Selector
No.
1
Not used.
2
Ringer OFF setting
Automatic playback of OGM at
3
the start time of OGM ON mode
Detection of distinctive ringing
4
pattern
5
Automatic erasure of voice alarm
6
Recording quality level
7
Not used.
Motor overheating error indica-
8
tion
Selector 2:
Ringer OFF setting
This selector determines whether or not the ringer can be set to OFF.
Selector 3:
Automatic playback of OGM at the start time of OGM ON mode (For those models
equipped with a built-in TAD)
This selector determines whether or not the equipment automatically plays back an OGM the
moment it switches to the OGM ON mode in the MC mode.
Selector 4:
Detection of distinctive ringing pattern
If this selector is set to "0," the equipment detects only the number of rings; if it is set to "1,"
the equipment detects the number of rings and the ringing time length to compare the de-
tected ringing pattern with the registered distinctive one.
Selector 5:
Automatic erasure of voice alarm
This selector determines whether or not the voice alarm should be erased from the memory
after it is issued.
Selector 6:
Recording quality level (For those models equipped with a built-in TAD)
This selector determines the recording quality level (this function can be accessed also by
the user function 8-8). If it is set to "1" (High), the sampling rate by selector 7 of WSW27
takes effect; if it is set to "0" (Normal), the sampling rate specified by selector 4 of WSW30
takes effect.
Selector 8: Motor overheating error indication
If this selector is set to "0," the equipment displays the message "PRINTER FAULT" on the
LCD whenever a motor overheating error occurs so that any of the following happens and
the equipment aborts recording:
- The number of printed documents is five or less although the receiving operation contin-
ues for 15 minutes or more.
- The number of printed documents is 10 or less although the receiving operation continues
for 20 minutes or more.

WSW27

(Function setting 5)
Function
V – 38
Setting and Specifications
0: YES
1: NO
0: NO
1: YES
0: NO
1: YES
0: YES
1: NO
0: Normal
1: High
0: YES
1: NO