2 Safety

2 Safety

2.1 Safety instructions

2.1.1 Setup and adjustments

Installation and adjustment of the boiler as well as
service maintenance and repair of the boiler may only
be carried out by a competent person in accordance
with the Gas Safety (Installation and Use) Regulations
1998. (In the U.K. "CORGI" Registered installers
undertake the work to a safe and satisfactory standard).
If the boiler is installed in a compartment do not
obstruct any purpose provided ventilation openings, and
do not use the compartment for storage purposes.

2.1.2 If you smell gas

If you smell gas or suspect a gas leak:
• Turn off the boiler
• Do not switch the light or any electrical switches in
the hazardous area on or off, do not use the telephone
in the hazardous area, avoid sparking, such as lighting
the lighter or matches
• Do not smoke in the hazardous area
• Turn off the gas supply at the gas meter
• Ventilate the room
• Warn the other occupants and leave the house
• Consult your gas supplier, service agent or other
competent person.

2.1.3 Modifications in and around the boiler

No modifications may be made to the following items:
• The boiler
• The gas, water and electrical supply
• The flue system
• The safety valve for the heating water
• Any structural changes around the appliance that
could affect the operational safety of the boiler.

2.1.4 Explosive and flammable materials

Do not use or store any explosive or highly flammable
materials (e.g. gasoline, paper or paint) near to the
appliance.

2.1.5 Inspection

The boiler should be serviced annually. We recommend
that you sign a service agreement with your service
agent or Vaillant Ltd.
4
4
Seite 4
Supplied by HeatingSpares247.com

2.2 General precautions

2.2.1 Corrosion protection

DO NOT use aerosol sprays, solvents, chlorine-based
cleaning products, paints, adhesives, etc. in the vicinity
of the unit. The use of these items can, under certain
circumstances, also result in corrosion damage to the
flue outlet system.

2.3 Showers

Only thermostatically controlled showers must be used
with aquaPLUS boilers to guard against the flow of
water at too high a temperature and to ensure constant
shower outlet water temperatures.
Warning!
The appliance is equipped with an automatic
protection function against legionella. If the
temperature in the power store falls below a set
temperature for more than 23 hours the boiler
will operate automatically to thermally disinfect
the store.
Important note!
After completion of the thermal disinfection
process there is a possible risk of scalding when
drawing off hot water.
Hot water temperatures of up to 65 °C are
possible immediately from the tap.
Instructions for use aquaPLUS