SERVICE AND TECHNICAL SUPPORT MANUAL
Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate
Table 5 (Cont.)
TO BE USED WITH MODULATING FURNACES (F/G)9MAE0602120 FURNACE ONLY
(TABULATED DATA BASED ON 20,200 BTUH MAX-HEAT / 8,000 BTUH MIN-HEAT PER BURNER,
ALTITUDE
RANGE
ft (m)
7001
(2134)
to
8000
(2438)
8001
(2439)
to
9000
(2743)
9001
(2744)
to
10000
(3048)
* Orifice numbers shown in BOLD are factory-installed.
16
DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
AVG. GAS
HEAT VALUE
0.58
AT ALTITUDE
Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press
(Btu/cu ft)
No.
Max/Min
650
42
3.4 /0.55
675
42
3.2 /0.50
700
43
3.6 /0.55
725
43
3.4 /0.55
750
44
3.6 /0.55
775
44
3.4 /0.55
800
44
3.2 /0.50
825
46
3.8 /0.60
625
42
3.4 /0.55
650
42
3.2 /0.50
675
43
3.6 /0.55
700
44
3.8 /0.60
725
44
3.6 /0.55
750
44
3.3 /0.50
775
45
3.8 /0.60
600
42
3.4 /0.55
625
43
3.8 /0.60
650
43
3.5 /0.55
675
44
3.8 /0.60
700
44
3.5 /0.55
725
44
3.3 /0.50
Specifications subject to change without notice.
SPECIFIC GRAVITY OF NATURAL GAS
0.60
0.62
No.
Max/Min
No.
Max/Min
42
3.6 /0.55
42
3.7 /0.60
42
3.3 /0.50
42
3.4 /0.55
43
3.7 /0.60
42
3.2 /0.50
43
3.5 /0.55
43
3.6 /0.55
44
3.7 /0.60
43
3.4 /0.55
44
3.5 /0.55
44
3.6 /0.55
44
3.3 /0.50
44
3.4 /0.55
45
3.7 /0.60
44
3.2 /0.50
42
3.5 /0.55
42
3.7 /0.55
42
3.3 /0.50
42
3.4 /0.55
43
3.7 /0.60
43
3.8 /0.60
43
3.4 /0.55
43
3.6 /0.55
44
3.7 /0.60
44
3.8 /0.60
44
3.4 /0.55
44
3.5 /0.55
44
3.2 /0.50
44
3.3 /0.50
42
3.5 /0.55
42
3.6 /0.55
42
3.2 /0.50
42
3.3 /0.55
43
3.6 /0.55
43
3.8 /0.60
43
3.4 /0.55
43
3.5 /0.55
44
3.6 /0.55
44
3.7 /0.60
44
3.4 /0.55
44
3.5 /0.55
Gas Furnace: (F/G)9MAE
0.64
No.
Max/Min
42
3.8 /0.60
42
3.5 /0.55
42
3.3 /0.50
43
3.7 /0.60
43
3.5 /0.55
44
3.7 /0.60
44
3.5 /0.55
44
3.3 /0.50
42
3.8 /0.60
42
3.5 /0.55
42
3.2 /0.50
43
3.7 /0.55
43
3.4 /0.55
44
3.7 /0.55
44
3.4 /0.55
42
3.8 /0.60
42
3.5 /0.55
42
3.2 /0.50
43
3.6 /0.55
44
3.8 /0.60
44
3.6 /0.55
L11F100B
440 04 4700 00