BENEFITS
Helps provide relief from allergy, asthma and respiratory
illness.
Helps clear a smokey environment quickly, so everyone
can work and relax together.
Helps reduce the time and money spent cleaning and
redecorating.
Prevents damaging black dust from
staining walls, upholstery and window coverings.
Improves indoor air quality for a fresher, more
comfortable environment, year-round.
HOW IT WORKS
1 Dirty Air
2 Prefilter
3 Ionizing
Section
Dirty air is drawn in through the front grill and passes through
a 4-stage filtering system.
The Prefilter consists of aluminum mesh and foam.
prevents larger particles from entering the collecting cell.
The next step is a 2-Stage Electrostatic Collecting Cell. Dirt
particles are charged with a high positive voltage by a series
of fine ionizing wires.
The charged particles are drawn
through to the collecting plates where the dirt adheres to the
grounded plates, and remains until the cell is taken out and
washed.
Removes
particles
(1/2,540,000 of an inch).
The air is then drawn through an Activated Carbon Filter to
remove odours (included with Model 585AI-BLK), or an
Activated Carbon/Potassium Permanganate Volatile Organic
Compound (VOC) Filter to remove noxious odours and gases
(included with Model 585AI-2-W).
discharged out the top of the Air Cleaner.
A negative ionizer needle, controlled by a separate switch, is
located in the clean air stream. Adding negative ions to the
air revitalizes the air similar to that near a waterfall, spring,
the ocean, or after a rainfall.
negative
ions
have
a
biochemistry, both physically and mentally.

OPERATING INSTRUCTIONS

1.
Remove the Air Cleaner from the box and check for
apparent damage. If your unit has any signs of damage,
immediately contact the store where the Air Cleaner was
purchased.
2.
Keep the shipping carton in case the need arises to
store or transport the unit.
3.
Remove all packaging from the unit. Choose a suitable
table or stand to allow unobstructed circulation from front
and top of unit. The unit performs best when the back is
against a wall. This enhances air circulation. To mount
unit on wall, refer to the Wall Mount Instructions.
4.
Operate Air Cleaner at voltage shown on back of unit.
4 Collecting Cell
Plates
5 Odour & Gas
Filter
7 Negative Ions
and Clean Air
6 Ionizing Needle
down
to
0.01
micron
Clean air is then
Studies have shown that
beneficial
effect
on
human
5.
The System Switch controls the power to the Fan
Control Switch and the power board. When the System
Switch is ON, the green light will be illuminated.
6.
The Fan Control Switch in the front position is low
speed, the center position is medium, and the rear
position is high speed.
Use the low or medium speed for quiet, continuous or nighttime use.
Use the high speed for initial cleaning of heavy concentrations of dirty
air (i.e. smoke) or after leaving the room.
7.
The negative ions are controlled by a separate switch
located beside the System Switch. When the switch is
It
ON, the red light will be illuminated.
Negative Ion Emitter will not work without the
System Switch being ON.
You may notice arcing or snapping from the cell. It is normal
to hear some arcing when the unit is new or first turned on.
Arcing in the cell may also be caused by high humidity (over
80%), after washing, or when a large particle of dirt or hair is
caught in the cell. If the arcing is continuous and constant,
then refer to the Troubleshooting Chart.
WALL MOUNT INSTRUCTIONS
1.
To mount Air Cleaner on wall, remove the rear feet (2)
from the bottom of the Air Cleaner, to expose the
keyhole slots.
2.
To remove the feet from the Air Cleaner, you will need a
small, flat screwdriver. Pry up the center pin of the rear
foot until the head protrudes above the foot. Place the
flat portion of the screwdriver under the foot and pry up.
This will release the foot from the cabinet. Keep the feet
in case you wish to table mount the unit in future.
3.
Find the location on the wall where you wish to place the
Air Cleaner. The unit should be placed 3 feet (1 m)
below the ceiling. Use appropriate fasteners for the type
of wall the unit will be mounted and insure the head of
the screw will fit into the larger opening of the keyhole
slot. The screw head should be larger than the smaller
opening of the keyhole.
approximately 20 lbs (9 kg). The distance between the
holes in the cabinet bottom is 16 15/16 in (43 cm).
4.
After placing the screws in the wall, adjust the amount of
the screw sticking out to approximately 1/8 in (.32 cm).
Place the Air Cleaner over the screw head and allow the
head to slip into the keyhole slot. Pull the unit down
slightly to allow the screw head to slide into the smaller
portion of the slot.
1 - System Switch
2 - Negative Ion Control Switch
3 - 3-Speed Fan Control Switch
4 - Negative Ion Emitter
5 - Lid which activates Safety Interlock
The Air Cleaner weighs
5
4
3
2
1
Note: