Clay Paky ALPHA PROFILE 700 Instruction Manual
Hide thumbs Also See for ALPHA PROFILE 700:
Table of Contents
  • Safety Information
  • Informazioni DI Sicurezza
  • Consignes de Sécurité
  • Informationen zur Sicherheit
  • Informaciones de Seguridad
  • Unpacking and Preparation
  • Installation and Start-Up
  • Control Panel
  • Using the Menu
  • Menu Setting
  • Setup Menu
  • Options Menu
  • Autofocus Mode
  • Information Menu
  • Manual Control
  • Advanced Menu
  • Test Menu
  • Maintenance
  • Optional Accessories
  • Technical Information
  • Cause and Solution of Problems
  • Channel Function

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 38
INDEX
Page Contents
2
Safety Information
4
Informazioni di sicurezza
6
Consignes de sécurité
8
Informationen zur Sicherheit
10
Informaciones de suguridad
12
Unpacking and preparation
13
Installation and start-up
14
Control panel
16
Menu setting
24
Maintenance
32
Technical information
32
Cause and solution of problems
33
Channel functions
ALPHA PROFILE 700
ALPHA PROFILE 700
INSTRUCTION MANUAL
EN
IT
FR
DE
ES
Congratulations on choosing a Clay Paky product!
We thank you for your custom.
Please note that this product, as all the others in the rich Clay
Paky range, has been designed and made with total quality to
ensure excellent performance and best meet your expectations
and requirements.
Carefully read this instruction manual in its entirety and keep it
safe for future reference. It is essential to know the information
and comply with the instructions given in this manual to ensure
the fitting is installed, used and serviced correctly and safely.
CLAY PAKY S.p.A. disclaims all liability for damage to the fitting
or to other property or persons deriving from installation, use and
maintenance that have not been carried out in conformity with this
instruction manual, which must always accompany the fitting.
CLAY PAKY S.p.A. reserves the right to modify the
characteristics stated in this instruction manual at any time and
without prior notice.
1
1
C61365
ST
"
"
C61366

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALPHA PROFILE 700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Clay Paky ALPHA PROFILE 700

  • Page 1 Installation and start-up the fitting is installed, used and serviced correctly and safely. CLAY PAKY S.p.A. disclaims all liability for damage to the fitting Control panel or to other property or persons deriving from installation, use and...
  • Page 2: Safety Information

    According to The fixture must be positioned so that the minimum distance between the front lens and human eye is at least 1 EN 62471 metre to prevent personal photobiological risks. ALPHA PROFILE 700 & “ ”...
  • Page 3 • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP) ALPHA PROFILE 700 & “ ”...
  • Page 4: Informazioni Di Sicurezza

    Secondo la norma Il proiettore deve essere posizionato in modo tale che la minima distanza della lente del proiettore dall’occhio umano EN 62471 sia di almeno 1 metro per prevenire rischi fotobiologici alla persona. ALPHA PROFILE 700 & “ ”...
  • Page 5 • 2006/95/CE - Sicurezza delle apparecchiature alimentate in Bassa Tensione (LVD) • 2004/108/CE - Compatibilità Elettromagnetica (EMC) • 2011/65/UE - Restrizione d’uso di determinate sostanze pericolose (RoHS) • 2009/125/CE - Specifiche per la progettazione ecocompatibile dei prodotti connessi all’energia (ErP) ALPHA PROFILE 700 & “ ”...
  • Page 6: Consignes De Sécurité

    à l’œil humain de la lentille du projecteur soit de 1 mètre minimum Selon la norme pour prévenir des dangers photo-biologiques à la personne. EN 62471 ALPHA PROFILE 700 & “ ”...
  • Page 7 • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP) ALPHA PROFILE 700 & “ ”...
  • Page 8: Informationen Zur Sicherheit

    Nicht die Lampe fixieren, wenn sie in Betrieb ist. Kann für die Augen gefährlich sein. Der Projektor muss so Gefahrenklasse 2 positioniert werden, dass der Mindestabstand der Projektorlinse vom menschlichen Auge mindestens 1 Meter Gemäß Norm EN 62471 beträgt, um einer fotobiologischen Gefährdung der Person vorzubeugen. ALPHA PROFILE 700 & “ ”...
  • Page 9 • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP) ALPHA PROFILE 700 & “ ”...
  • Page 10: Informaciones De Seguridad

    1 metro para prevenir peligrosidad 2 riesgos fotobiológicos a la persona. Según la norma El producto es concebido para ser utilizado en los siguientes ambientes: EN 62471 ALPHA PROFILE 700 & “ ”...
  • Page 11 • 2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD) • 2004/108/EC - Electromagnetic Compatibility (EMC) • 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS) • 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP) ALPHA PROFILE 700 & “ ”...
  • Page 12: Unpacking And Preparation

    Lamp 700W (fitted into projector) Packing contents - Fig. 1 UNLOCKED LOCKED LOCKED UNLOCKED PAN Mechanism Lock and Release (every 90°) - Fig. 2 TILT Mechanism Lock and Release (every 45°) - Fig. 3 ALPHA PROFILE 700 & “ ”...
  • Page 13: Installation And Start-Up

    WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base. Connecting and disconnecting power cable - Fig. 5 ALPHA PROFILE 700 & “ ”...
  • Page 14: Control Panel

    During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status. It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the key will be cancelled. ALPHA PROFILE 700 & “ ”...
  • Page 15: Using The Menu

    All that is needed is to press to momentarily activate the display and thus access the settings. Once the required operations have been carried out, the display will switch off again after a wait time of 30 seconds. ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 16: Menu Setting

    Low fan speed Test Pan / Tilt Advanced 1234 4-700W Display Auto fan speed Colour Upload Default Firmware Setting Preset Beam User Preset 1 Setup Model Gobo User Preset 2 Calibration User Preset 3 ALPHA PROFILE 700 & “ ”...
  • Page 17: Setup Menu

    Custom IP address address Allows you to set the IP address manually by the user default. Custom IP Custom IP mask mask Allows you to set manually the Subnet Mask by the user default. ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 18: Options Menu

    Lets you assign the Tilt channel “home” position at the end of Reset, with- Def Pos out a DMX input signal. 1) Press , the current setting appears on the display. 2) Use the UP and DOWN keys to select one of the following settings: 12.5% ALPHA PROFILE 700 & “ ”...
  • Page 19: Autofocus Mode

    Limited Zoom Range: The “Autofocus” works only in the optical run that was specifically designed for the projector in question. Complete Zoom Range: The “Autofocus” also works in overrun 3) Press to confirm the selection or LEFT to keep the current set- ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 20 Mechanic Power Mode 4-700W Full fan speed 400W Low fan speed 4-700W Auto fan speed Display Default Reset To Setting Preset Dafault Go Back User Load Preset 1 Preset 1 Save To Preset 1 ALPHA PROFILE 700 & “ ”...
  • Page 21: Information Menu

    (Are you sure ?) appears on the display. 3) Select YES to reset partial counter or NO to keep the current setting and return to the top menu level ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 22: Manual Control

    2) Use the UP and DOWN keys to turn the lamp on (On) or off (Off) 3) Press to confirm the selection or LEFT to keep current settings and return to the top level. ALPHA PROFILE 700 & “ ”...
  • Page 23: Advanced Menu

    – a confirmation message appears on the display (Reset calibration to factory default ?). 2) Select YES to reset calibration to factory default or NO to keep the current setting and return to the top menu level. ALPHA PROFILE 700 & “ ”...
  • Page 24: Maintenance

    1/4 Turn Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section. Opening the head covers - Fig. 10 Closing the head covers - Fig. 11 ALPHA PROFILE 700 & “ ”...
  • Page 25 CAUTION: fast lamp ON-OFF cycles (for example 10 minutes ON / 10 minutes OFF) will reduce the lamp life. Upper Side Lower Side Lamp regulation - Fig. 14 To centre the lamp, turn the three adjusting screws as shown in the figure. ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 26 085531/001 Replacing rotating gobos (ø 25.7 mm - max 19 mm image – thickness 1.1 mm) - Fig. 16 IMPORTANT: Please contact CLAY PAKY before using customized gobos. IMPORTANT: Use only glass gobos on the rotating gobos wheel. ALPHA PROFILE 700 &...
  • Page 27 • General cleaning of internal parts. • Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky. • General visual check of the internal components, cabling, mechanical parts, etc.
  • Page 28 Upper Side Lower Side Extraction of the effect modules: Preliminary operations - Fig. 19 Upper Side Upper Side ALPHA PROFILE 700 & “ ”...
  • Page 29 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 20, 21 and 22 in reverse order. ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 30 Battery removal - Fig. 23 This product contains a rechargeable lead-acid or lithium iron tetraphosphate battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force. LiFePO4 ALPHA PROFILE 700 & “ ”...
  • Page 31: Optional Accessories

    OPTIONAL ACCESSORIES C61188 - HEAVY FROST FILTER KIT ALPHA PROFILE 700 & “ ”...
  • Page 32: Technical Information

    Signal transmission cable faulty or disconnected. Replace the cables. Incorrect addressing. Check addresses (see instructions). Fault in the electronic circuits. Call an authorised technician. Lenses or reflector broken Call an authorised technician. Dust or grease deposited. Clean (see instructions). ALPHA PROFILE 700 & “ ”...
  • Page 33: Channel Function

    NB: To prevent accidental breakage of the effects, which could collide with each other during transport, ALPHA PROFILE 700 & “ST” before switching the projector OFF check that all the projector Channels have been excluded (DMX level = 0 bit).
  • Page 34 LAVENDER + AQUAMARINE LAVENDER Random Macro Color LIGHT GREEN + LAVENDER LIGHT GREEN (only for Macro effects) GREEN + LIGHT GREEN GREEN Unused Range CTO + GREEN RED + CTO WHITE + RED WHITE ALPHA PROFILE 700 & “ ”...
  • Page 35 252 - 255 MAXIMUM APERTURE FAST PULSATION, FAST CLOSING SLOW PULSATION, FAST CLOSING FAST PULSATION, FAST OPENING SLOW PULSATION, FAST OPENING FAST PULSATION SLOW PULSATION 128 - 131 MAXIMUM APERTURE MINIMUM APERTURE ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 36 EFFECT EFFECT BLADE IN BLADE IN BLADE OUT BLADE OUT • BLADE UP 2 - channel: 17 • BLADE RG 2 - channel: 21 EFFECT EFFECT BLADE IN BLADE IN BLADE OUT BLADE OUT ALPHA PROFILE 700 & “ ”...
  • Page 37 AUTOFOCUS priority: EFFECT 1 - Blades 100 METRES 2 - Rotating Gobo 3 - Iris 10 METRES 9 METRES 8 METRES 7 METRES 6 METRES 5 METRES 4 METRES 3 METRES AUTOFOCUS OFF ➔ Continue ALPHA PROFILE 700 & “ ”...
  • Page 38 Off) 40-51 MACRO 3 28-39 MACRO 2 16-27 MACRO 1 12-15 STAND BY BLACK 8-11 STAND BY MACRO OFF Operation with option InvertPan (Tilt conventionally represented at 35 bit and option Invert Tilt Off) ALPHA PROFILE 700 & “ ”...
  • Page 39 (Pan conventionally represented at 0 bit and option Invert Pan Off) • LAMP CONTROL (only with option LAMP DMX On) - channel: 37 IMPORTANT: Alpha Profile 700 is not provided with hot restrike igniter EFFECT LAMP ON (FULL POWER) Lamp ignition after 5 s in full power levels.
  • Page 40: Timing Channels

    Rotating Gobo change - Framing - Framing rotation TIME TABLE Seconds Seconds Seconds Seconds Seconds Seconds Full 10.2 10.4 10.6 Follow cue Data CLAY PAKY - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311 - Fax +39-035-301876 - www.claypaky.it S.p.A.

This manual is also suitable for:

Alpha profile 700 "st"

Table of Contents