Controlling the Monitor with a PC (RS-232C)

You can control this monitor from a PC via RS-232C (COM
port) on the PC.

PC connection

Connect with RS-232 cross cable between the PC's COM port
(RS-232C connector) and the RS-232C input terminal on the
monitor.
RS-232 cross cable
RS-232C
(commercially available)
input terminal
To control the monitor via RS-232C, set STANDBY MODE
to STANDARD. Set OFF IF NO SIGNALE and OFF IF NO
OPERATION to DISABLE. When the monitor is in standby
mode with OFF IF NO SIGNAL and OFF IF NO OPERATION,
cannot switch to power on state. (See page 25.)

Communication conditions

Set the RS-232C communication settings on the PC to match
the monitor's communication settings as follows:
Baud rate
9600bps
Data length
8 bits
Parity bit
None

Communication procedure

nCommand format
When a command is sent from the PC to the monitor, the
monitor operates according to the received command and
sends a response message to the PC.
C1
C2
C3
C4
Command field
(4 prescribed
alphanumerical characters)
Example: VOLM030
* Be sure to input 4 characters for the parameter. Pad with
spaces (" ") if necessary.
("
" is a return code (0D
Wrong : VOLM30
Right
: VOLM030
PC
To COM port
Stop bit
1 bit
Flow control
None
Return code
P1
P2
P3
P4
Parameter field
(4 character string comprised of:
0-9, space, ?)
))
H
The current value can be returned by using "????" or "?
as the parameter.
Example:
VOLM ? ? ? ?
30
Wrong : VOLM
Right
: VOLM ?
nResponse code format
When a command has been executed correctly
O
K
Return code
(0D
A response is returned after a command is executed.
When a command has not been executed
E
R
R
TIPS
• "ERR" is returned when there is no relevant command or
when the command cannot be used in the current state of
the monitor.
• If communication has not been established for reasons
such as a bad connection between the PC and monitor,
nothing is returned (not even ERR).
• "ERR" may be returned when a command cannot be
received correctly due to interference from the surrounding
environment.
Please ensure that the system or software retries the
command if this occurs.
nCommunication interval
• After OK or ERR is returned, you must send the following
commands.
To set a timeout for the command response, specify 10
seconds or longer.
• Provide an interval of 100 ms or more between the
command response and the transmission of the next
command.
From PC to monitor (How much
is current volume setting?).
From monitor to PC (Current
volume setting: 30).
?
)
H
Return code
(0D
)
H
"
29
E