OPERATING PROCEDURE
5. Removing the outdoor fan motor
(1) Remove the top panel, cabinet and service panel
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor con-
necting wire.
(3) Disconnect the connectors for outdoor fan motor.
(4) Remove the propeller nut.
(5) Remove the propeller.
(6) Remove the screws fixing the fan motor (Photo 7).
(7) Remove the fan motor.
6. Removing the compressor and 4-way valve
(1) Remove the top panel, cabinet and service panel
(Refer to 1).
(2) Disconnect the power supply and indoor/outdoor con-
necting wire and remove the back panel (Refer to 1).
(3) Remove the inverter assembly (Refer to 2).
(4) Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
(5) Detach the brazed part of the suction and the dis-
charge pipe connected with compressor.
(6) Remove the nuts of compressor legs.
(7) Remove the compressor.
(8) Detach the brazed part of pipes connected with 4-way
valve.
OBH584G
(0 MPa).
2
Photo 6
Photo 7
Screws of the outdoor fan motor
Propeller
Photo 8
120
PHOTOS
Outdoor heat
exchanger
temperature
thermistor
Defrost
thermistor
Propeller nut
Brazed parts of 4-way valve

Hide quick links: