Mitsubishi Electric MXZ-2C30VA Service Manual page 267

Outdoor unit
Hide thumbs Also See for MXZ-2C30VA:
Table of Contents

Advertisement

MXZ-6C120VA COOLING
Indoor units
combination
Unit A
15+15+22+22+25+42
1.28
15+15+22+22+25+50
1.21
15+15+22+22+25+60
1.13
15+15+22+22+25+71
1.06
15+15+22+22+35+35
1.25
15+15+22+22+35+42
1.19
15+15+22+22+35+50
1.13
15+15+22+22+35+60
1.07
15+15+22+22+35+71
1.00
15+15+22+22+42+42
1.14
15+15+22+22+42+50
1.08
15+15+22+22+42+60
1.02
15+15+22+22+50+50
1.03
15+15+22+25+25+25
1.39
15+15+22+25+25+35
1.31
15+15+22+25+25+42
1.25
15+15+22+25+25+50
1.18
15+15+22+25+25+60
1.11
15+15+22+25+25+71
1.04
15+15+22+25+35+35
1.22
15+15+22+25+35+42
1.17
15+15+22+25+35+50
1.11
15+15+22+25+35+60
1.05
15+15+22+25+42+42
1.12
15+15+22+25+42+50
1.07
15+15+22+25+42+60
1.01
1.02
15+15+22+25+50+50
15+15+22+35+35+35
1.15
15+15+22+35+35+42
1.10
15+15+22+35+35+50
1.05
15+15+22+35+42+42
1.05
15+15+22+35+42+50
1.01
15+15+22+42+42+42
1.01
15+15+25+25+25+25
1.37
15+15+25+25+25+35
1.29
15+15+25+25+25+42
1.22
1.16
15+15+25+25+25+50
15+15+25+25+25+60
1.09
15+15+25+25+25+71
1.02
15+15+25+25+35+35
1.20
15+15+25+25+35+42
1.15
15+15+25+25+35+50
1.09
15+15+25+25+35+60
1.03
15+15+25+25+42+42
1.10
15+15+25+25+42+50
1.05
1.00
15+15+25+25+50+50
Cooling capacity (kW)
Unit B
Unit C
Unit D
Unit E
1.28
1.87
1.87
2.13
1.21
1.77
1.77
2.01
1.13
1.66
1.66
1.89
1.06
1.55
1.55
1.76
1.25
1.83
1.83
2.92
1.19
1.75
1.75
2.78
1.13
1.66
1.66
2.64
1.07
1.56
1.56
2.49
1.00
1.47
1.47
2.33
1.14
1.67
1.67
3.19
1.08
1.59
1.59
3.04
1.02
1.50
1.50
2.86
1.03
1.52
1.52
3.45
1.39
2.04
2.32
2.32
1.31
1.93
2.19
2.19
1.25
1.83
2.08
2.08
1.18
1.74
1.97
1.97
1.11
1.63
1.85
1.85
1.04
1.53
1.73
1.73
1.22
1.80
2.04
2.86
1.17
1.71
1.95
2.73
1.11
1.63
1.85
2.59
1.05
1.53
1.74
2.44
1.12
1.64
1.86
3.13
1.07
1.56
1.78
2.98
1.01
1.47
1.68
2.82
1.02
1.49
1.69
3.39
1.15
1.68
2.68
2.68
1.10
1.61
2.56
2.56
1.05
1.53
2.44
2.44
1.05
1.54
2.46
2.95
1.01
1.47
2.35
2.82
1.01
1.48
2.83
2.83
1.37
2.29
2.29
2.29
1.29
2.14
2.14
2.14
1.22
2.04
2.04
2.04
1.16
1.94
1.94
1.94
1.09
1.82
1.82
1.82
1.02
1.70
1.70
1.70
1.20
2.00
2.00
2.80
1.15
1.91
1.91
2.68
1.09
1.82
1.82
2.55
1.03
1.71
1.71
2.40
1.10
1.83
1.83
3.07
1.05
1.74
1.74
2.93
1.00
1.67
1.67
3.33
Unit F
Total
power consumption(kW)
12.00
3.57
( 3.50
- 13.50 ) (
12.00
4.03
( 3.50
- 13.50 ) (
12.00
4.53
( 3.50
- 13.50 ) (
12.00
5.01
( 3.50
- 13.50 ) (
12.00
2.92
( 3.50
- 13.50 ) (
12.00
3.34
( 3.50
- 13.50 ) (
12.00
3.77
( 3.50
- 13.50 ) (
12.00
4.26
( 3.50
- 13.50 ) (
12.00
4.73
( 3.50
- 13.50 ) (
12.00
3.19
( 3.50
- 13.50 ) (
12.00
3.61
( 3.50
- 13.50 ) (
12.00
4.09
( 3.50
- 13.50 ) (
12.00
3.45
( 3.50
- 13.50 ) (
11.80
2.32
( 3.40
- 13.20 ) (
12.00
3.07
( 3.50
- 13.50 ) (
12.00
3.50
( 3.50
- 13.50 ) (
12.00
3.95
( 3.50
- 13.50 ) (
12.00
4.44
( 3.50
- 13.50 ) (
12.00
4.92
( 3.50
- 13.50 ) (
12.00
2.86
( 3.50
- 13.50 ) (
12.00
3.27
( 3.50
- 13.50 ) (
12.00
3.70
( 3.50
- 13.50 ) (
12.00
4.19
( 3.50
- 13.50 ) (
12.00
3.13
( 3.50
- 13.50 ) (
12.00
3.55
( 3.50
- 13.50 ) (
12.00
4.02
( 3.50
- 13.50 ) (
12.00
3.39
( 3.50
- 13.50 ) (
12.00
2.68
( 3.50
- 13.50 ) (
12.00
3.07
( 3.50
- 13.50 ) (
12.00
3.49
( 3.50
- 13.50 ) (
12.00
2.95
( 3.50
- 13.50 ) (
12.00
3.35
( 3.50
- 13.50 ) (
12.00
2.83
( 3.50
- 13.50 ) (
11.90
2.29
( 3.50
- 13.40 ) (
12.00
3.00
( 3.50
- 13.50 ) (
12.00
3.43
( 3.50
- 13.50 ) (
12.00
3.87
( 3.50
- 13.50 ) (
12.00
4.36
( 3.50
- 13.50 ) (
12.00
4.84
( 3.50
- 13.50 ) (
12.00
2.80
( 3.50
- 13.50 ) (
12.00
3.21
( 3.50
- 13.50 ) (
12.00
3.64
( 3.50
- 13.50 ) (
12.00
4.11
( 3.50
- 13.50 ) (
12.00
3.07
( 3.50
- 13.50 ) (
12.00
3.49
( 3.50
- 13.50 ) (
12.00
3.33
( 3.50
- 13.50 ) (
137/266
Outdoor unit
Current
(A)
3.64
15.99
0.88
-
5.35
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
15.94
3.63
0.88
-
5.34
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
16.47
3.75
0.89
-
5.46
)
16.03
3.65
0.88
-
5.36
)
3.63
15.94
0.88
-
5.34
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.62
15.90
0.88
-
5.33
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
16.25
3.70
0.89
-
5.40
)
3.64
15.99
0.88
-
5.35
)
3.62
15.90
0.88
-
5.33
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
15.85
3.61
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
3.61
15.85
0.88
-
5.32
)
Power
factor(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99