TYPICAL INSTALLATION

CEILING
JOIST, TRUSS,
OR I-JOISTS
CEILING
MATERIAL
Housing mounted directly to joists, trusses, or
Up to 4-inches on-center.

PLAN THE INSTALLATION

INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
6-IN.
ROUND
*
DUCT
*
Purchase
6-IN. ROUND
separately
ELBOW(S)
The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number of
elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce
backdrafts.
Plan to supply the unit with proper line voltage and appropriate
power cable.
POWER
MOUNTING
CABLES
CHANNELS
HOUSING
GRILLE
I-joists.
ROOF
CAP
*
INSTALLATION
1. Insert
mounting
brackets.
Slide the (4)
mounting brack-
ets into the chan-
nels on each end
of the housing.
2. Mount hous-
ing.
Secure hous-
ing to ceiling
structure with (4)
mounting screws.
Make sure bottom
of housing will be
flush with finished
ceiling material.
*
3. Attach
damper
/ duct
connector
to housing.
Snap damper /
duct connector
onto housing.
Make sure con-
nector is flush
with top of hous-
ing and damper
flap falls closed.
WALL
*
CAP
4. Install 6-
inch round
ductwork.
Connect 6-inch
round ductwork
to damper / duct
connector. Run
ductwork to a
roof cap or wall
cap. Tape all
ductwork con-
nections to make
them secure and air tight.