2. Remove the self-tapping screw, situated at the rear side of the machine, using the TX25 driver, as
shown in figure 11.
fig. 11
3. Remove, using the Allen key 4mm, the two M5 socket screws, situated at the bottom of the cover.
It's best practice to slide the machine to the edge of the table or counter where it's placed. See
figure 12.
4. Carefully remove the right hand cover from the
frame of the machine. Now, a flatcable,
connected to the Control PCB, will become
visible. Hold the cover with one hand, whilst
removing the flatcable connector from the
PCB. See arrow in figure 13.
5. The procedure for the left-hand cover is
similar, though it's obvious that there's no
flatcable on this side.
Assembly of the cover is in reverse order.
Note:
Make sure, that the flatcable has been placed back onto the PCB connector. Take
care, that the flatcable is not twisted.
Disassembly / Reassembly Procedures
fig. 12
fig. 13