Connecting The Gas Supply - Kenmore 796.6142 Series Use & Care Manual

Hide thumbs Also See for 796.6142 Series:
Table of Contents

Advertisement

Available languages

Available languages

GAS DRYERS (continued)
WARNING: To reduce
the.sk of f ire,
electric shock,or injury to persons when using this
appliance, forlowbasicprecautions, incJud{ng
the following:
"Installation and service must be performed by a
qua|ifled
installerr service agency, or the gas supplier.
Failure to do so can result in fire, explosion, or death.
* Use only a new stainless steel Nexible
connector
and
a new AGA-certified
connector.
Failure
to do so can
resultin fire, e xplosion,or death.
"A gas shutoff valve must be installed within
6 ft.
(1.8 m) of the dryer. Failure to do so can result in fire,
explosion: or death.
, The dryer is configured for natural gas when
shipped from the factory. Make sure that the dryer
is equipped with the correct burner nozzle for the
type of gas being used (natural
gas or propane gas).
Failure to do so can result in fire, explosion, or death.
CONNECTING
THE GAS SUPPLY
NOTE: This dryer is configured from the factory set for
natural gas (NG}. mfdryer is to be used with propane
(LP) gas, it must be converted by a qualified
service technician,
OMake
sure that the gas supply to the laundry room is
turned OFF and the dryer {s unplugged. Confirm that
the type of gas available in your laundry room is
appropriate
for the dryer.
Remove the shipping cap from the gas fitting at the
back of the dryer. Be careful not to damage the
threads of the gas connector when removing the
shipping cap.
Connect the dryer to your laundry room's gas supply
using a new flexible stainless steel connector with a s/B
inches NPT fitting.
NOTE: DO NOT use old connectors.
_Securely tighten all connections between the dryer
and your laundry room's gas supply.
_Turn
on your laundry room's gas supply.
_Check
all pipe connections (both internal and external)
for gas leaks with a noncorrosive leak-detection fluid.
Proceed to Venting the Dryer (refer to pages 14-15).
• if necessary, the correct nozzle (for the LP nozzle
kit, order par| number 17025) should be installed
by a quallfled
technician
and the change should be
noted on the dryer. Foffure to do so can result in fire,
explosiont or death.
• AJl connections must be inaccordance
with local
codes and regulations.
Failure to do so can result in
fire, explosion_ o r death.
* Gas dryers MUST exhaust to the outdoors. Failure to do
so can result in fire, explosion, or death.
3/8" NPT Gas
Connection
AGA/CSA-Certified
Stainless Steel
Flexible Connector
._
K.J _
L-----i/8" NPT Pipe
Plug
/
_L\"
Gas Supp, Y
Shutoff Valve
High-Alff|ude
Installatlons
The BTU rating of this dryer is AGA-certified
for
elevations b elow 10,000 feet.
If your gas dryer is being installed at an elevation
above 10,000 feet, it must be derated by a qualified
technician or gas supplier.
11