Electronic Gas Control Valve; General Venting - Majestic fireplaces 360DVS2 Homeowner's Installation And Operating Manual

Multisided top/rear vent convertible direct vent
Table of Contents

Advertisement

Electronic Gas Control Valve

This appliance may be fitted with a Honeywell ignition
module.
Installation of the remote ON/OFF starter switch on
electronic ignition units (Fig. 12):
1. Thread the wiring through the holes on the side
panels of the appliance. Take care not to cut the wire
or insulation on metal edges. Route the wire to a
conveniently located receptacle box.
2. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
3. Connect the white wire from the wall switch to the
black wire from the transformer, using an approved
wire nut. Connect the black wire from the wall switch
to the black wire running from the #6 position of the
ignition module, also using an approved wire nut.
Your fireplace is approved to be vented either through
the side wall, or vertically through the roof.
Only CFM Corporation venting components, specifi-
cally approved and labeled for this fireplace, may be
used.
Venting terminals shall not be recessed into a wall or
siding.
Horizontal venting must be installed on a level plane
without an inclining or declining slope.
There must not be any obstruction such as bushes,
10006326
Fig. 12 Honeywell ignition module.

General Venting

garden shed, fencing, deck or utility building within 24"
(610mm) from the front of the termination hood.
Do not locate the termination hood where excessive
snow or ice buildup may occur. Be sure to check the
vent termination area after snow falls; clear it to prevent
accidental blockage of the venting system. When using
a snow blower, make sure snow is not directed toward
the vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ-
ing minimum clearances as shown on the following
page.
360DVS Series Direct Vent Fireplaces
PILOT
HONEYWELL IGNITION MODULE
24V
MV
MV/VP PV
GRD
1
2
3
5
GREEN
RED
ORANGE
ORANGE
HI
NOVA SIT 822 VALVE
WHITE
POWER CORD
W/FEMALE SPADE
120 VAC RTN
24 VAC HOT
WHITE
BLACK
YELLOW
BLACK
GREEN
24 VAC RET
120 VAC HOT
40VA TRANSFORMER
24V
SENSE SPARK
6
8
9
BLACK
BLUE
BLACK
OFF
WHITE
WALL SWITCH
BLACK
WHITE
FP1225
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

360dvsl360dvs3360dvsr360dvs3360dvsl360dvsr

Table of Contents