INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CSA 2.22 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
103 Miller Drive, Crittenden, Kentucky, USA, 41030
GDS25N
NATURAL GAS
GDS25P
PROPANE
WARNING
!
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.28D
EN
FR
PG
45
W415-0547 / J / 07.16.13

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GDS25N

  • Page 1 Decorative Product: Not for use as a heating appliance. NEVER ALLOW CHILDREN TO TOUCH GLASS. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS SPECIAL VENT INSTALLATIONS 3.2.1 PERISCOPE TERMINATION 3.2.2 CORNER TERMINATION VENT TERMINAL CLEARANCES DEFINITIONS ELBOW VENT LENGTH VALUES HORIZONTAL TERMINATION VERTICAL TERMINATION VERTICAL THROUGH EXISTING CHIMNEY INSTALLATION WALL AND CEILING PROTECTION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Cast, see “CAST FRONT INSTALLATION AND REMOVAL” section. On/Off, see “SWITCH FUNCTIONS” section. Door, see “GLASS DOOR INSTALLATION AND REMOVAL” section. Rating plate, see “RATING Blower, see PLATE INFORMATION” “OPTIONAL BLOWER section. INSTALLATION” section. W415-0547 / J / 07.16.13...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS Ø 4" 102mm Ø 7" 17 1/2" 178mm 445mm 23 5/8" 25 5/8" 600mm 651mm 12 3/4" 324mm 23 1/2" 597mm GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 6: General Information

    The installation must conform with local codes or, in absence of local codes, the National Gas and Propane We suggest that our gas Installation Code CSA B149.1 in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United hearth products be installed States.
  • Page 7: Rating Plate Information

    SONT3 PIEDS ET 40 PIEDS COTES DE L'EVENT 1" WOLF STEEL LTD. RESPECTIVEMENT. 24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA 4M 0G8 CAN GDS/CDVS25 SERIAL NUMBER / NO. DESERIE W385-0330 / E INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting and gas type of the unit.
  • Page 8: Venting

    3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT (0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 9 For optimum fl ame appearance and appliance operation, keep the vent length and number of elbows to a minimum. It is recommended that all horizontal runs have a minimum 1/4” (6.4mm) rise per foot /meter. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.
  • Page 10: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.2.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a 12” minimum of 12” (304.8mm) above grade. The maximum allowable vent length (304.8mm) is 10’...
  • Page 11: Vent Terminal Clearances

    VENT TERMINAL CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL (4.6m) (0.9m) INSTALLATIONS CANADA U.S.A. 12” (305mm) 12” (305mm) Clearance above grade, veranda porch, deck or balcony. 9” 12” (305mm) Clearance to windows or doors that open. Δ...
  • Page 12: Definitions

    DEFINITIONS For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 135°*) in feet - combined vertical vent lengths in feet...
  • Page 13: Horizontal Termination

    HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 45° and 90° rise V for the required horizontal run H elbow) 40 (12.2) 39 (11.9) 30 (9.1) REQUIRED VERTICAL 20 (6.1) RISE IN FEET (METERS) V 10 (3.1)
  • Page 14 ) > (V See graph to determine the required vertical Simple venting confi guration (only one 45° and 90° rise V for the required horizontal run H elbow) 150 (3810) 147 (3733.8) REQUIRED VERTICAL RISE 100 (2540) IN INCHES (MILLIMETERS) V 57 (1447.8) 50 (1270) (1.5)
  • Page 15: Vertical Termination

    VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL 20 (6.1) RISE IN FEET (METERS) V 10 (3.1) 3 (0.9) (1.5) (3.1) (6.1)
  • Page 16 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL RISE IN FEET 10 (3.1) (METERS) V 3 (0.9) (7.6) (9.1) (1.5) (3.1) (4.6) (6.1) HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS)H...
  • Page 17: Vertical Through Existing Chimney

    VERTICAL THROUGH EXISTING CHIMNEY WARNING RISK OF FIRE! CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON- COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD RESULT IN A FIRE. This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum fl ex vent system running the full length of a masonry chimney.
  • Page 18: Installation

    4.0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY. IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE “OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.
  • Page 19: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal location, cut and frame a hole in the exterior wall as VENT...
  • Page 20: Horizontal Air Terminal Installation

    HORIZONTAL AIR TERMINAL INSTALLATION WARNING TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS.
  • Page 21: Vertical Air Terminal Installation

    VERTICAL AIR TERMINAL INSTALLATION Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. Stretch the inner fl...
  • Page 22: Appliance Vent Connection

    APPLIANCE VENT CONNECTION Attach the adjustable pipe to the last section of rigid pipe. Secure #8 X 1/2” with screws and seal. SELF DRILLING Install the inner fl ex pipe to the appliance. Secure with 3 screws SCREWS and fl at washers. Seal the joint and screw holes using the high temperature sealant W573-0007 (not supplied).
  • Page 23: Mobile Home

    MOBILE HOME This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. Built in appliances are equipped with 1/4” diameter holes located in the front left and right corners of the base. Use #10 hex head screws, inserted through the holes in the base to secure. For free standing products contact your local authorized dealer / distributor for the appropriate securing kit.
  • Page 24: Minimum Clearance To Combustibles

    As long as clearance to combustibles is kept within the required distances, the most desirable and benefi cial location for a Napoleon® appliance is in the centre of a building, thereby allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the room where the appliance is to be located should be considered.
  • Page 25: Minimum Mantel Or Shelf Clearances

    MINIMUM MANTEL OR SHELF CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, HEARTH, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 26: Finishing

    5.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS REMOVED, CRACKED, BROKEN OR SCRATCHED. 72.4 CAST FRONT INSTALLATION AND REMOVAL WARNING GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. Lift the top cast piece off of the appliance.
  • Page 27: Glass Door Installation And Removal

    GLASS DOOR INSTALLATION AND REMOVAL WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. Lift the top cast piece off of the appliance. Pull handle and rotate 90°. Slide the door straight up to remove. LATCHES DOOR Follow the above steps in reverse in order to reinstall the door.
  • Page 28: Log Placement

    LOG PLACEMENT WARNING LOGS MUST BE PLACED IN THE EXACT LOCATION IN APPLIANCE. DO NOT CHANGE FROM THE PROPER LOG POSITIONS. APPLIANCE MAY NOT FUNCTION PROPERLY. THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. It is not necessary to remove the cast front, however, this will make for a more simple log installation. In order to assemble the log set, the glass door must be removed, see “CAST FRONT / GLASS DOOR INSTALLATION AND REMOVAL”...
  • Page 29: Switch Functions

    SWITCH FUNCTIONS MAIN ACCENT BURNER LIGHT SWITCH SWITCH CONTROL LOGO PLACEMENT Remove the backing from the logo and position onto the control door as shown. 1/2” LOGO 1/2” W415-0547 / J / 07.16.13...
  • Page 30: Optional Blower Installation

    6.0 OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 31: Wiring Diagram

    7.0 WIRING DIAGRAM WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT WITH THE GLASS DOOR OPEN OR REMOVED. The on/off switch is located on the back of the GDS25 at the top right corner. For ease of accessibility, an optional remote wall switch may be installed in a convenient location.
  • Page 32: Operation

    8.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 33: Adjustment

    9.0 ADJUSTMENT RESTRICTING VERTICAL VENTS Vertical installations may display a very active fl ame. Loosen the two screws and slide the restrictor plate blocking the exhaust path. This reduces the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more traditional fl...
  • Page 34: Maintenance

    10.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. DO NOT PAINT THE PILOT ASSEMBLY. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 35: Night Light Replacement

    • Access the blower, if equipped and clean using a soft brush and vacuum. • Re-assemble the various components in reverse order. • Inspect the relief system. The appliance relief through the main glass door or through the fl aps on the fi...
  • Page 36: Care Of Glass

    10.4 CARE OF GLASS WARNING DO NOT CLEAN GLASS WHEN HOT! DO NOT USE ABRASIVE CLEANERS TO CLEAN GLASS. HOT GLASS WILL Buff lightly with a clean dry soft cloth. Clean both sides CAUSE BURNS. of the glass after the fi rst 10 hours of operation with a DO NOT TOUCH GLASS recommended fi...
  • Page 37: Replacement Parts

    PILOT INJECTOR - LP W455-0071 PILOT INJECTOR - NG W720-0092 PILOT TUBE W100-0069 PILOT ASSEMBLY - NG W100-0093 PILOT ASSEMBLY - LP W385-0334 NAPOLEON LOGO W660-0009 ON/OFF SWITCH W387-0006 HALOGEN BULB 10W T320 W290-0108 TOP LENS GASKET W290-0109 BOTTOM LENS GASKET N402-0001...
  • Page 38 TERMINAL KITS PART NO. DESCRIPTION GD-175 WALL TERMINAL KIT BM6790 90° ELBOW - 7” (177.8mm) DIAMETER GD-222 TERMINAL ASSEMBLY BM67ADJ 30” (762mm) TO 53” (1346.2mm) ADJUSTABLE PIPE - 7” (177.8mm) DIA W010-1313 FIRESTOP SPACER W585-0267 TOP VENT SHIELD W020-0032 HARDWARE BM3730 BLACK TRIM COLLAR BM6724...
  • Page 39 ROOF TERMINAL KITS PART NO. DESCRIPTION GD-110 - 1/12 TO 7/12 PITCH W670-0006 AIR TERMINAL W490-0073 4/7 INNER / OUTER SLEEVE W010-0567 ROOF SUPPORT W170-0063 STORM COLLAR W263-0054 ROOF FLASHING GD-111 - 8/12 TO 12/12 PITCH W670-0006 AIR TERMINAL W490-0073 4/7 INNER / OUTER SLEEVE W010-0567 ROOF SUPPORT...
  • Page 40 W415-0547 / J / 07.16.13...
  • Page 41: Troubleshooting

    12.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 42 SYMPTOM PROBLEM TEST SOLUTION Continues to Short or loose Verify all connections. Verify the connections from the pilot spark and pilot connection in sensor assembly are tight; also verify these connections are not lights, but main rod. grounding out to any metal. burner will not Verify the TH wires are connected to the valve.
  • Page 43: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 44 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gourmet Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...
  • Page 45 APPOSEZ L’ÉTIQUETTE DU NUMÉRO DE SÉRIE DU CARTON ENFANTS TOUCHER LA VITRE. N° de série N° DE MODÈLE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonfoyers.com • ask@napoleon.on.ca 10,00$ 1.28C...
  • Page 46 TABLE DES MATIÈRES VUE D’ENSEMBLE DE L’INSTALLATION INTRODUCTION DIMENSIONS INSTRUCTIONS GÉNÉRALES INFORMATIONS GÉNÉRALES INFORMATION SUR LA PLAQUE D’HOMOLOGATION ÉVACUATION LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS INSTALLATIONS PARTICULIÈRES D’ÉVENTS 3.2.1 ENSEMBLE PÉRISCOPIQUE 3.2.2 TERMINAISON EN COIN EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON LÉGENDE VALEURS DU COUDE EN LONGUEURS D’ÉVENT TERMINAISON HORIZONTALE...
  • Page 47: Vue D'ensemble De L'installation

    1.0 VUE D’ENSEMBLE DE L’INSTALLATION Fonte, voir la section « INSTALLATION ET ENLÈVEMENT DE LA FAÇADE EN FONTE ». Marche/Arrêt, voir la section « FONCTIONS DES INTERRUPTEURS ». Porte, voir la section « INSTALLATION ET ENLÈVEMENT DE LA PORTE VITRÉE ». Soufflerie, voir la section «...
  • Page 48: Introduction

    2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET EST INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 49: Dimensions

    DIMENSIONS Ø 4" 102mm Ø 7" 17 1/2" 178mm 445mm 23 5/8" 25 5/8" 651mm 600mm 12 3/4" 324mm 23 1/2" 597mm INSTRUCTIONS GÉNÉRALES AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. PRÉVOYEZ UN ACCÈS SUFFISANT POUR ENTRETENIR ET OPÉRER L’APPAREIL.
  • Page 50: Informations Générales

    les maisons mobiles équipées au gaz CAN/CSA Z240 SÉRIE MM au Canada ou selon les normes ANSI Z223.1 et NFPA 54 aux États-Unis. Tant que les distances requises pour les dégagements aux matériaux combustibles sont respectées, le meilleur endroit pour un appareil est le Nous suggérons que nos centre de la maison, car ceci permet une meilleure utilisation de la chaleur appareils au gaz soient installés...
  • Page 51: Information Sur La Plaque D'homologation

    SONT3 PIEDS ET 40 PIEDS COTES DE L'EVENT 1" WOLF STEEL LTD. RESPECTIVEMENT. 24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA RRIE. ONTARIO L4 GDS/CDVS25 SERIAL NUMBER / NO. DESERIE W385-0330 / E INSTALLATEUR : Il est de votre responsabilité de cocher, sur la plaque d’homologation, les cases correspondant au modèle, au type d’évacuation et au type de gaz de l’appareil.
  • Page 52: Évacuation

    3.0 ÉVACUATION AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’ÉVENT ET À L’APPAREIL. SI LE SYSTÈME D’ÉVENT EST FOURNI AVEC DES ESPACEURS, LES COURSES HORIZONTALES ET VERTICALES DU SYSTÈME DOIVENT ÊTRE SUPPORTÉES À TOUS LES 3 PI (0,9m). UTILISEZ DES SUPPORTS OU DES ATTACHES INCOMBUSTIBLES ÉQUIVALENTS AFIN DE MAINTENIR LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES.
  • Page 53 Pour une performance optimale de l’appareil et une apparence optimale des fl ammes, gardez la longueur des évents et le nombre de coudes au minimum. Toutes les courses horizontales devraient avoir une élévation minimale de 1/4” (6,4mm) par pied/mètre. La prise d’air de la terminaison extérieure doit demeurer dégagée en tout temps. Vérifi ez la prise d’air de la terminaison au moins une fois l’an pour vous assurer qu’elle n’est pas obstruée ni endommagée.
  • Page 54: Installations Particulières D'évents

    INSTALLATIONS PARTICULIÈRES D’ÉVENTS 3.2.1 ENSEMBLE PÉRISCOPIQUE Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un 12” (304,8mm) minimum de 12 pouces (304,8mm) au-dessus du MINIMUM AU NIVEAU...
  • Page 55: Emplacements Et Dégagements Minimaux De La Terminaison

    EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON ††* APPLICATIONS POUR BALCON COUVERT INSTALLATION = 3 pieds = 2 x RÉELLE (0,9m) (4,6m) CANADA É.-U. 12” 12” Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon. (304,8mm) (304,8mm) 12”...
  • Page 56: Légende

    LÉGENDE Les symboles suivants sont utilisés dans le calcul et les exemples d’évacuation : > - plus grand que > - plus grand ou égal à < - plus petit que < - plus petit ou égal à - total de la longueur des courses horizontales (H ) plus la valeur des déviations (H ) en pieds - longueur des courses horizontales combinées en pieds...
  • Page 57: Terminaison Horizontale

    TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple (un coude de 45º et Consultez le graphique pour déterminer la course verticale de 90° seulement) nécessaire V par rapport à la course horizontale requise H 39 (11,9) 30 (9,1) COURSE VERTICALE REQUISE EN 20 (6,1) PIEDS...
  • Page 58 ) > (V Consultez le graphique pour déterminer la Confi guration d’évacuation simple (un coude de 45º et course verticale nécessaire V par rapport à la de 90°seulement) course horizontale requise H 150 (3810) 147 (3733.8) COURSE VERTICALE 100 (2540) REQUISE EN POUNCES (MILLIMETERS) V...
  • Page 59: Terminaison Verticale

    TERMINAISON VERTICALE ) < (V Configurations d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE REQUISE EN PIEDS 20 (6,1) (MÈTRES)V 10 (3,1) 3 (0,9) (1,5) (3,1)
  • Page 60 ) > (V Configurations d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6) (6,1)
  • Page 61: Terminaison Verticale À Travers Une Cheminée Existante

    TERMINAISON VERTICALE À TRAVERS UNE CHEMINÉE EXISTANTE AVERTISSEMENT RISQUE D'INCENDIE! LES CONFIGURATIONS D'ÉVACUATION COAXIALES À COLINÉAIRES NE DOIVENT ÊTRE UTILISÉES QUE DANS UNE CHEMINÉE OU UNE ENCEINTE DE NATURE INCOMBUSTIBLE. UNE INSTALLATION DANS UNE ENCEINTE COMBUSTIBLE PEUT CAUSER UN INCENDIE. Cet appareil est conçu pour être raccordé...
  • Page 62: Installation

    4.0 INSTALLATION AVERTISSEMENT AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE, ASSUREZ-VOUS DE RETIRER TOUTE COMPOSANTE NON FIXÉE À L’INTÉRIEUR DE LA CHAMBRE DE COMBUSTION. SI VOTRE APPAREIL COMPREND UN SYSTÈME DE TÉLÉCOMMANDE, ASSUREZ-VOUS QUE LE RÉCEPTEUR EST À LA POSITION « OFF » AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE.
  • Page 63: Installation Horizontale

    4.1.1 INSTALLATION HORIZONTALE AVERTISSEMENT L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. LA TERMINAISON NE DOIT PAS ÊTRE ENCHÂSSÉE DANS LE MUR OU LE REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. Cette confi...
  • Page 64: Installation Verticale

    4.1.2 INSTALLATION VERTICALE Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « Accessoires » pour commander l’ensemble spécifi que dont vous avez besoin. 9”...
  • Page 65: Installation De La Terminaison Horizontale

    INSTALLATION DE LA TERMINAISON HORIZONTALE AVERTISSEMENT LES TERMINAISONS NE DOIVENT PAS ÊTRE ENCHÂSSÉES DANS UN MUR OU UN REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. NE LAISSEZ PAS LA GAINE FLEXIBLE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES.
  • Page 66: Installation De La Terminaison Verticale

    INSTALLATION DE LA TERMINAISON VERTICALE AVERTISSEMENT CONSERVEZ UN ESPACE MINIMAL DE 2" (50,8mm) ENTRE LA BASE DE LA PRISE D’AIR ET LE COLLET DE SOLIN. Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit est optionnel. Dans ce cas, l’évent doit être supporté adéquatement soit en utilisant une méthode alternative se conformant aux normes des autorités compétentes, soit en utilisant le support de toit optionnel.
  • Page 67: Raccordement Des Évents À L'appareil

    RACCORDEMENT DES ÉVENTS À L’APPAREIL Attachez le tuyau télescopique à la dernière section de conduit rigide. Fixez-le avec des vis et scellez. AUTOPERCEUSES Raccordez la gaine fl exible intérieure à l’appareil. Fixez-la à #8 X 1/2” l’aide de trois vis et de trois rondelles. Scellez le joint et les têtes de vis avec du scellant à...
  • Page 68: Branchement Du Gaz

    BRANCHEMENT DU GAZ AVERTISSEMENT RISQUE D’INCENDIE, D’EXPLOSION OU D’ASPHYXIE. ASSUREZ-VOUS QU’IL N’Y A AUCUNE SOURCE D’ALLUMAGE, TELLES UNE ÉTINCELLE OU UNE FLAMME NUE. SOUTENEZ LE CONTRÔLE DU GAZ LORSQUE VOUS ATTACHEZ LE TUYAU D’ALIMENTATION EN GAZ POUR ÉVITER D’ENDOMMAGER LA CONDUITE DE GAZ. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 69: Dégagements Minimaux Aux Matériaux Combustibles

    DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES AVERTISSEMENT AFIN D’ÉVITER UN RISQUE D’INCENDIE, LES DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES DOIVENT ÊTRE MAINTENUS. SI L’OSSATURE OU LES MATÉRIAUX DE FINITION SE TROUVENT À UNE DISTANCE INFÉRIEURE À CELLE INDIQUÉE, ILS DOIVENT ÊTRE FAITS ENTIÈREMENT DE MATÉRIAUX NON COMBUSTIBLES (C.-À-D.
  • Page 70: Dégagements Minimaux De La Tablette

    DÉGAGEMENTS MINIMAUX DE LA TABLETTE AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ TOUS LES DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES SPÉCIFIÉS. NE PAS RESPECTER CES INSTRUCTIONS PEUT CAUSER UN INCENDIE OU UNE SUR- CHAUFFE. ASSUREZ-VOUS QUE TOUS LES DÉGAGEMENTS (C.-À-D. ARRIÈRE, CÔTÉS, DESSUS, ÉVENTS, TABLETTE, FAÇADE, ETC.) SONT RESPECTÉS À LA LETTRE. Lorsque l’évacuation de l’appareil se fait par l’arrière, une tablette peut être installée au-dessus du GDS25 à...
  • Page 71: Finitions

    5.0 FINITIONS AVERTISSEMENT RISQUE D’INCENDIE! N’OBSTRUEZ JAMAIS L'OUVERTURE SUR LE DEVANT DE L’APPAREIL. NE FRAPPEZ PAS, NE CLAQUEZ PAS ET N’ÉGRATIGNEZ PAS LA PORTE VITRÉE. NE FAITES PAS FONCTIONNER L’APPAREIL LORSQUE LA PORTE VITRÉE EST ENLEVÉE, FISSURÉE, BRISÉE OU ÉGRATIGNÉE. 72.4 INSTALLATION ET ENLÈVEMENT DE LA FAÇADE EN FONTE AVERTISSEMENT...
  • Page 72: Installation Et Enlèvement De La Porte Vitrée

    INSTALLATION ET ENLÈVEMENT DE LA PORTE VITRÉE AVERTISSEMENT N’UTILISEZ PAS DE MATÉRIAUX SUBSTITUTS. LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. Soulevez et retirez le dessus de l’appareil. Tirez la poignée et faites-la pivoter de 90°. Retirez la porte en la glissant vers le haut.
  • Page 73: Disposition Des Bûches

    DISPOSITION DES BÛCHES AVERTISSEMENT LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES, CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT. LES BÛCHES SONT FRAGILES ET DEVRAIENT ÊTRE MANIPULÉES AVEC SOIN. Il n’est pas nécessaire de retirer la façade en fonte, cependant cela facilitera l’installation des bûches. Pour installer les bûches, la porte vitrée doit être enlevée.
  • Page 74: Fonctions Des Interrupteurs

    FONCTIONS DES INTERRUPTEURS INTERRUPTEUR INTERRUPTEUR DE BRÛLEUR DE LA LUMIÈRE COMMANDE DE DE VEILLE LA SOUFFLERIE MISE EN PLACE DU LOGO Retirez le papier dorsal et positionnez le logo sur la porte de commande tel qu’illustré. 1/2” LOGO 1/2” W415-0547 / G / 08.01.13...
  • Page 75: Installation De La Soufflerie Optionnelle

    6.0 INSTALLATION DE LA SOUFFLERIE OPTIONNELLE AVERTISSEMENT RISQUE D’INCENDIE ET DE CHOC ÉLECTRIQUE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. N’UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES PIÈCES DE RECHANGE APPROUVÉS PAR WOLF STEEL POUR CET APPAREIL. L’UTILISATION D’ACCESSOIRES NON LISTÉS (SOUFFLERIE, PORTES, PERSIENNES, MOULURES, COMPOSANTS DE GAZ, COMPOSANTS D’ÉVACUATION, ETC.) POURRAIT ÊTRE NON SÉCURITAIRE ET ANNULERA LA GARANTIE ET LA CERTIFICATION.
  • Page 76: Schéma De Câblage

    7.0 SCHÉMA DE CÂBLAGE AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. L’interrupteur marche/arrêt est situé à l’arrière du GDS25, dans le coin supérieur droit. Pour faciliter l’accès, un interrupteur mural un optionnel peut être installé...
  • Page 77: Fonctionnement

    8.0 FONCTIONNEMENT AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 78: Réglages

    9.0 RÉGLAGES ÉTRANGLEMENT DES ÉVENTS VERTICAUX Vertical installations may display a very active fl ame. Loosen the two screws and slide the restrictor plate blocking the exhaust path. This reduces the velocity of the exhaust gases, slowing down the fl ame pattern and creating a more traditional fl...
  • Page 79: Entretien

    10.0 ENTRETIEN AVERTISSEMENT COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. L’APPAREIL PEUT ÊTRE CHAUD. ATTENDEZ QU’IL SOIT REFROIDI AVANT D’EN FAIRE L’ENTRETIEN. N’UTILISEZ PAS DE PRODUITS ABRASIFS. NE PEINTURE PAS L’ASSEMBLAGE DU VEILLEUSE. ATTENTION : Lors de l’entretien des contrôles, assurez-vous d’identifi...
  • Page 80: Remplacement De La Lumière De Veille

    • Inspectez tous les joints d’étanchéité accessibles et remplacez-les au besoin. • Accédez à la souffl erie, s’il y a lieu, puis nettoyez à l’aide d’une brosse souple et d’un aspirateur. • Réinstallez tous les composants dans l’ordre inverse. • Inspectez le système de surpression.
  • Page 81: Remplacement De L'injecteur De Veilleuse Et De L'injecteur De Brûleur

    10.3 REMPLACEMENT DE L’INJECTEUR DE VEILLEUSE ET DE L’INJECTEUR DE BRÛLEUR AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. Ceci doit être effectué par un REPRÉSENTANT AUTORISÉ DE WOLF STEEL LTÉE ou par un INSTALLATEUR DE GAZ QUALIFIÉ...
  • Page 82: Rechange

    11.0 RECHANGE Contactez votre détaillant ou le fabricant pour les questions concernant les prix et la disponibilité des pièces de rechange. Normalement, toutes les pièces peuvent être commandées chez votre détaillant autorisé. POUR UN REMPLACEMENT DE PIÈCE SOUS GARANTIE, UNE PHOTOCOPIE DE LA FACTURE ORIGI- NALE SERA REQUISE AFIN DE POUVOIR HONORER LA DEMANDE.
  • Page 83 ENSEMBLES DE TERMINAISON RÉF. PIÈCE DESCRIPTION GD-175 ENSEMBLE DE TERMINAISON MURALE BM6790 COUDE DE 90° - 7” DE DIAMÈTRE (177,8mm) GD-222 TERMINAISON BM67ADJ TUYAU AJUSTABLE 30” (762mm) À 53” (1346,2mm) - 7” (177,8mm) DIA. W010-1313 ESPACEUR COUPE-FEU W585-0267 ÉCRAN PROTECTEUR W020-0032 QUINCAILLERIE BM3730...
  • Page 84 ENSEMBLES DE TERMINAISON POUR TOIT RÉF. PIÈCE DESCRIPTION GD-110 - PENTE DE 1/12 À 7/12 W670-0006 TERMINAISON W490-0073 MANCHON INTÉRIEUR/EXTÉRIEUR 4/7 W010-0567 SUPPORT DE TOIT W170-0063 COLLET DE SOLIN W263-0054 SOLIN DE TOIT GD-111 - PENTE DE 8/12 À 12/12 W670-0006 TERMINAISON W490-0073...
  • Page 85 W415-0547 / G / 08.01.13...
  • Page 86: Guide De Dépannage

    12.0 GUIDE DE DÉPANNAGE MAINTENANCE MAINTENANCE AVERTISSEMENT MAINTENANCE ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 87 SYMPTÔME PROBLÈME SOLUTIONS Continue de Court-circuit ou Vérifi ez toutes les connexions. Vérifi ez si les connexions produire des connexion desserrée de l’assemblage de la veilleuse sont serrées; vérifi ez aussi étincelles et la dans la tige de la si ces connexions ne causent pas de mise à la terre au veilleuse sonde.
  • Page 88 SYMPTÔME PROBLÈME SOLUTIONS La fl amme du Système d’évacuation Enlever l’obstruction. Dans les conditions vraiment froides, brûleur principal bloqué. l’accumulation de glace peut arriver sur terminaison et est bleue, devrait être enlevée lorsque nécessaire. Pour minimiser paresseuse et ceci d’arriver encore, il est recommandé que les longueurs transparente de conduit qui passent par les espaces non chauffés (les greniers, les garages, rampent des espaces) est emballé...
  • Page 89: Garantie

    13.0 GARANTIE Les produits Napoléon® sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits Napoléon® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 90: Historique D'entretien

    14.0 HISTORIQUE D’ENTRETIEN 43.1 W415-0547 / G / 08.01.13...
  • Page 91: Notes

    15.0 NOTES 44.1 W415-0547 / G / 08.01.13...
  • Page 92 Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...

This manual is also suitable for:

Gds25p