Electronic air cleaner and ionizer

Advertisement

CLEANING INSTRUCTIONS
The prefilter and collecting cell must be washed on a regular
basis for the Air Cleaner to function at its peak efficiency.
The frequency of cleaning will vary from one environment to
another, therefore the cell should be checked monthly to
determine cleaning schedule. On average, the cell should be
washed every 2-3 months.
COLLECTING CELL AND PREFILTER
1.
Turn Air Cleaner OFF. Remove prefilter and collecting
cell from the Air Cleaner.
2.
Rinse prefilter and cell, and spray completely with DAX
Detergent (or non-chlorine, non-corrosive, non-abrasive,
non-ammonia, liquid household detergent). Let stand for
5 minutes.
Rinse well with hot water (120°F / 49°C
maximum). Repeat process 3 times.
3.
If dirt remains, let cell soak in a solution of DAX
Detergent and hot water for 30 minutes.
4.
For drying, place the cell on a 45° angle on one end,
with the arrow pointing sideways, and let stand for 10-24
hours. A hair dryer may be used to speed up drying
time.
Make sure the cell is completely dry before
reinserting back into Air Cleaner.
5.
If arcing or snapping occurs or the lights do not come on
when the cell is placed back in the unit and turned on,
then remove the cell and allow to dry longer.
CARBON FILTER
1.
The carbon filter must be replaced at regular intervals if
odor removal is desired (approximately every 3-6
months).
ODOR REMOVAL FILTERS ARE NOT WASHABLE.
CABINET
1.
Turn Air Cleaner OFF.
2.
A soft, damp, lint-free cloth may be used to remove dirt
and fingerprints from painted surfaces, grills and side
panels.
NEVER USE AN ABRASIVE CLEANER ON THE
CABINET.
WARNING
DO
NOT
WASH
DISHWASHER.
Never use any object to clean between the cell plates as
this may cause damage to the plates or ionizing wires.
Never place the cell in an oven to dry.
The edges of the cell may be sharp — handle with care.
DAX Detergent and Carbon Filters are available from your Dealer.
COLLECTING
CELL
TROUBLESHOOTING CHART
PROBLEM
Fan does not operate
Performance Light off
Fan does not operate
Performance Light on
Fan operating
Performance Light off
Cell arcing excessively
The Performance Indicator Light is also used as the high
voltage fault indicator. If the fan is operating, but the light
does not come on, then there is a problem in the high voltage
circuit. To determine the problem, turn the Air Cleaner OFF
and remove the collecting cell. Close the door and turn the
Air Cleaner back ON. If the light comes back on, the problem
lies in the cell. Check the cell for wetness from washing or
look for a broken ionizing wire or bent cell plate(s).
If the Performance Light does not come on, the problem is
with the power board or Performance Light. If you are unable
to correct any of the above problems, call toll free North
A m e r i c a
1 - 8 0 0 - 2 6 7 - 8 3 0 5
info@fiveseasonsaircleaners.com.
Dimensions
Length
Width
IN
Height
Weight
Input Voltage
Power
Consumption
(maximum)
Air Flow
High
Medium
Low
Cell Output Voltage
Collecting Cell
Surface
Negative Ionizer
Negative Ion
Output
Ideal for rooms up
to: (for over 3 air
changes/hour)
CAUSE
Unit not plugged in
Cell access door not closed
tightly
System switch not ON
Speed selector switch not
positioned correctly
Fan motor malfunction
Cell wet from washing
Short in cell (see below)
Cell wet from washing
Cell plate(s) bent
Cell dirty or large lint ball/hair
caught in cell
Broken ionizing wire
o r
e m a i l
TECHNICAL DATA
13.5 in
12.0 in
27.3 in
40.0 lbs
120 V 60 Hz
220 V
220-240 V 50 Hz
150 Watts
258 cfm
200 cfm
150 cfm
6200 VDC @ < 1 mA
1190 in²
-5000 VDC @ <.1 mA
327.7 K/in³
23 x 28 x 8 ft
7.0 x 8.5 x 2.5 m
644 ft²
u s
a t
34.3 cm
30.5 cm
69.3 cm
18.0 kg
60 Hz
439 m³/hr
340 m³/hr
255 m³/hr
7676 cm²
20 K/cm³
59.0 m²