INSTALLATION

WARNING: To reduce the risk of fire, do not store or use
gasoline or other flammable vapors and liquids in the vicin-
ity of the heater.
CAUTION: High temperature, risk of fire, keep electrical
cords, drapery, furnishings, and other combustibles at least
3 feet (0.9 m) from the front of the heater and away from
the side and rear.
1. Remove housing mask.
Make sure wall has been finished (including paint or wall
paper, etc.) Take out and discard the cardboard mask from
inside of housing.
TABS
2. Install heater assembly into housing.
Place element end of heater assembly behind the tabs on
the left side of housing. Pivot the assembly in and fasten with
retaining screw from parts bag.
Plug wiring harness into receptacle.
3. Provide desired control.
The heater finish assembly has no adjustable thermostat
control.
If a wall-mounted control has been pre-wired, nothing else
need be done.
If a built-in thermostat is desired, purchase and insert the
Broan Model 83 Integral Thermostat at this time.
WIRING
Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
FASTEN TO
HOUSING WITH
RETAINING SCREW -
HERE