Start up

System supplied with power. Three digits
1.4.0. (software version) is quickly shown
in th the status window followed by three
horizontal lines. After about 30 seconds the
prevailing room temperature is then shown in
the status window.
After the first start up the following basic
settings are made. Use arrow up/down and set
the desired room temperature, fan speed step
and heating step. To change a setting push
the round button (confirm), the setting will
start to flash and can be adjusted by using the
arrow up/down.
Factory settings gives manual control of
fan and heating controlled by thermostat.
For more setting alternatives see section
Operating modes.
At the first start up alarm and error codes
can occur, these can usually be reset without
action.
Fansteps
SE06-15
4
SE20
2
SE30
2
Choose desired room
temperature 5 - +30 °C
Choose fan step 1-5 (alt.
1-3)
Activate heat
0 = No heat
1 = Heat step 1 possible
2 = Heat step 2 possible
(3 = Heat step 3 possible)
Heat steps controlled by
thermostat
12
SIRe Basic Fan Heaters Electric
Heatsteps
2
2
3
C
2 0
-
3
_
2

Advertisement

Table of Contents
loading