The display shows the software version in six digits/symbols divided into three parts.
e.g. Ver. 9-3-6 = "09", "-3", "-6"
The indication is repeated until the maintenance A button is released.

[d] DISPLAYING ERROR LOG

Press and hold the maintenance A button, and press the stop button. The display shows the
following items one by one every time the stop button is pressed.
This function is available in the ice or stop mode.
Press and hold MAINTENANCE A
Compressor operating hours on display -------- [c] a)
Press STOP
Error log on display (8 records at maximum)
Press STOP
"- -" on display (end of error log display mode)
Press STOP
Ongoing error on display
Release MAINTENANCE A
Note:
1. The display does not show the ongoing error even if the stop button is pressed while the
error log is in the display. To display the ongoing error, press the stop button while "- -" is
in the display to show the end of the error log display mode