8. On the Setup page, press the line select key labeled CALB to enter calibration mode. This will take a
few seconds.
9. The GMX 200 will flash all faults briefly and the text near the bottom of the display will read
"Calibration Enabled" to indicate calibration mode has been entered. If this fails, turn power off and
try again.
At this point, follow directions in the ART2000 Installation Manual starting with "400 Hz Ref Gain"
section. Selection of calibration parameters is done by adjusting the gain setting according to the values in
the ART2000 Installation Manual. On the GMX 200, the "smart keys" labeled "Gain" are used to adjust
the gain setting and select the parameter to be calibrated. Follow the ART2000 Installation Manual
instructions for calibrating the selected parameters.
5.4.1.2
G WX 68 Calibration Procedure Using the GMX 200
9 7 B
The following procedure covers both analog and ARINC 429 stabilization inputs. If one or the other
input is not available, that particular option need not be calibrated.
Calibration parameters are stored in the GWX 68 configuration module (not the GMX 200 configuration
module). When replacing a GWX 68, an error message will be displayed indicating the configuration data
in the GWX 68 does not match the data in the configuration module. Perform the Save Configuration
procedure in Section
5 .4.1.2.7
X
GWX 68. When the data from the Configuration Module is saved in the GWX 68, recalibration of the
radar is not necessary.
If an analog stabilization input is used, the radar stabilization source must be removed from the aircraft
and mounted on a tilt table for proper calibration.
Analog stabilization values for pitch and roll can only be adjusted if the GWX 68 is provided with a 400
Hz reference input.
The GMX 200 must be in the Install mode to calibrate the radar head. Follow the instructions below:
1. Turn the GMX 200 on.
2. After boot-up is complete, key-in the install sequence 1, 4, 6, on the line select keys to enter the
Install mode.
3. Press the FN key until one of the smart key options is RADAR. If the RADAR option is not
available, ensure that the GMX 200 is configured for a radar source.
4. Press the smart key corresponding to the RADAR option. You will now switch to the Radar page.
5. Press the STBY line select key on the GMX 200 to put the radar unit into standby mode. This may
take up to twenty seconds.
6. Once the radar is in standby mode, one of the menu options will be TEST. Press the TEST key.
7. Once the GMX 200 is in Test mode, press the MENU/ENT key to switch to the Setup page.
8. On the Setup page, press the key labeled CALB to enter calibration mode. This will take a few
seconds.
9. The GMX 200 will flash all faults briefly and the text near the bottom of the display will read
"Calibration Enabled" to indicate calibration mode has been entered. If this fails, turn power off and
try again.
If the only stabilization source is ARINC 429, proceed directly to Section
needed for ARINC 429 input from an AHRS since it is assumed the AHRS was previously calibrated for
level attitude.
Page 5-14
Revision F
to load the configuration data from the Configuration Module into the
X
5 .4.1.2.7
. No adjustment is
X
X
GMX 200 Installation Manual
190-00607-04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents