Mega 64 Profile Plus
DMX State:
This mode can be used as a precaution mode, that in case the DMX
signal is lost, the operating mode chosen in the setup is the running
mode the fixture will go into when the DMX signal is lost. You can also
set this as the operating mode you would like the unit to return to when
power is applied.
1. Plug the fixture in and press the MODE button until "d.XXX" is dis-
played. "XXX" represents the current displayed DMX address.
2. Press the SET UP button so that "nodn" is displayed. Use the UP
and DOWN buttons to scroll through the DMX states.
• "bLAC" (Blackout) - If the DMX signal is lost or interrupted,
the unit will automatically go into stand by mode.
• "LASt" (Last State) - If the DMX signal is lost or interrupted,
the fixture will stay in the last DMX set up. If power is applied and
this mode is set, the unit will automatically go into the last DMX set
up.
• "ProG" (Auto Run) - If the DMX signal is lost or interrupted,
the unit will automatically go into Auto Run mode.
3. Use the UP and DOWN buttons to find your desired DMX state
and press SET UP to confirm and exit.
Dimmer Curve Setting:
1. Plug the fixture in and press the MODE button until "d.XXX" is dis-
played. Now press the SET UP button until "dr-X" is displayed,
"X" representing a number between 0-4.
2. There are 5 dimmer curve settings to choose from. Please see the
Dimmer Curve Diagram Chart on page 23 to see the settings and
their respective beginning and ending fade times.
Default Running Mode:
This is a default running mode. When this mode is activated all modes
will return to their default settings.
1. Plug the fixture in and press the MODE button until "dXX" is dis-
played. "XX" represents either "on" or "oFF".
2. Press the SET UP button until "dEFA" is displayed.
3. Press the UP and DOWN buttons simultaneously. Press the MODE
button to exit.
ADJ Products, LLC - www.adj.com - Mega 64 Profile Plus User Manual Page 10
Operating Instructions
Mega 64 Profile Plus
ADJ LED RC:
This function is used to activate and deactivate the ADJ LED RC
(Remote Control). When this function is activated you can control the
fixture using the ADJ LED RC. Please see the next page for ADJ LED
RC controls and functions.
1. Plug the fixture in and press the MODE button until "dXX" is dis-
played. "XX" represents either "on" or "oFF".
2. Press the SET UP button until "IrXX" is displayed. "XX" represents
either "on" or "oF".
3. Press the UP or DOWN buttons to either activate the remote func-
tion (On) or deactivate it (Off).
Mega 64 Profile Plus
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-
Slave set-up. In a Master-Slave set-up one unit will act as the controlling
unit and the others will react to the controlling units built-in programs.
Any unit can act as a Master or as a Slave however, only one unit can be
programmed to act as the "Master."

Master-Slave Connections and Settings:

1. Daisy chain your units via the XLR connector on the rear of the unit.
Use standard XLR data cables to link your units together. Remember
that the Male XLR connector is the input and the Female XLR con-
nector is the ouput. The first unit in the chain (master) will use the
female XLR connector only. The last unit in the chain will use the
male XLR connector only.
2. Connect the first "Slave" unit to the "Master."
3. Set the "Master" unit to your desired mode of operation. Set the
"Slave" unit(s) to the DMX address setting.The "Slave" unit(s) will now
follow the "Master".