Starting/Stopping - Jacobsen Eclipse 118 63313 Technical Manual

Table of Contents

Advertisement

Available languages

Available languages

5
OPERATION
5.4

STARTING/STOPPING _____________________________________________________

1. Prepare power module to energize unit.
Battery Power Module: Disconnect battery charger
and connect power connector.
Gen-Set Power Module:
a. Check oil level and fuel supply then open fuel
valve lever (P).
b. Move the choke lever (N) to the "CLOSED"
position.
c.
Set engine switch (M) to "ON" and power switch
(D) to run position.
d. Start the engine.
e. Once engine starts move choke lever (N) to the
"OPEN" position.
2. Make certain O.P.C. bail (C) is disengaged, reel
switch (E) is off and parking brake (A) is engaged.
3. Turn power switch (D) to start position and release.
LCD display (G) should show startup display for 5
seconds, then switch to system voltage.
If system fails to initialize, check to see if power
connector is properly attached or if circuit breaker (F)
is tripped. Reset circuit breaker if necessary.
4. Check system voltage on LCD display (G). If the
system voltage screen is not on the display, press
either of the orange buttons (H) to forward display to
the correct screen. If system voltage is low,
recharge batteries or check generator output before
operating.
5. To mow or transport unit, push O.P.C. bail (C) to the
left and engage.
6. To stop the unit, release the O.P.C. bail, engage
parking brake and set power switch to "OFF"
position.
7. Battery
Power
connector and connect battery pack to charger.
Gen-Set Power Module: Turn engine switch (M) to
off position and close fuel valve (P).
22
Module:
Disconnect
A
power
B
E
M
N
OFF
P
G
C
D
H
F
Figure 5A
Figure 5B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents