Majestic fireplaces 360DVS2 Homeowner's Installation And Operating Manual page 34

Multisided top/rear vent convertible direct vent
Table of Contents

Advertisement

360 DVS Series Direct Vent Fireplaces
E
F
Fig. 49 Replace regulator.
FC108
Honeywell Gas Control Valve (Fig. 50)
SIT
The Honeywell valve fitted to this unit is suitable for use
regulator
with LP or Natural Gas. It is converted to the required
gas application by installing a color-coded conversion
conversion
screw.
10/03
a) Using a suitable small screwdriver, lift out the cen-
tral regulator cap from the "HI/LO" knob on the valve.
b) Unscrew the exposed conversion screw.
c) Insert the new color coded conversion screw. Do
not overtighten the screw; it must be finger- tight.
d) Refit the regulator cap.
e) Mount conversion label supplied with the conver-
sion screw to the valve in a visible position.
34
D
Fig. 50 Honeywell conversion screw replacement.
FC108
10. Reassemble fireplace in the reverse order, except
11. After bleeding the gas line and checking for leaks
12. Fire up the unit. Check for flame impingement on
13. Check manifold and supply pressures against the
Regulator Cap
for the window frame assembly. Leave this off until
HV120
after unit has been checked for leaks and the gas
supply has been bled.
Honeywell valve
conversion
9/24/02 djt
with a soap solution, replace the window frame as-
sembly.
the logs, adjusting them as necessary.
appliance specifications.
The procedure for converting from one gas
to another is the same regardless of the
initial gas used. The only variations are
in orifice sizes and component part num-
bers. Your authorized service provider will
ensure correct parts are used.
Conversion
Screw
Pressure Regu-
lator Housing
HV120
10006326

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

360dvsl360dvs3360dvsr360dvs3360dvsl360dvsr

Table of Contents