2 Safety instructions

2

Safety instructions and regulations

2.1
Safety instructions
2.1.1

Installing and setting the appliance

Important!
The appliance must be installed and serviced by
a competent person as stated in the Gas Safety
(Installation and Use) Regulations 1998. In IE,
the installation must be in accordance with the
current edition of IS 813 ‚Domestic Gas Instal-
lations', the current Building Regulations and
reference should be made to the current ETCI
rules for electrical installation.
2.1.2

Smell of gas

If you smell gas, the following safety instructions should
be observed:
• don't switch on any electrical switch in the danger area,
• don't smoke in the danger area,
• don't use a telephone in the danger area,
• close the gas stop cock,
• air the danger area,
• notify a gas supplier or recognised gas fitting company.
2.1.3

Changes to the surroundings of the boiler

No changes must be made to the following devices:
– the boiler
– the gas, air, water and electricity supply pipes
– the exhaust pipe
– the discharge pipe and the safety valve for the hot
water
– the constructional conditions that could affect the
operational reliability of the device.
2.1.4

Important instructions for propane appliances

Bleeding the liquid gas tank when installing the system:
before installing the device, make sure that the gas tank
has been bled. The liquid gas supplier is responsible for
the proper bleeding of the tank. Ignition problems can
be caused if the tank is not bled properly. In such cases,
first contact the person in charge of filling the tank.
Affixing the tank sticker:
Affix the enclosed tank sticker (propane quality) on the
tank where it is clearly visible or on the bottle cabinet, if
possible close to the filler nozzle.
Installing underground:
When installing in underground places, the requirements
of the TRF 1996 (technical rules for liquid gas) are to be
observed. We recommend the use of an external sole-
noid valve.
6
Connection set for external solenoid valve:
Item no.: 306 253 or 306 248
Danger!
Only propane in accordance with DIN 51622
may be used.
Important!
When tightening or slackening screwed connec-
tions always use suitable open-ended spanners
(not pipe wrenches or extensions etc.).
Incorrect use and/or unsuitable tools can lead
to damage being caused (e.g. gas or water leak-
age)!
2.2

General requirements

2.2.1

Preliminary remarks for roomsealed appliances

This appliance should only be installed in conjunction
with either a Vaillant flue system or an alternative ap-
proved system (details of flue approval categories can be
found in the technical section of the installation manual).
Install the flue system as detailed in the separate flue in-
stallation instructions supplied with this boiler.

2.2.2 Related documents

The installation of the boiler must be in accordance with
the relevant requirements of Gas Safety (Installation
and Use) Regulations 1998, Health and Safety Document
No. 635 (The Electricity at Work Regulations 1989),
BS7671 (IEE Wiring Regulations) and the Water Supply
(Water Fitting) Regulations 1999, or The Water Bylaws
2000 (Scotland). It should also be in accordance with
the relevant requirements of the Local Authority, Build-
ing Regulations, The Building Regulations (Scotland).
The Building Regulations (Northern Ireland) and the
relevant recommendations of the following British
Standards:
BS 6700: Services supplying water for domestic use
within buildings and their curtilages.
BS 6798: Specification for installation of gas fired boil-
ers not exceeding 60 kW input.
BS 6891: Specification for installation of low pressure
gas pipework up to 28 mm (R1) in domestic
premises (2nd family gas).
BS 7593: Treatment of water in domestic hot water cen-
tral heating systems. Institute of Gas Engi-
neers Publication IGE/UP/7/1998: "Guide for
gas installations in timber framed housing"
BS. 5482 Pt. 1 Domestic butane and propane gas burn-
ing installations.
IGE/UP1 Soundness testing and purging of industrial
and commercial gas installation.
IGE/UP2 Gas installation pipework, boosters and com-
pressors on industrial and commercial premises.
IGE/UP10 Installation of gas appliances in industrial and
commercial premises.
BS. 6644 Installation of gas fired hot water boilers of
rated inputs between 60 kW and 2 MW (2nd
and 3rd family gases).
Installation and maintenance manual ecoMAX 646