ICP G9MAE0601714A Service And Technical Support Manual page 15

Modulating, variable speed blower motor 35” tall, high efficiency condensing gas furnace
Table of Contents

Advertisement

SERVICE AND TECHNICAL SUPPORT MANUAL
Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate
Table 5
TO BE USED WITH MODULATING FURNACES (F/G)9MAE0602120 FURNACE ONLY
(TABULATED DATA BASED ON 20,200 BTUH MAX-HEAT / 8,000 BTUH MIN-HEAT PER BURNER,
ALTITUDE
RANGE
ft (m)
0
(0)
to
2000
(610)
U.S.A.
2001 (611)
to
3000 (914)
Canada
2001 (611)
to
4500 (1372)
3001
(915)
to
4000
(1219)
4001
(1220)
to
5000
(1524)
5001
(1525)
to
6000
(1829)
6001
(1830)
to
7000
(2133)
440 04 4700 00
DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
AVG. GAS
HEAT VALUE
0.58
AT ALTITUDE
Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press
(Btu/cu ft)
No.
Max/Min
900
42
3.2 /0.50
925
43
3.7 /0.55
950
43
3.5 /0.55
975
44
3.8 /0.60
1000
44
3.6 /0.55
1025
44
3.4 /0.55
1050
44
3.3 /0.50
1075
45
3.8 /0.60
1100
46
3.8 /0.60
800
42
3.4 /0.55
825
42
3.2 /0.50
850
43
3.7 /0.60
875
43
3.5 /0.55
900
44
3.8 /0.60
925
44
3.6 /0.55
950
44
3.4 /0.55
975
44
3.2 /0.50
1000
45
3.7 /0.60
775
42
3.4 /0.55
800
42
3.2 /0.50
825
43
3.6 /0.55
850
43
3.4 /0.55
875
44
3.7 /0.60
900
44
3.5 /0.55
925
44
3.3 /0.50
950
45
3.8 /0.60
750
42
3.3 /0.50
775
43
3.8 /0.60
800
43
3.6 /0.55
825
44
3.8 /0.60
850
44
3.6 /0.55
875
44
3.4 /0.55
900
44
3.2 /0.50
925
45
3.7 /0.60
725
42
3.3 /0.50
750
43
3.7 /0.60
775
43
3.5 /0.55
800
44
3.8 /0.60
825
44
3.5 /0.55
850
44
3.3 /0.50
875
45
3.8 /0.60
900
46
3.8 /0.60
675
42
3.5 /0.55
700
42
3.2 /0.50
725
43
3.7 /0.60
750
43
3.4 /0.55
775
44
3.7 /0.60
800
44
3.5 /0.55
825
44
3.2 /0.50
850
45
3.7 /0.60
Specifications subject to change without notice.
SPECIFIC GRAVITY OF NATURAL GAS
0.60
0.62
No.
Max/Min
No.
Max/Min
42
3.3 /0.50
42
3.4 /0.55
43
3.8 /0.60
42
3.2 /0.50
43
3.6 /0.55
43
3.7 /0.60
43
3.4 /0.55
43
3.5 /0.55
44
3.7 /0.60
44
3.8 /0.60
44
3.5 /0.55
44
3.6 /0.55
44
3.4 /0.55
44
3.5 /0.55
44
3.2 /0.50
44
3.3 /0.50
45
3.7 /0.60
44
3.2 /0.50
42
3.5 /0.55
42
3.7 /0.55
42
3.3 /0.50
42
3.4 /0.55
43
3.8 /0.60
42
3.2 /0.50
43
3.6 /0.55
43
3.7 /0.60
43
3.4 /0.55
43
3.5 /0.55
44
3.7 /0.60
44
3.8 /0.60
44
3.5 /0.55
44
3.6 /0.55
44
3.3 /0.50
44
3.4 /0.55
44
3.2 /0.50
44
3.3 /0.50
42
3.5 /0.55
42
3.6 /0.55
42
3.3 /0.50
42
3.4 /0.55
43
3.7 /0.60
42
3.2 /0.50
43
3.5 /0.55
43
3.6 /0.55
44
3.8 /0.60
43
3.4 /0.55
44
3.6 /0.55
44
3.7 /0.60
44
3.4 /0.55
44
3.5 /0.55
44
3.2 /0.50
44
3.4 /0.55
42
3.4 /0.55
42
3.6 /0.55
42
3.2 /0.50
42
3.3 /0.50
43
3.7 /0.60
43
3.8 /0.60
43
3.5 /0.55
43
3.6 /0.55
44
3.7 /0.60
43
3.4 /0.55
44
3.5 /0.55
44
3.6 /0.55
44
3.3 /0.50
44
3.4 /0.55
44
3.2 /0.50
44
3.3 /0.50
42
3.4 /0.55
42
3.5 /0.55
42
3.2 /0.50
42
3.3 /0.50
43
3.6 /0.55
43
3.7 /0.60
43
3.4 /0.55
43
3.5 /0.55
44
3.7 /0.55
44
3.8 /0.60
44
3.4 /0.55
44
3.6 /0.55
44
3.3 /0.50
44
3.4 /0.55
45
3.7 /0.60
44
3.2 /0.50
42
3.6 /0.55
42
3.7 /0.60
42
3.3 /0.50
42
3.5 /0.55
43
3.8 /0.60
42
3.2 /0.50
43
3.5 /0.55
43
3.7 /0.55
44
3.8 /0.60
43
3.4 /0.55
44
3.6 /0.55
44
3.7 /0.60
44
3.4 /0.55
44
3.5 /0.55
44
3.2 /0.50
44
3.3 /0.50
Gas Furnace: (F/G)9MAE
0.64
No.
Max/Min
42
3.5 /0.55
42
3.3 /0.50
43
3.8 /0.60
43
3.6 /0.55
43
3.5 /0.55
44
3.8 /0.60
44
3.6 /0.55
44
3.4 /0.55
44
3.3 /0.50
42
3.8 /0.60
42
3.6 /0.55
42
3.3 /0.55
43
3.8 /0.60
43
3.6 /0.55
43
3.4 /0.55
44
3.7 /0.60
44
3.6 /0.55
44
3.4 /0.55
42
3.7 /0.60
42
3.5 /0.55
42
3.3 /0.50
43
3.8 /0.60
43
3.6 /0.55
43
3.4 /0.55
44
3.6 /0.55
44
3.5 /0.55
42
3.7 /0.55
42
3.4 /0.55
42
3.2 /0.50
43
3.7 /0.60
43
3.5 /0.55
44
3.8 /0.60
44
3.6 /0.55
44
3.4 /0.55
42
3.6 /0.55
42
3.4 /0.55
42
3.2 /0.50
43
3.6 /0.55
43
3.4 /0.55
44
3.7 /0.60
44
3.5 /0.55
44
3.3 /0.50
42
3.8 /0.60
42
3.6 /0.55
42
3.3 /0.50
43
3.8 /0.60
43
3.5 /0.55
44
3.8 /0.60
44
3.6 /0.55
44
3.4 /0.55
L11F100A