PZ_SW_B_C: PZ2
PZ2: adjustment value of zoom PR switch position 2
(1051<=PZ2+PBR<=1116)
PZ_SW_C_B: PZ3
PZ3: adjustment value of zoom PR switch position 3
(1006<=PZ3+PBR<=1116)
PZ_BR: PBR
PBR: adjustment value of zoom backrush pulse
(0<=PBR<=45)
PZ_SP: PSP
PSP: adjustment value of zoom sink pulse
(210<=PSP<=320)
AF_SW: ASW
ASW: adjustment value of focus PI switch position
(893<=ASW<=985)
AF_BR: ABR
ABR: adjustment value of focus backrush pulse
(0<=ABR<=12)
AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(–44<=ZW<=47)
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(–76<=ZM1<=48)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(–104<=ZM2<=57)
AF_MID3: ZM3
ZM3: adjustment value of focus at zoom position middle3
(–97<=ZM3<=76)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(–98<=ZT<=94)
2. AWB Adjustment
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Pattern box
(color viewer)
2
)
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera when zoom tele edge. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Dsc Calibration
AWB Results:
1:
WB=245,482,418
CHECK=128,129,138
MS=4263,4390
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLEVEL_FOR_ISO=-1
Adjustment value determination is effectuated using "WB",
"CHECK" and "MS" values.
If WB=w1, w2, w3, CHECK=wc0, wc1, wc2, MS=ms1, ms2
and the adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
200<=w1<=310, 310<=w3<=470
wc0=128 ± 2, wc1=128 ± 2, wc2=150 ± 50
3400<=ms1<=5300, 3450<=ms2<=5350
Adjustment values other than the above are irrelevant.
3. White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select "CCD Defect" on the LCD "Test", and click the "Yes".
3. After the adjustment is completed, OK will display.
4. Click the OK.
– 17 –