Operating Instructions - Five Seasons 790AI Owner's Manual

Electronic air cleaner and ionizer

Advertisement

BENEFITS
Helps provide relief from allergy, asthma and respiratory
illness.
Helps clear a smokey environment quickly, so everyone
can work and relax together.
Helps reduce the time and money spent cleaning and
redecorating.
Prevents damaging black dust from
staining walls, upholstery and window coverings.
Improves indoor air quality for a fresher, more
comfortable environment, year-round.
HOW IT WORKS
1 Dirty Air
2 Prefilter
3 Charging
Section
Dirty air is drawn in through the front grill and passes through
a 4-Stage filtering system.
The Prefilter is constructed of aluminum mesh. It prevents
larger particles from entering the collecting cell.
The next step is a 2-Stage Electrostatic Collecting Cell. The
dirt particles are charged with a high positive voltage by a
series of fine ionizing wires. The charged particles are drawn
through to the collecting plates where the dirt adheres to the
grounded plates and remains until the cell is taken out and
washed.
Removes
particles
(1/2,540,000 of an inch).
The air is then drawn through an Activated Carbon Filter to
remove odors. Clean air is then discharged out the top and
back of the Air Cleaner.
A negative ionizer needle is located in the clean air stream.
Adding negative ions to the air revitalizes the air similar to
that near a waterfall, spring, the ocean, or after a rainfall.
Studies have shown that negative ions have a beneficial
effect on human biochemistry, both physically and mentally.

OPERATING INSTRUCTIONS

1.
Lean Air Cleaner on side panel and pull out of box. If
your unit has any signs of damage, immediately contact
the store where the Air Cleaner was purchased.
2.
Keep the shipping carton and packaging in case the
need arises to store or transport the unit.
3.
Remove all packaging from the unit. Choose a suitable
location to allow unobstructed circulation from front, top
and back of unit. The unit performs best when the back
is against a wall. This enhances air circulation. Allow at
least one inch (2.5 cm) away from back wall.
4.
Operate Air Cleaner at voltage shown on back of unit.
4 Collecting Cell
Plates
5 Carbon Filter
7 Negative Ions
and Clean Air
6 Ionizing Needle
down
to
0.01
micron
5.
The controls for the Air Cleaner are located under the
hinged cover on the top of the unit. To turn the Air
Cleaner on, push the System Switch to the ON position.
This controls the power to the Fan Speed Switch and to
the power board. When the Fan Speed Switch is in the
extreme left position, the fan is on low; center position is
medium; and to the right is high speed.
System Switch is turned ON, the green Performance
Indicator Light should be illuminated.
Use the low or medium speed for quiet, continuous or
nighttime use.
Use the high speed for initial cleaning of
heavy concentrations of dirty air (i.e. smoke) or after leaving
the room.
6.
When the System Switch is ON and the power board is
working, the Performance Light should be illuminated.
The negative ionizer is on when the System Switch is
ON. Note: The Negative Ion Emitter will not work
without the System Switch being ON.
You may notice arcing or snapping from the cell. It is normal
to hear some arcing when the unit is new or first turned on.
Arcing in the cell may also be caused by high humidity (over
80%), after washing, or when a large particle of dirt or hair is
caught in the cell. If the arcing is continuous and constant,
then refer to the Troubleshooting Chart.
Low Speed
OFF
ON
System Switch
Fan Speed Switch
When the
Medium Speed
High Speed
Carbon Filter
Collecting Cell
Air Flow Direction Arrow
Red Fibreboard Contact
Prefilter
Access Door