Installation (duct is not supplied)
1. The range hood should be
mounted at a distance of
650mm from an electric or
induction cooktop and
700mm from a gas cooktop
for optimum performance. If
the instructions for
installation of the gas
cooktop specify a greater
distance, this has to be taken
into account (see pic 1). The exhaust
air must not be discharged into a
chimney which is used for exhausting fumes from
other appliances burning gas or other fuels
2. This item should be fitted by a competent person or
fitter who should only use the right screw fixing where
applies
3. To install, drill 2 holes of Ø8mm on a sturdy wall and in
line with the hood (see pic 2a). Or drill 4 holes of
Ø8mm on the lower side of the cupboard in line with
the hood(see pic 2b),detailed installation procedure
please see pic 4,5,6
4. Insert expanding screws into the hole if use the way as
pic 2a
5. Attach the duct to the one way valve, and connect it to
the kitchen outlet vent. (see pic 3)
6.
Do not connect to a common vent with other
appliance such as gas heater, water heater, laundry
dryer etc.