U-Line 1224BEV User Manual page 64

1000 series beverage center
Hide thumbs Also See for 1224BEV:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
ERRORS
*All errors are logged in memory.
*Only door error is displayed on the display and has an
audible signal.
*For 68118 models, pump error is displayed via alert light
with no audible alert.
E1: Thermistor 1 open.
E2: Thermistor 2 open.
E3: Thermistor 3 open.
E4: Thermistor 4 open.
E5: Thermistor 1 shorted.
E6: Thermistor 2 shorted.
E7: Thermistor 3 shorted.
E8: Thermistor 4 shorted.
E9: Door open error.
PI: Pump Circuit open
1000
Model
2000
#
(120V)
1215R
07
2218R
1215WC
12
2218RG
1224BEV
13
2218WC
1224DWR
08
2224BEV
1224R
14
2224FZR
09
2224R
1224RF
1224RSOD
10
2260R
1224WC
15
2224RG
CLR 1215
18
ADA24R
CO 1224F
19
Model
2000
Model
#
(230V)
#
05
2245R
55
04
2245RDC
54
06
224WC
57
00
2260DC
50
11
2260FZR
57
02
2260R
52
01
2260RDC
51
03
2260WC
53
17
Programming the unit to correct model number
1. Unplug unit and install new board
2. Push and hold the hidden icon
3. Plug the unit in
4. Release the hidden icon
5. Use the UP/DOWN arrows to scroll to correct model
number from chart
6. Push and release the light icon
7. Unit flashes OFF/ON then locks in model
u-line.com