N0922L, N1322L, F1222L, F1522L
Remote Low Side Service Manual Includes Prodigy Plus

Component Indicator Lights

The controller has six lights to indicate component
operation:
Bin Eyes Blocked
This light is ON when the photo-electric ice
sensors have been blocked by ice.
Water Present
This light is ON when the water sensor has water
touching it.
Comp
May light but is not used on this model.
Water Dispense
Not used on this model, not present on Prodigy
Plus
Auger
This light is ON when the auger motor is
operating.
Ice Dispense
Not used on this model, not present on Prodigy
Plus
Control Button Use
Recall diagnostic code:
Hold off button in for 3 seconds. Release.
Press and release the Clean button to cycle
through each of the last 10 error codes from most
recent to oldest.
Clear diagnostic code:
Hold Clean and Off buttons in for 3 seconds to
clear all prior codes.
Reset control:
Depress and release Off, then depress and
release On
Start Test Mode:
Hold Off button in for 3 seconds. Release.
Hold Clean button in for 3 seconds. Release.
Lock / Unlock control:
Hold On button in for 3 seconds, keep holding
then press and release Off twice.
December 2014