Inspections (検査 - Yamaha SP2060 Service Manual

Speaker processor
Hide thumbs Also See for SP2060:
Table of Contents

Advertisement

SP2060
I
INSPECTIONS
1.
Measurement Conditions
1-1.
Environment
• Normal temperature: 5 to 40 degree
• Normal humidity: 30 to 90 %
1-2.
Power Source
The voltage is within ±10 %.
• U
: 120 V
• H
: 230 V
• B
: 230 V
• O
: 230 V
2.
ANALOG Test
The ANALOG test is executed by using the test program.
2-1.
Preparation
Refer to "TEST PROGRAM 1. Preparation" on page 36~37.
2-2.
Measuring conditions
Use following conditions unless otherwise specified.
• 0dBu = 0.775 Vrms
• 0 dBFS = 0 dB, full scale
• Analog output load: 600 Ω
• Cross talk and distortion ratio should be measured with a 80 kHz, -18 dB/octave low pass filter.
• Noise should be measured with a 12.7 kHz, -6 dB/octave low pass filter.
(Use average values instead of effective values for measurement.)
• Oscillator output impedance: 150 Ω.
2-3.
ANALOG Input/Output Test (When WORD CLOCK is INT 96 kHz)
Input analog signal to INPUT A, B terminals and then measure the output signal obtained at OUTPUT 1~6 terminals.
For the details of the measuring procedures, refer to "TEST PROGRAM 3-10. ANALOG Test".
Conditions for each test No. are as shown below.
Test no.
Fs
1
96 kHz
2
96 kHz
Measure the following items by using test No. 1.
1 Gain
Input frequency
1 kHz
2 Frequency Characteristics
Measure the each frequency response compared with the 1 kHz (0 dB).
Input frequency
20 Hz
40 kHz
54
MUTE
OFF
ON
Input level
Specified output level
+4 dBu
Input level
Output level (reference)
+4 dBu
+4 dBu
Variation width
+4 dBu
+4±1 dBu
Variation width
+4 dBu
-1.0~+0.5 dB
+4 dBu
-1.0~+0.5 dB

Advertisement

Table of Contents
loading

Table of Contents