Edit Raid - Thecus N8900 series User Manual

Hide thumbs Also See for N8900 series:
Table of Contents

Advertisement

JBOD
RAID 0
RAID 1
RAID 5
RAID 6
RAID 10
RAID 50
RAID 60
WARNING

Edit RAID

On the RAID Information screen, press the Edit button to go to the RAID
Information screen.
Using Edit RAID, you can select RAID ID and the Spare Disk.
The storage volume is a single HDD with no RAID support. JBOD
requires a minimum of 1 disk.
Provides data striping but no redundancy. Improves performance
but not data safety. RAID 0 requires a minimum of 2 disks.
Offers disk mirroring. Provides twice the read rate of a single disk,
but same write rate. RAID 1 requires a minimum of 2 disks.
Data striping and stripe error correction information provided.
RAID 5 requires a minimum of 3 disks. RAID 5 can sustain one
failed disk.
Two independent parity computations must be used in order to
provide protection against double disk failure. Two different
algorithms are employed to achieve this purpose. RAID 6 requires
a minimum of 4 disks. RAID 6 can sustain two failed disks.
RAID 10 has high reliability and high performance. RAID 10 is
implemented as a striped array whose segments are RAID 1
arrays. It has the fault tolerance of RAID 1 and the performance
of RAID 0. RAID 10 requires 4 disks. RAID 10 can sustain two
failed disks.
RAID 50 combines the straight block-level striping of RAID 0 with
the distributed parity of RAID 5. This is a RAID 0 array striped
across RAID 5 elements. It requires at least 6 drives.
RAID 60 combines the straight block-level striping of RAID 0 with
the distributed double parity of RAID 6. That is, a RAID 0 array
striped across RAID 6 elements. It requires at least 8 disks.
If the administrator improperly removes a hard disk that should not be
removed when RAID status is degraded, all data will be lost.
86