N0922L, N1322L, F1222L, F1522L
Remote Low Side Service Manual Includes Prodigy Plus
Component Indicator Lights
The controller has six lights to indicate component
operation:
Bin Eyes Blocked
•
This light is ON when the photo-electric ice
sensors have been blocked by ice.
Water Present
•
This light is ON when the water sensor has water
touching it.
Comp
•
May light but is not used on this model.
Water Dispense
•
Not used on this model, not present on Prodigy
Plus
Auger
•
This light is ON when the auger motor is
operating.
Ice Dispense
•
Not used on this model, not present on Prodigy
Plus
Control Button Use
Recall diagnostic code:
•
Hold off button in for 3 seconds. Release.
•
Press and release the Clean button to cycle
through each of the last 10 error codes from most
recent to oldest.
Clear diagnostic code:
•
Hold Clean and Off buttons in for 3 seconds to
clear all prior codes.
Reset control:
•
Depress and release Off, then depress and
release On
Start Test Mode:
•
Hold Off button in for 3 seconds. Release.
•
Hold Clean button in for 3 seconds. Release.
Lock / Unlock control:
•
Hold On button in for 3 seconds, keep holding
then press and release Off twice.
December 2014