OPERATING PROCEDURE
5. Removing the expansion valve
(1) Remove the top panel (Photo 1).
(2) Remove the service panel (Photo 1).
(Gas recovery is not required if the unit is pumped down.)
(3) Remove the front panel for removing LEV M (Photo 1).
(4) Remove the electrical parts for removing LEV M (Photo 3,
4).
(5) Remove the LEV coils.
(6) Detach the brazed parts of expansion valves and pipes.
Copyright 2010 MITSUBISHI ELECTRIC CORPORATION
Distributed in Mar. 2014. No.OBH584 REVISED EDITION-G
Distributed in Oct. 2013. No.OBH584 REVISED EDITION-F
Distributed in Jan. 2013. No.OBH584 REVISED EDITION-E
Distributed in Dec. 2012. No.OBH584 REVISED EDITION-D
Distributed in Jul. 2012. No.OBH584 REVISED EDITION-C
Distributed in Jun. 2012. No.OBH584 REVISED EDITION-B
Distributed in Apr. 2011. No.OBH584 REVISED EDITION-A
Distributed in Oct. 2010. No.OBH584
Made in Japan
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Photo 10
Suction pipe
brazed part
Discharge pipe
brazed part
Compressor nuts
Photo 11
New publication, effective Mar. 2014
Specifications are subject to change without notice.
130
PHOTOS
LEV coils
2 way valve solenoid coil
HPS
LEV coilf M
Expansion
valves
Expansion
valves