Installer menu

Parameter menu

Keep Confirm button pressed until P00 is
shown in the status window. Use arrow up /
down to scroll between the parameters. Press
Confirm button once to change a setting in
the parameter menu. Flashing values can be
adjusted using the arrow up/down and then
confirm. Keep the Confirm button pressed
to return to the status window. (Returning
automatically to the status window after
about 50 seconds).
P 0 0
.
P 0 1
.
P 0 2
.
P 0 2
.
P 0 2
.
P 0 2
.
P 0 2
.
P 0 2
.

Parameter description

P .00 Temperature difference heating steps
Sets the difference between the heating steps.
Factory setting of 1,0 and a desired room
temperature of 20 °C gives the following
operation:Low heating step is connected
at +19,5 °C (disconnected at +20,0 °C).
If temperature continue to drop below
+18,5 °C another heating step is connected
(disconnected at +19,0 °C), etc.
List of parameters
Parameter-
Description
number
P .00
Temperature difference between heating steps
P .01
Overheting alarma ON/OFF ON=1; OFF=0
P .02
Over run time when heat has been activated
P .03
Temperature limit for fan over run
P .04
Fan control: Manul rorAuto; 0=Manul, 1 = Auto
P .05
Display of unit internal/outlet temperature
P .06
Run time fan step 1
P .07
Run time fan step 2
P .08
Run time fan step 3
P .09
Run time fan step 4
P .10
Run time fan step 5
P .11
Run time heating step 1
P .12
Run time heating step 2
P .13
Run time heating step 1+2
18
SIRe Basic Fan Heaters Electric
P 1 3
.
P .01 Overheating alarm ON/OFF
Possibility to block the alarm (only valdid for
units with internal temperature sensor).
P .02 Over run time
Time when the fan continue to run when the
heat has been activated (only valid for units
with internal temperature sensor).
P .03 Temperature limit for over run
Over run time is cancelled if the internal
temperature drops below this set value (only
valid for units with internal temperature
sensor).
P .04 Fan control
Choose manul (0) or auto (1) mode, read
more under section Operating mode.
P .05 Internal temperature
Prevailing internal temperature. Only the
peak value is shown when several units are
connected (only valid for units with internal
temperature sensor).
P .06 - P .13 Run time
Run time for fan and heating steps.
Setting
range
0,5-10
1/0
10-300
10-40
0/1
0-100
0-99999
0-99999
0-99999
0-99999
0-99999
0-99999
0-99999
0-99999
Factory