This system has been tested and certified in filter model GEMSWFaccording to NSF/ANSI S tandards 42 and 53 for reduction of the substunces listed below.
The concentration of the indicated substances in water entering the system was reduced to o concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI S tandards 42 and 55.* (Safety factors built in for unmetered usage.}
Standard No. 42: Aesthetic effects
Parameter
'
USEPAMCL
Effluent'
% Reduction
I
Concentration
Average
'
Maximum
..... Average
'
Maximum
Min. Required Reduction
2.0 mg/L ± 10%
0.06 mg/L
0.10 mg/L
97%
9.1%
->50%
at least 10,000 particles/
408,333
670,000
95.5%
89.4%
> 85%
mL
Standard
No. 53: Hearth
effects
..........
Effluent
% Redaction
..........
Parameter
USEPAMCL
Concentration
Average
Maximum
1 NTU....
11_+1 NTU....
0.38 NTU
0.S NTU
99.95% Reduction
Minimum 50,000 L
< 1 #/L
4 #/L
0.010 mg/L
0.15 mg/L ± 10%
< 1 ppb
< 1 ppb
0.010 mg/L
0.1S mg/L ± 10%
3.1 ppb
9.0 ppb
0.002 mg/L
0.006 mg/L ± 10%
0.34 ppb
0.7 ppb
0.002 mg/L
0.006 mg/L ± 10%
0.66 ppb
1.5 ppb
0.0002 mg/L
0.002 mg/L _+ 10%
< 0.02 ppb
< 0.02 ppb
0.003 mg/L
0.009 mg/L ± 10%
<O.Sppb
< O.OS ppb
0.070 mg/L
0210 my/L± 10%
7.7 ppb
35 ppb
0.003 mg/L
0.015 mg/L ± 10%
< 1 ppb
< 1 ppb
0.005 mg/L
0.015 mg/L ± 10%
< 0.S ppb
< 0.5 ppb
0.040 mg/L
0.080 mg/L ± 10%
< 1 ppb
i ppb
0.075 mg/L
0.225 mg/L _+10%
< 0.5 ppb
< 0.5 ppb
99% Reduction
107 to 10 8fibers/L;
< 0.17 MF/L
<0.17 MF/L
fibers > 10pro in length
*Testedusing pressure of 60 psig;pH of 7.5± 0.5;temp of 680± 5%120 ° ±2.5°C}.
**Measurement in Partides/mL Particles used were 0.5-1microns.
***Based onthe useof Cryptosporidium parvum oocysts.
.... NTU=NephelometricTurbidity Units
Capacity 300 gallons (i,135 liters). Contaminant reduction determined by NSFtesting.
Average
96.5%
> 99.99%
99.3%
98.0%
94.0%
88.4%
> 99.0%
> 93.9%
96.0%
>92.9%
>96.8%
> 98.7%
>99.7%
> 99%
Maximum
95.4%
> 99.99%
99.3%
95,5%
89.6%
73.7%
> 99.0%
> 94.3%
82.0%
> 92.9%
> 97.0%
>98.7%
> 99.8%
>99%
Product Water
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 rng/L
0.040 mg/L
0.075 mg/L
99% Reduction
Application
Guidelines/Water
Supply Parameters
ServiceFlow
Water Pressure
WaterSupply
Water Temperature
It is essentialthat the manufacturer'srecommended installation,maintenanceand filter replacementrequirementsbe carriedout for the productto perform asadvertised.
See insert for Warranty information.
Operating
Specifications
®Pressure requirement:
40-120
psi (2.8-8.2 bar), non-shock
• Temperature:
33-100°F (0.6-38°C)
• Flow rote: 0.9 gpm (3.14 Ipm)
General
Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 4-1/2 gallons (about five minutes} to purge
trapped air.
• Replace cartridge
when flow becomes too slow.
• Protect from freezing
by removing
filter cartridge
when temperatures
are
expected
to drop below 40°F (4.4°C). Do not install systems
in areas where
ambient
ternperatures
may go above 100% or below 40°E Do not install
on a hot water
supply.
Special N otices
• Installation
instructions
ore included with the product when shipped.
, This drinking water system must be maintained
according to manufacturer's
instructions,
including
replacement
of filter curtridges.
• Do not use with water that is microbio)ogically
unsafe or of unknown quality with-
out adequate
disinfection
before or after the system. Systems certified for cyst
reduction
may be used on disinfected
wuter that may contain filterable
cysts.
• The contaminants
or other substances
removed
or reduced by this water
treatment
system are not necessarily in your water.
, Check for compliunce
with the applicable
state and local tows and regututions.
. Note that while the testing wus performed
under standard laboratory
conditions,
actual performance
may vary. Systems must be instulled and operated
in
accordance
with manufacturer's
recommended
procedures
and guidelines.
• Installation
and use MUST comply with all state and local plumbing codes. Do not
instull if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa), you should install a pressuredimiting
valve. Contact a plumbing
professionul
if you ore uncertuin
how to check your water pressure.
- Do not install where water hammer conditions
may occur. If water hummer
conditions
exist you must install a water
hammer arresten Contact a plumbing
professional
if you are uncertain
how to check for this condition.
. Where o backflow
prevention
device is installed on a water system, u device for
controlling
pressure due to thermal expansion
must be installed.
For conditions of use, heulth claims certified by the California Department
of Public
Health, and rep)ocements,
see performance
data sheet. California Deportment
of Public Heulth Certification
#06-1834. The contaminants
or other substances
removed or reduced by this water filter are not necessarily
in oil users' woten
Tested and Certified by NSF International against ANSI/NSF Standards 42 and 53 in model GE MSWF for the reduction of:
Standard
No. 42: Aesthetic
Effects
• Chemical
- Chlorine
Taste and Odor
• Mechanical Filtration
- Particulate Reduction, Class I
GE
Appliances
Appliance Pork
Louisville, KY 40225
geapplianceparts.com
Standard No. 53: Health Effects
,, Chemical Reduction
- Atrazine Reduction
- Endrin Reduction
- Benzene and Corbofuron Reduction
- 1,4 Dichlorobenzene and
2,4-D Reduction
- Lead and Lindane Reduction
- Mercury and Toxophene Reduction
• Mechanical Filtration
- Cyst and Asbestos Reduction(_
REPLACEMENT
ELEMENT
EPA#10350-MN-005
© 2010 General Electric Company
PC61577C
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pss28kshbcssPse25kshbhss

Table of Contents