CREATING A "SIDEWAYS" FLUE INSTALLATION

b
d
Total flue length can be up to 6.5 metres long and can
contain a maximum of one (1) ESBEND (1 x 90°)!
e
a
Follow steps 1 through 5 from the chapter "Heater Installation" in the "Rinnai ASPIRATION Operation / Installation
Manual" supplied with the heater.
The Sideways flue installation can run along the left or right hand side of the internal wall behind the heater. When
considering the location of the heater due care must be taken to ensure that the flue path is free of obstructions
such as studs, noggins, joists, braces, and electricals etc.
To prevent accidental or erroneous dislodgement, the joints between transition assembly (flue
transition and condensate trap assembly) and ESPIPE900 components MUST BE secured by pop
CAUTION
rivet or screw through the outer co-ax pipes and flue pipes are to be clipped to the wall using the
stand off clips supplied or other suitable method.
Steps for creating a Sideways flue installation are as follows:
!
1
The joints between the flue transition and condensate trap MUST BE secured by a pop rivet or
screw through the outer co-ax pipes to prevent accidental or erroneous dislodgement.
CAUTION
The assembled ASPKIT03 is to be clipped using the stand off clips supplied or other suitable
method. ASPKIT03 components and ESPIPE900 DO NOT require cutting to be joined.
2.
Use the section "WALL PENETRATIONS" on page 6 to determine the vertical and horizontal location of the
heater's flue exhaust outlet and mount the assembled ASPKIT03 components in this location, in a horizontal
manner.
Ensure that when the ASPKIT03 is mounted that both the combustion air connection and condensate drain
connection are installed facing upper most.
3. Fit lengths of ESPIPE900 to ASPKIT03 in accordance with "COMPONENT ASSEMBLY & CONNECTION ~
ESPIPE900" on page 17. Determine the location of the wall penetration points.
The joint between ASPKIT03 and ESPIPE900 MUST BE secured by a pop rivet or screw through
the outer co-ax pipes and flue pipes are to be clipped to the wall using the stand off clips supplied
CAUTION
or other suitable method.
ASPKIT03 and ESPIPE900 DO NOT require cutting to be joined.
Rinnai Australia
FLUE COMPONENT ASSEMBLY
1.1.1. Assemble the Flue Adaption Kit 750 (ASPKIT03) joining the flue transition and the
condensate components together.
connection of the flue transition and the condensate drain connection of the
condensate trap are aligned with each other, then secure the components together
in accordance with "COMPONENT ASSEMBLY & CONNECTION ~ ESCONDK" on
page 19.
Activities for creating a Sideways flue installation:
a.
Assemble Flue Adaption Kit 750 (ASPKIT03).
b.
Locate, Fit & Secure ASPKIT03 components.
y
c.
Locate Heater.
d.
Connect Heater Exhaust.
e.
Connect Combustion Air Hose.
f.
Cut, Fit & Secure Components (As Required).
y.
Refer to steps e. & f. of Creating Direct / Creating
Direct Extended Flue Installations (As Required).
z.
Finalise Installation & Commissioning Of Heater.
f
c
13
CAUTION
CAUTION
ensure that both the combustion air
ASP Flue Installation Manual
?
CAUTION