Decorative Gas Fireplaces THE “A” SERIES Standard Insulated Heatmaster Decorative Gas Fireplace Installation Guide Heatmaster National Office 2/9 Nicole Close Bayswater Victoria 3153 Phone: 03 9761 7130 Fax: 03 9761 7134 Heatmaster NSW, Qld, ACT 2/16 lexington drive, Northwest Business Park, Bella Vista NSW 2153 Phone: 02 8824 9122 Fax: 8824 6487 www.heatmaster.com.au...
Page 2
100 x 50 Fig 1B on edge Fig 1B - Min. Framing Dimensions on Non-combustible floor If installing onto combustible material, Heatmaster recommend 10mm cement sheeting underneath unit. Please take this into account when framing. Model No A450 A650...
STEP 2 STEP 3 Step two. Install selected insulated "A series" Heatmaster unit along Fig 2B - Heatmaster firebox gas pipe location with flues (see Flue detail diagram fig 3A). Insert gas unit using a qualified Gas Plumber. (For full gas specifications...
Page 4
Flue details Fluing your Heatmaster Gas fireplace The Heatmaster double skin flue kit, into timber and plaster must have clearance of 25mm from any combustible material. Be sure the inner flue crimped end faces down while the outer flue crimped end faces up. The first and last length of flue must have ventilation holes, these cool the flue down by allowing air to travel in between the two skins.