Introduction
Thank you for purchasing the OMRON M6 Automatic Blood Pressure Monitor.
Display:
The OMRON M6 is a compact, fully automatic blood pressure monitor,
operating on the oscillometric principle. It measures your blood pressure and
M
pulse rate simply and quickly. For comfortable controlled inflation without the
N
need of pressure pre-setting or re-inflation the device uses its advanced
O
"IntelliSense" technology.
Please read this instruction manual thoroughly before using the unit.
P
Please keep for future reference.
Q
For specific information about your own blood pressure, CONSULT YOUR
R
DOCTOR.
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia
or arteriosclerosis.
M. Date/Time display
Please read this section carefully before using the unit.
N. Dual Check System
Warning:
O Systolic blood pressure
• Indicates a potentially hazardous situation which, if not avoided, could result
P. Diastolic blood pressure
in death or serious injury.
Q. Heartbeat symbol
(General Usage)
(Flashes during measurement)
• Always consult your doctor. Self-diagnosis of measurement results and
R. Battery low symbol
self-treatment are dangerous.
S. Average value symbol
• People with severe blood flow problems, or blood disorders, should consult a
doctor before using the unit, as cuff inflation can cause internal bleeding.
(AC Adapter Usage)
2. Preparation
• Never plug in or unplug the power cord from the electric outlet with wet hands.
(Battery Usage)
2.1 Installing/Replacing the Batteries
• If battery fluid should get in your eyes, immediately rinse with plenty of clean
water. Consult a doctor immediately.
1.
Remove the battery cover.
Caution:
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or
2.
Insert four "AA" batteries
moderate injury to the user or patient or damage to the equipment or other property.
as indicated in the battery
(General Usage)
• Do not leave the unit unattended with infants or persons who cannot express their consent.
compartment and then
• Do not use the unit for any purpose other than measuring blood pressure.
replace the battery cover.
• Use only the approved arm cuff for this unit. Use of other arm cuffs may result
in incorrect measurement results.
Notes:
• Make sure that the air tube is not wrapped around other parts of your body
• If the battery low symbol (
when taking measurements at night. This could result in injury when the air
then replace all batteries at the same time.
pressure in the air tube is increased.
• The measurement values continue to be stored in memory even after
• Do not leave the cuff wrapped on the arm if taking measurements during the
the batteries are replaced.
night. This could result in injury.
Disposal of used batteries should be carried out in accordance with the
• Do not use a mobile phone or other devices that emit electromagnetic fields,
national regulations for the disposal of batteries.
near the unit. This may result in incorrect operation of the unit.
• Do not operate the unit in a moving vehicle (car, airplane).
2.2 Connecting the AC Adapter
• To inflate the cuff manually, refer to Section 3.3. If the cuff is over inflated, it
Insert batteries into the battery compartment even when using
can cause internal bleeding.
(AC Adapter Usage)
the AC adapter.
• Use only the original AC adapter designed for this unit. Use of unsupported
adapters may damage and/or may be hazardous to the unit.
Note: When storing the AC adapter with the main unit, be careful not
• Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-tap.
to damage the main unit or cuff.
• Do not use the AC adapter if the unit or the power cord is damaged. Turn off
the power and unplug the power cord immediately.
1.
Insert the AC adapter plug
(Battery Usage)
into the AC adapter jack on
• If battery fluid should get on your skin or clothing, immediately rinse with
the rear side of the main
plenty of clean water.
• Use only four "AA" alkaline or manganese batteries with this unit. Do not use
unit.
other types of batteries.
2.
Plug the AC adapter into an
• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace all four batteries at
electrical outlet.
the same time.
• Remove the batteries if the unit will not be used for three months or more.
To disconnect the AC adapter, unplug the AC adapter from the
electrical outlet first and then remove the AC adapter plug from the
• Do not use new and used batteries together.
General Precautions
main unit.
• Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
• Do not take measurements after bathing, drinking alcohol or caffeine,
2.3 Setting the Date and Time
smoking, exercising or eating.
• Do not forcibly bend the arm cuff or bend the air tube excessively.
1.
Press the
button.
• When removing the air tube, pull on the air plug at the connection with the
2.
main unit not the tube itself.
Set the monitor to the correct date and time before
• Do not inflate the arm cuff when it is not wrapped around your arm.
taking a measurement for the first time.
• Read and follow the "Important information regarding Electro Magnetic
Compatibility (EMC)" in the Technical Data Section.
• Read and follow the "Correct Disposal of This Product" in the Technical Data
Section when disposing of the device and any used accessories or optional parts.
1. Overview
Main unit:
G
A
H
Year
F
B
C
E
3.
Press the O/I START button to store the setting.
Notes:
D
• If the batteries have been removed for 30 seconds or more, the date
A. Display
G. Battery compartment
and time setting will need to be reset.
B. Memory button
H. AC adapter jack
• If the date and time are not set, "-:--" appears during or after
C. O/I START (
) button
measurement.
D. Up/Down (
) buttons
E. Date/Time setting (
) button
F. Air Jack
3. Using the Unit
3.1 Applying the Arm Cuff
I. Arm cuff (Medium cuff: arm
circumference 22 - 32cm)
Remove tight-fitting clothing or tight rolled up sleeve from your
J. Coloured Marker
upper arm.
K. Air tube
Do not place the cuff over thick clothes.
L. Air plug
1.
Insert the air plug into the air jack.
AC adapter:
2.
Put your arm through the cuff loop.
S
T
U
V
W
X
3.
Position the arm correctly.
Y
Z
T. Memory symbol
U. Irregular heartbeat symbol
V. Movement error symbol
The bottom edge of the cuff should be 1 to 2 cm above the elbow.
W. Blood pressure level indicator
Marker (arrow under tube) is centred on the middle of your inner arm.
X. Deflation symbol
Close the fabric fastener FIRMLY.
Y. Cuff wrapping guide
Z. Pulse display and Memory
number
1 to 2 cm
Notes:
• When you take a measurement on the right
arm, air tube will be at the side of your
elbow. Be careful not to rest your arm on
the air tube.
• The blood pressure can differ between the right arm and the left arm,
and therefore also the measured blood pressure values can be
different. Omron recommends to always use the same arm for
measurement. If the values between the two arms differ substantially,
please check with your physician which arm to use for your
) appears on the display, turn the unit off
measurement.
3.2 How to Sit Correctly
To take a measurement, you need to be
relaxed and comfortably seated, under
comfortable room temperature. No
bathing, drinking alcohol or caffeine,
smoking, exercising or eating 30 minutes
before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
• The cuff should be at the same level as your
heart.
3.3 Taking a Reading
Notes:
• To cancel a measurement, press the O/I START button to turn the
unit off and to release the air in the arm cuff.
• Remain still while taking a measurement.
1.
Press the O/I START button.
The cuff will start to inflate automatically.
START
INFLATE
DEFLATE
END
COMPLETE
Dual
Check
Cuff Wrapping Guide
System
1)
Push
or
buttons to
change.
If your systolic pressure is more than
2)
Push the
button to confirm.
220 mmHg
Next setting appears.
After the cuff starts to inflate, press and hold the O/I START
button until the monitor inflates 30 to 40 mmHg higher than
your expected systolic pressure.
Notes:
• The monitor will not inflate above 299mmHg.
Month
Day
Hour
• Do not apply more pressure than necessary.
Minute
Dual Check System
Press the O/I START button, then the Dual Check System lamp lights
and the unit starts detecting a device error. If the unit is accurate and
functioning correctly, the Dual Check System lamp remains lit during
the measurement. If an error is detected, the Dual Check System lamp
flashes and "Er" will appear on the display.
Cuff Wrapping Guide
This monitor checks whether the cuff is applied correctly during the
inflation. When the cuff is applied correctly,
is displayed while
taking a measurement or using the memory function. If the cuff is not
applied correctly,
is displayed. Carefully read and repeat the steps
listed under section 3.1.
4. Troubleshooting and Maintenance
2.
Remove the arm cuff.
4.1 The Icons and Error Messages
3.
Press the O/I START button to turn the monitor off.
Error Display
Cause
The monitor automatically stores the measurement in its
memory.
It will automatically turn off after 2 minutes.
Irregular heartbeats are
Important:
detected.
• Recent research suggests that the following
values can be used as a guide to high blood
pressure for measurements taken at home.
Movement during
measurement.
Systolic Blood Pressure
Above 135 mmHg
Cuff is not applied correctly.
Diastolic Blood Pressure
Above 85 mmHg
This criteria is for home blood pressure measurement.
Blink
The batteries are low.
• Your blood pressure monitor includes an irregular
heartbeat feature. Irregular heartbeats can influence
the results of the measurement. The irregular
The batteries are
heartbeat algorithm automatically determines if the
Lit
exhausted.
measurement is usable or needs to be repeated. If the
measurement results are affected by irregular
heartbeats but the result is valid, the result is shown
Air plug disconnected.
together with the irregular heartbeat symbol (
). If the
irregular heartbeats cause the measurement to be
Arm cuff not applied
invalid, no result is shown. If the irregular heartbeat
correctly.
symbol (
) is shown after you have taken a measurement, repeat
the measurement. If the irregular heartbeat symbol (
) is shown
frequently, please make your doctor aware of it.
Air is leaking from the arm
cuff.
• If you move during measurement, the movement error
symbol (
) will appear on the display. Keep still and
repeat the measurement.
Cuff over inflated.
Note: Wait 2 - 3 minutes before taking another blood pressure
measurement. Waiting between readings allows the arteries to
return to the condition prior to taking the blood pressure
measurement.
Warning:
The arm cuff was inflated
above 299 mmHg
Self-diagnosis of measured results and treatment are dangerous.
when inflating the cuff
Please follow the instructions of your doctor.
manually.
3.4 Using the Memory Function
The monitor automatically stores the result up to 90 sets. It can also
Movement during
calculate an average reading based on the measurements from the last
measurement.
three readings taken within 10 minutes. If there are only two readings in
memory for that period, the average will be based on two readings. If
there is one reading in memory for that period, the average will be
Clothing is interfering with
based on one reading.
Notes:
the arm cuff.
• If the memory is full, the monitor will delete the oldest readings.
• When viewing the reading taken without setting the date and time,
Device error.
"-:--" is displayed instead of the date and time.
Note: The irregular heartbeat symbol (
To View the Average Value
messages.
1.
Press the Memory button.
4.2 Troubleshooting
Problem
Arm cuff not applied
correctly.
Note: If there are no measurements results
stored in the memory, the screen to the
The reading is
Movement or talking
right is displayed.
extremely low (or
during measurement.
high).
Clothing is interfering
To View the Readings Stored in Memory
with the arm cuff.
1.
Press the
button, while the average value is displayed.
The Memory number appears
The air tube is not
securely connected
for a second before the pulse
Alternating
into the main unit.
rate is displayed. The newest
Arm cuff pressure
date/time
set is numbered "1".
does not rise.
display
Air is leaking from the
arm cuff.
Arm cuff deflates too
2.
Press the
or
button to view the readings stored in
The arm cuff is loose.
soon.
memory.
: To the older readings
: To the more recent readings
Cannot measure or
The arm cuff has not
readings are too low
been inflated
or too high.
sufficiently.
To Delete All the Values Stored in Memory
When the memory symbol (
) appears, first press the Memory
The batteries are
button. Then while holding it down, press the O/I START button
empty.
Nothing happens
simultaneously for about 2 - 3 seconds.
when you press the
The batteries have
buttons.
been inserted
incorrectly.
• Press the O/I START button and repeat
measurement.
• If the problem continues, try replacing the
Other problems.
batteries with new ones.
Note: You cannot partially delete the stored readings.
If this still does not solve the problem, contact
your OMRON retail outlet or distributor.
4.3 Maintenance
To protect your unit from damage, please observe the following:
• Do not subject the main unit and the cuff to extreme
Remedy
temperatures, humidity, moisture or direct sunlight.
• Do not fold the cuff or tubing tightly.
Remove the arm cuff. Wait
2 - 3 minutes and then take
• Do not disassemble the unit.
another measurement.
• Do not subject the unit to strong shocks or vibrations
Repeat the steps in section
(for example, dropping the unit on the floor).
3.3. If this error continues to
appear, contact your doctor.
• Do not use volatile liquids to clean the main unit. The
unit should be cleaned with a soft, dry cloth.
Carefully read and repeat
• Use a soft, moistened cloth and soap to clean the arm
the steps in section 3.3.
cuff.
Apply the arm cuff correctly.
• Do not wash the arm cuff or immerse it in water.
Refer to section 3.1.
• Do not use petrol, thinners or similar solvents to clean
the arm cuff.
You should replace them
with new ones ahead of
time.
Refer to section 2.1.
You should replace them
with new ones at once.
Refer to section 2.1.
Insert the plug securely.
Refer to section 3.1.
Apply the arm cuff correctly.
Refer to section 3.1.
Replace the cuff with the
new one.
• Do not carry out repairs of any kind yourself. If a defect
Refer to Chapter 5.
occurs, consult your OMRON retail outlet or distributor
Repeat measurement.
as mentioned on the packaging.
Remain still and do not talk
Calibration and Service
during measurement.
Refer to section 3.3.
• The accuracy of this blood pressure monitor has been
carefully tested and is designed for a long service life.
If "E2" appears repeatedly,
• It is generally recommended to have the unit inspected
inflate the cuff manually
every two years to ensure correct functioning and
until it is 30 to 40 mmHg
accuracy. Please consult your authorised OMRON
above your previous
measurement result.
dealer or the OMRON Customer Service at the address
Refer to section 3.3.
given on the packaging or attached literature.
Do not inflate the cuff above
4.4 Storage
299 mmHg.
Refer to section 3.3.
Keep the unit in its storage case when not in use.
Repeat measurement.
1.
Unplug the air tube from the air jack.
Remain still and do not talk
during measurement.
2.
Gently fold the air tube into the arm cuff.
Refer to section 3.3.
Note:
Remove any clothing
Do not bend the air tube excessively.
interfering with the arm cuff.
Refer to section 3.1.
Contact your Omron retail
outlet or distributor.
3.
Place the arm cuff and main unit in the
storage case.
) may also be displayed with error
Do not store the unit in the following situations:
• If the unit is wet.
• Locations exposed to extreme temperatures,
Cause
Remedy
humidity, direct sunlight, dust or corrosive
vapours.
Apply the arm cuff
• Locations exposed to vibrations, shocks or where it will be at an
correctly.
angle.
Refer to section 3.1.
Remain still and do not
talk during
5. Optional Parts
measurement.
Refer to section 3.3.
Medium Arm Cuff
Large Arm Cuff
Small Arm Cuff
Remove any clothing
Arm circumference
Arm circumference
Arm circumference
interfering with the arm
22 - 32 cm
32 - 42 cm
17 - 22 cm
cuff.
Refer to section 3.1.
Make sure that the air
tube is connected
CM2-9513256-6
CL2-9513255-8
CS-4997067-0
securely.
(Model: HEM-CR24)
(Model: HEM-CL24)
Refer to section 3.1.
CM1-9997578-9
CL1-9996760-3
Replace the arm cuff
with a new one.
AC Adapter "R"
Refer to Chapter 5.
Apply the cuff correctly
so that it is firmly
wrapped around the arm.
Refer to section 3.1.
Inflate the cuff so that it
is 30 to 40 mmHg above
R Adapter-9997605-0
your previous
measurement result.
Refer to section 3.3.
Replace the batteries
with new ones.
Refer to section 2.1.
Insert the batteries with
the correct (+/-) polarity.
Refer to section 2.1.
HEM-7211-ARU_A_M03_091113.pdf
6. Technical Data
Product Description
Automatic Blood Pressure Monitor
Model
OMRON M6 (HEM-7211-ARU)
Display
LCD Digital Display
Measurement Method
Oscillometric method
Measurement Range
Pressure: 0 to 299 mmHg
Pulse: 40 to 180/min.
Accuracy
Pressure: ±3 mmHg
Pulse: ±5% of display reading
Inflation
Fuzzy-logic controlled by electric pump
Deflation
Automatic pressure release valve
Pressure Detection
Capacitive pressure sensor
Memory
90 Measurements with date and time
Rating
DC6V
4W
Power Source
4 "AA" batteries 1.5V or AC adapter
(R Adapter-9997605-0, INPUT AC100-240V 50/60Hz
0.1A)
Battery Life
Capacity of new alkaline batteries is approx.
1000 measurements
Applied Part
= Type B
Protection Against
Internally powered ME equipment
Electric Shock
(When using only the batteries)
= Class II ME equipment
(When using the AC adapter)
Operating
+10°C to +40°C / Maximum: 30 to 85% RH
temperature/ Humidity
Storage temperature/
-20°C to +60°C / Maximum: 10 to 95% RH / 700-1060hPa
Humidity
Console Weight
Approximately 380g without batteries
Cuff Weight
Approximately 120g
Outer Dimensions
Approximately 123 (w) mm × 85 (h) mm × 158 (l) mm
Cuff Dimensions
Approximately 146 mm × 446 mm (Medium cuff: arm
circumference 22 to 32 cm)
Cuff Material
Nylon and polyester
Package Content
Main unit, cuff, instruction manual, storage case,
battery set, AC adapter, guarantee card, blood
pressure pass
Note: Subject to technical modification without prior notice.
• This device fulfils the provisions of EC directive 93/42/EEC (Medical Device
Directive).
• This blood pressure monitor is designed according to the European Standard
EN1060, Non-invasive sphygmomanometers Part 1: General Requirements
and Part 3: Supplementary requirements for electromechanical blood
pressure measuring systems.
• This OMRON product is produced under the strict quality system of OMRON
Healthcare Co. Ltd., Japan. The Core component for OMRON blood pressure
monitors, which is the Pressure Sensor, is produced in Japan.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC's and mobile
(cellular) telephones, medical devices in use may be susceptible to
electromagnetic interference from other devices. Electromagnetic interference
may result in incorrect operation of the medical device and create a potentially
unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility)
with the aim to prevent unsafe product situations, the EN60601-1-2:2007
standard has been implemented. This standard defines the levels of immunity to
electromagnetic interferences as well as maximum levels of electromagnetic
emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this
EN60601-1-2:2007 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which generate
strong electrical or electromagnetic fields, near the medical device. This may
result in incorrect operation of the unit and create a potentially unsafe situation.
Recommendation is to keep a minimum distance of 7 m. Verify correct operation
of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at
OMRON Healthcare Europe at the address mentioned in this instruction manual.
Documentation is also available at www.omron-healthcare.com.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it
should not be disposed of, with other household wastes at the end
of its working life. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, please separate
this from other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they can
take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions
of the purchase contract. This product should not be mixed with other commercial
wastes for disposal.
This product does not contain any hazardous substances.
Manufacturer
OMRON HEALTHCARE CO., LTD.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto,
615-0084, Japan
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp,The Netherlands
www.omron-healthcare.com
Exclusive
ComplectService Ltd.
distributor in
1/1, Tishinskaya sq, Moscow, Russia,123056
www.csmedica.ru
Russia & importer
Production Facility
OMRON DALIAN CO., LTD.
Economic & Technical Development Zone
Dalian 116600, China
Made in China

Advertisement

loading

Summary of Contents for Omron M6

  • Page 1 Be careful not to rest your arm on Please follow the instructions of your doctor. • This OMRON product is produced under the strict quality system of OMRON Refer to section 3.3. Keep the unit in its storage case when not in use.
  • Page 2 измерений артериального давления. • Данный прибор удовлетворяет требованиям директивы ЕС 93/42/EEC Обратитесь к разделу 2.1. OMRON M6 — это компактный, полностью автоматический прибор для измерения (директива по медицинским приборам). артериального давления, работающий на основе осциллометрического метода. Он • Тонометр снабжен функцией определения нерегуляр- Их...