pressure, inlet pressure must be at
least 11" (27,9 cm).
Leak testing of the appliance shall be conducted
according to the instructions
in step 7.
The gas supply line should be ½" or ¾" I.D. (Interior
Diameter)
|
Seal the openings
Seal any openings in the wall behind the range and
in the floor under the range after gas supply line is
installed.
Canada Style
Figure 4
|
Power Supply
Cord Kit (U.S.A.)
The user is responsible for connecting the power
supply cord to the connection
block located behind the
back panel access cover.
This appliance
may be connected by means of
permanent "hard wiring"; flexible armored or
nonmetallic
shielded copper cable (when local code
allow it) or by means of a power supply cord kit.
NOTE: Electric Slide-in Range is shipped from factory
with 1 1/8" (2,9 cm) dia. hole as shown on figure 6. If a
larger hole is required, punch out the knockout.
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, the Installation
Instructions
are not followed, or the strain relief bracket
is discarded.
For mobile homes, new installations
or recreational
vehicles, use only a power supply kit designed for a
range at 125V/250V 30A recommended.
Cord must
have either 3 (when local code permits grounding
through neutral) or 4 conductors.
Terminal on end
of wires must be either closed loop or open spade
lug with upturned ends. Cord must have strain-relief
clamp.
Do not loosen the nuts which secure the
factory-installed
range wiring to terminal block while
connecting
range. Electrical failure or loss of electrical
connection
may occur.
7