SIRe Basic Fan Heaters Electric Quick guide/start up Enter ID/Operation without control unit The control system can control one or more Check that all constituent parts are present units in parallel (max 9). Each unit must get (see section Constituent parts). a unique ID number (1-9) which is set in the ID selector of the PC board.
SIRe Basic Fan Heaters Electric Start up System supplied with power. Three digits 1.4.0. (software version) is quickly shown in th the status window followed by three horizontal lines. After about 30 seconds the prevailing room temperature is then shown in the status window.
SIRe Basic Fan Heaters Electric Contents Quick guide/start up Advice about location Connect the system Wiring diagrams Enter ID/Operation without control unit Start up Constituent parts SIReBX Option Max. cable lenghts Operating modes Operating modes Fan over run Heat regulation Set values System on/off...
SIRe Basic Fan Heaters Electric Constituent parts SIReBX SIReB1X, External SIReIT02, internal SIReUB1, Wall unit PC board Basic temperature sensor control unit Basic cover SIReCC, modular cables Dimensions constituent parts Type Description HxWxD [mm] SIReUB1 Control unit 120x70x35 SIRB1X PC Board Base...
SIRe Basic Fan Heaters Electric Operating modes Set values Use arrow up /down to choose desired room Operating modes temperature, fan speed step and heating step. Factory settings gives manual control of fan and heating controlled by thermostat at choosen step. Fansteps Heatsteps Push the confirm button and the digit(s)
SIRe Basic Fan Heaters Electric Control unit SIReUB1 Overview Prevailing room temperature Statuswindow 2 0 8 Arrow up Scroll up Confirm Desired room Arrow down temperature Scroll down Fan speed step Alarm Red led Run signal Green led ON/OFF button Heating step Explanations Confirm...
SIRe Basic Fan Heaters Electric Installer menu Parameter menu P .01 Overheating alarm ON/OFF Keep Confirm button pressed until P00 is Possibility to block the alarm (only valdid for shown in the status window. Use arrow up / units with internal temperature sensor). down to scroll between the parameters.
Frico. Displaying alarm and error codes In event of alarm or error the alarm/error code and the unit it applies to is shown in the...
Page 11
Fault on or missing internal sensor in Check connection of the sensor. If there error the unit (applies to units with internal is no sensor, contact Frico for support. sensor). E.ru Room sensor Fault on internal room sensor in the...
Page 12
SIRe Basic Fan Heaters Electric Connections between SIReB1X and Panther SE06, SE09, SE12 and SE15. SIReB1X SE06-15...
Page 13
SIRe Basic Fan Heaters Electric Connections between SIReB1X and Panther SE20 SIReB1X SE20...
Page 14
SIRe Basic Fan Heaters Electric Connections between SIReB1X and Panther SE30 SIReB1X SE30...
Page 15
SIRe Basic Fan Heaters Electric Wiring diagrams Basic...
Page 16
SIRe Basic Fan Heaters Electric Wiring diagram Basic parallel SIReB1X Pot. Pot. Unit ID Unit ID ≠ SIReRTX SIReB1 ROOM Pot. Unit ID SIReUB1 ACTUATOR SUPPLY N L~ L SIReB1 ROOM Pot. Unit ID ACTUATOR SUPPLY N L~ L...