Self-Diagnostic Screen Display; Handling Of Self-Diagnostic Screen Display - Sony KP-FS43M90 Service Manual

Table of Contents

Advertisement

1-4. SELF-DIAGNOSTIC SCREEN DISPLAY

For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confirmed, it is possible
to bring up past occurrences of failure for confirmation on the screen:
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
(
ON SCREEN
DISPLAY
Self-Diagnosis screen display
SELF DIAGNOSTIC
002:000
003:000
004:000
005:001
006:002
007:000
101:000

1-5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY

Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen
during repairs. When you have completed the repairs, clear the result display to "0".
Unless the result display is cleared to "0", the self-diagnostic function will not be able to detect subsequent faults after completion of
the repairs.
[Clearing the result display]
To clear the result display to "0", press button on the remote commander sequentially as shown below when the diagnostic screen is
being displayed.
Press "8" button
(It will indicate "CLEAR" on the screen.)
[Quitting Self-diagnostic screen]
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
5
)
(DIGIT 5)
*
(VOLUME –)
* : Note that this differs from entering the service mode (volume +)
Numeral "0" means that no fault has been detected.
Numeral "1" means a fault has been detected.
Numeral "2" means two faults have been detected.
,
(POWER)
Press "-" button
(The "CLEAR" display change to red color.)
– 7 –
KP-FS43M90/FS53M90
RM-998
RM-998

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kp-fs53m90

Table of Contents