For the Step Top Pedestal Model In US installations, it is
necessary to install a fl oor protector of a minimum of 3/8 inch
(9.5mm) thick metal clad millboard or equivalent a minimum
of 16 inches (406mm) in front of glass and 8 inches (203mm)
to both sides of the fuel loading door. Open the door and
measure 8 inches (203mm) from the side edge of the open-
ing in the face of the appliance. *See page 12 for Canadian
clearances and horizontal venting exception.
Fuel loading door
16 in. from glass
31-5/8 in.
minimum
Figure 13.1
203mm (8 in.)
203mm
(8 in.)
457mm (18 in.)
1041mm (41 in.)
minimum
Figure 13.2
NOTE:
August 3, 2015
Step-Top Uni-Body Model
.
39 in.
minimum
8 in.
USA
Must extend 2 in.
(51mm) beyond
each side of pipe
(shaded area)
203mm
(8 in.)
1254mm
(49-3/8 in.)
minimum
CANADA
Illustrations and photos refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design preference
Hearth & Home Technologies reserves the right to alter its products.
For the Step Top Leg Model In US installations, it is nec-
essary to install a fl oor protector of a minimum thickness of
1-1/4 inch (32mm) or 1/2 inch of "k" value of 0.84 or R value
= 0.59 thick metal clad millboard or equivalent a minimum of
16 inches (406mm) in front of glass and 8 inches (203mm)
to both sides of the fuel loading door. Open the door and
measure 8 inches (203mm) from the side edge of the open-
ing in the face of the appliance. *See page 12 for Canadian
clearances and horizontal venting exception. See Page
24 for calculation for alternate fl oor protection.
Corner hearth pad dimensions
Figure 13.3
Corner hearth pad dimensions
with double wall pipe
Figure 13.4
NOTE: Corner hearth pad dimensions are based off of 18" min. clear-
ance for single wall pipe, 6" min. for double wall pipe, OR unit tested
safety clearances to combustibles whichever is greater.
7033-277N
3100 Wood Stove Series (ACC)
with single wall pipe
50 in.
48-1/2 in.
30-3/4 in
29 in.