GENERAL INSTRUCTIONS

THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED
BY A QUALIFIED INSTALLER to conform with local codes.
Installation practices vary from region to region and it is
important to know the specifi cs that apply to your area,
for example: in Massachusetts State:
• The stove damper must be removed or welded in the open
position prior to installation of a stove insert or gas log.
A carbon monoxide detector is required in all rooms containing
gas fi red appliances.
• The appliance off valve must be a "T" handle gas cock.
• The fl exible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed
plumber or gas fi tter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current CAN1-B149
Installation Code in Canada or to the National Fuel Gas
Code, ANSI Z223.1, and NFPA 54 in the United States.
Mobile home installation must conform with local codes. In
the absence of local codes, install to the current standard for
gas equipped mobile housing CAN/CSA Z240 MH Series in
Canada or the manufactured home construction and safety
standard, Title 24 CFR, part 3280, or the Fire Safety Criteria
for manufactured home installations, Sites and Community
Standard ANSI/NFPA 501A in the United States.
Objects placed in front of the stove must be kept a
minimum of 48" away from the front face of the unit.
The stove and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of that system at test pressures in excess of ½ psig (3.5
kPa). The stove must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psig (3.5 kPa).
The stove, when installed with a blower, must be electrically
connected and grounded in accordance with local codes.
In the absence of local codes, use the current CSA C22.1
CANADIAN ELECTRICAL CODE in Canada or the ANSI/
NFPA 70 NATIONAL ELECTRICAL CODE in the United
States.
W415-0607 / A / 01.18.08
NorthlineExpress.com

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-
FIRED TO ASSURE ITS OPERATION AND QUALITY!
Minimum inlet gas supply pressure is 4.5 inches water column
for natural gas and 11 inches water column for propane.
Maximum inlet gas pressure is 7 inches water column for
natural gas and 13 inches water column for propane. When
the valve is set to "HI", the manifold pressure under fl ow
conditions is 3.5 inches water column for natural gas and 10
inches water column for propane. When the stove is installed
at elevations above 4,500ft, and in the absence of specifi c
recommendations from the local authority having jurisdiction,
the certifi ed high altitude input rating shall be reduced at the
rate of 4% for each additional 1,000ft.
Expansion / contraction noises during heating up and cooling
down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
with other gases, unless a certifi ed kit is used.
Maximum input is 25,000 BTU/hr for natural gas and propane.
Maximum output is 20,500 BTU/hr at an effi ciency of 82%.
Provide adequate accessibility clearance for servicing and
operating the stove.
Never obstruct the front opening of the stove.
Provided that the clearance to combustibles are achieved,
the most desirable and benefi cial location for a Napoleon®
stove is in the centre of a building, thereby allowing the most
effi cient use of the heat created. The location of windows,
doors and the traffi c fl ow in the room where the stove is to be
located should be considered. If possible, you should choose
a location where the vent will pass through the house without
cutting a fl oor or roof joist.
Rating Label Location: The rating label is located behind the
control door and is chained to the stove.

CARE OF GLASS AND PLATED PARTS

Do not use abrasive cleaners to clean these parts. Buff lightly
with a clean dry cloth.
3
The glass is
/
" ceramic glass available from your Napoleon®
16
/ Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS.
Clean the glass after the fi rst 10 hours of operation with a
recommended gas stove glass cleaner. Thereafter clean as
required. DO NOT CLEAN GLASS WHEN HOT! If the glass
is not kept clean permanent discolouration and / or blemishes
may result.