Regency Fireplace Products GFI300LNG-R Owners & Installation Manual page 16

Gfi300l series gas inbuilt
Table of Contents

Advertisement

INSTALLATION
13. Reinstall new burner orifi ce LPG stamped #53 or ULPG burner orifi ce
stamped #55 and tighten.
14. Install new LP burner supplied with kit ensuring aeration is set to 13mm
for LPG or fully open for ULPG - prior to install.
15. Replace the yellow "NG" label with the red "ULPG" label.
16. Carefully pull out the control box.
NOTE: The control box is held in place with velcro.
17. Remove the heat shield from the control box by removing the 2 screws.
18. Remove the control box cover by undoing the 3 screws.
Manoeuvre through antenna.
19. Remove the jumper using pliers and discard.
Jumper
20. Reverse Steps 18,17,16,14,8,7,6, and 5.
21. Turn on gas supply and plug in power cord.
22. Adjusting the Outlet Pressure
All the adjustments must be carried out in the following order:
Installer Notice:
These instructions must be left
with the appliance.
16
Antenna
Control Box
Cover
Jumper Location
Remove the modulator plastic cap (A) using needle nose pliers.
Maximum pressure: Turn the unit ON to its highest input rating. Screw
in the nut (B) to increase the outlet pressure and screw it out to decrease
it. Use a 10 mm wrench.
NOTE: The outlet pressure must be set to maximum 2.3 kPa.
Minimum pressure: Remove one of the cables connected to the electric
modulator. While holding the nut (B) with a wrench, screw in the screw (C)
to increase the pressure and screw it out to decrease it. Use a screwdriver
6 x 1 blade.
After carrying out all adjustments, block the setting screws with
paint, taking care not to obstruct the breather orifi ce of the pres-
sure.
Put back the modulator plastic cap.
WARNING: To ensure the correct operation of the modulator it is
necessary that the plastic cap (A) is returned to its original loca-
tion.
NOTE: The outlet pressure must be set to minimum 1.5 kPa.
B
23. Reverse Steps 10,4,3,2 and 1.
24. At the end of all setting and adjustment operations, check electrical
installation and gas leaks.
24. Check operation of fl ame control.
25. Check for proper fl ame appearance and glow on logs.
Cable
Electric
Modulator
A
C
Regency GFI300L Gas Fireplace Inbuilt

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gfi300llp-rGfi300lulpg-r

Table of Contents