User Manual V1.1
User Manual
-Installation
-Operation
Z10I1K
Z10I1K5
Z10I2K
Z10I2K5
Z10I3K
Zeus Appollo Solar

Advertisement

Table of Contents
loading

Summary of Contents for Zeus Appollo Z10I1K

  • Page 1 User Manual V1.1 User Manual -Installation -Operation Z10I1K Z10I1K5 Z10I2K Z10I2K5 Z10I3K Zeus Appollo Solar...
  • Page 3: Table Of Contents

    Contents Notes on this manual ................................. 2 Scope of Validation ..............................2 Symbols Used ................................2 Target Group ................................3 Preparation ..................................4 Safety Instructions ............................... 4 Explanations of Symbols on Inverter ........................... 6 Product Information ................................7 Overview ..................................7 Major Characteristics ..............................
  • Page 4: Notes On This Manual

    1.1 Scope of Validation The main purpose of this User Manual is to provide instructions and detailed procedures for installing, operating, maintaining, and troubleshooting the following five types of Z10 series inverters: • Z10I1K • Z10I1K5 • Z10I2K • Z10I2K5 •...
  • Page 5: Target Group

    NOTICE NOTICE indicates a situation that can result in property damage, if not avoided. 1.3 Target Group • Chapter1, 2, 3, 4, 7, 8, 9, 10 and chapter 11 are provided for anyone who is intending to use a Z10 Series Grid-tied Solar Inverter. Before any further action is taken, the operators must first read all safety regulations and be aware of the potential danger when operating high-voltage devices.
  • Page 6: Preparation

    Any unauthorized activities including the modification of product functionality of any kind will affect the extent of the warranty; such actions may result in Zeus Appollo Solar not accepting any responsibility for that warranty.
  • Page 7 NOTICE Public utility only The PV inverter is designed to feed AC power directly into the public utility power grid; do not connect the AC output of the device to any private AC equipment. CAUTION The PV inverter will become hot during operation; please do not touch the heat sink or adjacent surfaces during or shortly after operation.
  • Page 8: Explanations Of Symbols On Inverter

    Equipment with the CE mark fulfils the basic requirements of the Guideline Governing Low-Voltage and Electromagnetic Compatibility. No unauthorized perforations or modifications Any unauthorized perforations or modifications are strictly forbidden, if any defect or damage (device/person) occurs, Zeus Appollo Solar will not be held responsible.
  • Page 9: Product Information

    Product Information 3.1 Overview • Industrial Layout Excellent Heat Elimination • Effective Shield For DC/AC/Communication Connections •...
  • Page 10: Major Characteristics

    3.2 Major Characteristics The Z10 series inverter has the following characteristics which ensures that it delivers on the promise of “high efficiency, high reliability, and having a high cost effective ratio” • An extensive DC input voltage and current range which enables more PV panels to be connected.
  • Page 11: Datasheet

    3.3 Datasheet Type Z10I1K Z10I1K5 Z10I2K Input (DC) Max. PV Power 1300W 1750W 2300W Max DC Voltage 500V 500V 500V Nominal DC Voltage 360V 360V 360V Operating MPPT Voltage 80-360V 120-450V 120-450V Range MPPT Voltage Range at 150-360V 150-450V 150-450V...
  • Page 12 Type Z10I1K Z10I1K5 Z10I2K Safety and Protection DC Insulation Monitoring DC Switch Optional Residual Current Integrated Monitoring Unit (RCMU) Grid Monitoring with Anti- islanding Protection Class I (According to IEC 62103) Overvoltage Category PV II / Mains III (According to IEC 62109-1)
  • Page 13 Type Z10I2K5 Z10I3K Input (DC) Max. PV Power 2800W 3250W Max DC Voltage 500V 500V Nominal DC Voltage 360V 360V Operating MPPT Voltage Range 120-450V 120-450V MPPT Voltage Range at Nominal 150-450V 150-450V Power Start up DC Voltage 150V 150V Turn off DC Voltage 120V 120V...
  • Page 14 Type Z10I2K5 Z10I3K Safety and Protection DC Insulation Monitoring DC Switch Optional Residual Current Monitoring Unit Integrated (RCMU) Grid Monitoring with Anti-islanding Protection Class I (According to IEC 62103) Overvoltage Category PV II / Mains III (According to IEC 62109-1) Reference Standard Safety Standard EN 62109, AS/NZS 3100...
  • Page 15: Packing Checklist

    Packing checklist 4.1 Assembly parts After you receive the Z10 series inverter, please check to see if there is any damage to the carton, and then examine the inverter and accessories for any visible external damage. Contact your dealer if anything is damaged or missing. Object Quantity Description...
  • Page 16: Product Appearance

    4.2 Product Appearance • Front Object Description Removable front shield LED light (3 pcs) Function keys for displays and setting(4 pcs) Monitoring LCD with backlighting • Bottom...
  • Page 17: Product Identification

    Object Description DC switch (optional) Plug connectors for DC input Terminal for grid connection (AC output) Communication interface(RS485/GPRS/Wi-Fi/USB) 4.3 Product Identification You can identify the inverter by the side name plate. Information such as the type of inverter, as well as the inverter specifications are contained on the side name plate. The name plate is located on the middle part of the right hand side of the inverter housing.
  • Page 18: Installation

    Installation 5.1 Safety DANGER DANGER to life due to potential fire or electricity shock. DO NOT install the inverter near any flammable or explosive items. This inverter will be directly connected with a HIGH VOLTAGE power generation device; the installation must be performed by qualified personnel only in compliance with national and local standards and regulations.
  • Page 19: Mounting Instructions

    5.2 Mounting Instructions • Z10 series inverter is designed for both indoor and outdoor installations. Zeus Appollo Solar recommends installing the inverter in a basement or garage where there is no direct exposure to sunlight or rain. • Do not install in rooms where people live or where the prolonged presence of people or animals is expected due to the level of noise that the inverter may make during operation.
  • Page 20: Safety Clearance

    5.3 Safety Clearance Observe the following minimum clearances to walls, other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle. Direction Minimum clearance Above 30 cm Below 40 cm Sides 10 cm...
  • Page 21: Mounting Procedure

    5.4 Mounting Procedure 1. Mark the four (4) positions of the drill holes on the wall corresponding with the wall mounting bracket in the carton. ( D epth 50mm )...
  • Page 22 2. Where the wall is marked, drill 4 holes and then insert the four expansion tubes into the holes using a rubber hammer. Next insert the 4 screws through the mounting holes in the bracket and then tighten the screws into the expansion tubes. The bracket is now installed.
  • Page 23 3. Check the 4 holes at the rear of the inverter and lift the inverter carefully, aligning the 4 holes in the inverter into the 4 hooks on the bracket. Once align, attach the inverter gently onto the bracket.
  • Page 24: Safety Lock

    5.5 Safety lock After the inverter is hanging up on the bracket, lock up the device and the bracket together at the Lower Left Corner of the inverter (as per the picture below). Padlock Recommended padlock dimension: A φ . S hackle Diameter 5~7 mm V ertical Clearance...
  • Page 25: Electrical Connection

    Electrical Connection 6.1 Safety DANGER DANGER to life due to potential fire or electricity shock. When the inverter is powered up, comply with all applicable national regulations legislation concerning accident prevention. This inverter will be directly connected to a HIGH VOLTAGE power generation device;...
  • Page 26 The Z10 series inverter is equipped with an integrated RCD (Residual Current Protective Device) and RCM (Residual Current Operated Monitor). The current sensor will detect the volume of the leakage current and compare it with the pre-set value, if the leakage current exceeds the permitted range, the RCD will disconnect the inverter from the AC load.
  • Page 27 1) Insert the stripped N, L and PE conductor terminals into the appropriate holes, using a cross screwdriver to tighten it, applying a tightening torque of 1Nm. 2) Insert the connector into the clamp ring, it should click twice and then tighten the hex nut with a tightening torque of 4Nm.
  • Page 28 3) Finally push the straight plug to the AC terminal on the inverter , t hen rotate the locker according to the direction instructed by the marks on the locker . 4) If you need to separate the connectors, please use a screwdriver to press the lock tongue, rotate the locker according to the direction instructed by the marks on the locker, and then pull down the plug.
  • Page 29: Dc Side Connection

    6.3 DC Side Connection DANGER DANGER to life due to potential fire or electricity shock. NEVER connect or disconnect the connectors under load. NOTICE The DC Switch ( Optional ) may be integrated or external to Inverter, and it can be used to connect or disconnect the DC source from the Inverter.
  • Page 30 For Z10I1K, Z10I1K5, Z10I2K, Z10I2K5 and Z10I3K, there is one MPP Tracker, and the DC characteristics of them are illustrated as the following table. Max. DC Max. DC Max. DC Inverter Type Tracker Power Voltage Current Z10I1K 1300W Z10I1K5 1750W...
  • Page 31: Tools Required

    PV-KBT4 PV-KST4 PV-SSH4 Touch 17A(1,5mm /16AWG) Rated protection, IP67/IP2X 22A(2,5mm /14AWG) current 30A(4mm ,6mm /10AWG) mated/unmated Ambient -40° to 90° C (IEC/CEI) Rated 1000V (IEC/CEI) temperature -40° to 75° C(UL) 600V (UL) voltage -40° ...70° C (UL:14AWG) range Upper limiting Safety class 105°...
  • Page 32 (ill. 7) Open-end spanner A/F 15 mm (ill. 8) Torque screwdriver A/F 12 mm Cable preparation (ill. 9) Use 14-10AWG (2.5-6mm ) conductor as DC cable. Dimension A3-6mm, b2.5-6mm (ill. 10) Strip the cable end L with 6 mm to 7.5 mm of insulation. (ill.
  • Page 33 (ill. 13) Insert the stripped cable end until the insulation comes up against the crimp insert. Completely close the crimping pliers. (ill. 14) Visually check the crimp. (ill. 15) Insert the crimped-on contact into the insulator of the male or female coupler until it clicks into place. Pull gently on the lead to check that the metal part is correctly engaged.
  • Page 34: Communication And Monitoring Device

    6.4 Communication and Monitoring Device There are 2 RJ45 ports on the bottom side of the Z10 series inverter as shown in the following figure: The 2x RJ45 ports are used for multipoint communications. Up to 50 Z10 series inverters can be connected via these 2 ports. The upper computer can communicate with these inverters via a single signal cable at the same time with support for a maximum cable length of 1000m.
  • Page 35 Object Description LED light(Yellow) – COM LED light(Green) – RUN LED light(Red) – FAULT UP key DOWN key ESC key ENTER key The LCD panel is integrated in the front lid of the inverter for easier user access to check, collate and set data. In addition, the user can press the function key to illuminate the LCD screen.
  • Page 36: Commissioning

    7.2 Commissioning NOTICE The power supply of the display module is accessed through the AC grid, so the screen will not be available until the AC is connected. A minimum available voltage of 150Vdc and a DC power of >10Wdc is required before the inverter starts feeding power to the grid.
  • Page 37 In this interface, the displayed “ Waiting 0 ” part will switch along with the system operation status. The system will have the following status: 1. Waiting status: Display as Waiting XXX, XXX refers to the countdown time, will display 1~3 numbers. 2.
  • Page 38 This interface displays the voltage and frequency of grid and the current which inverter outputs to the grid. System operation interface 5: This interface displays the Wi-Fi information of the inverter, including Wi-Fi SN and IP address. 7.3.2 Interface introduction Safety Interface: When choose “Safety”...
  • Page 39 After entering the password, system will get to the safety selection interface. Safety selection interface: The selected safety information flickers. The selectable safety information is as follows: Italy VDE-4105 VDE-0126 Spain GREMAIN Portugal Belgium Italy_S EnglG83 EnglG59 Austral China GerBDEW Danmark GreIsla Czech...
  • Page 40 Info Interface: You can choose “Info” by UP and DOWN key in system operation interface 1 While “Info” flickers. Confirm to enter Info mode. There will be 7 interfaces in the Info mode. PV panel information: AC grid information:...
  • Page 41 Inverter’s model information: Inverter’s SN information: Inverter’s master CPU information:...
  • Page 42 Inverter’s slave CPU information: Inverter’s display module version information: Error record display interface: You can choose “Error” by UP and DOWN key in system operation interface 1 While “Error” flickers, confirm to enter the Error record mode. Interface number of the Error record mode is unfixed; it ranges from 0 to 9 interfaces.
  • Page 43 No error record interface: Recent error record interface: Earliest error record interface:...
  • Page 44 Set mode: You can choose “Set” by UP and DOWN key in system operation interface 1 While “Set” flickers, confirm to enter the Set mode. The Set mode is operated with 2 levels of menu. There are five items in the sub-menu, Time, Data, Password, Language and Wi-Fi.
  • Page 45 While “Language” flickers, confirm to enter the language option list. Choose the target language, the corresponding language flickers. English, Dutch and German are available for displaying. Click ENTER to save data and back to prior menu. Changing Password: In the Set mode, choose “ Password ” by UP and DOWN key as shown in the picture. While “Password”...
  • Page 46 Save password after the end of input Back to two-level menu mode after saving the password Setting Time: In the Set mode, choose “Time” by UP and DOWN key as shown in the picture. While “Time” flickers, confirm to enter the inverter time setting mode. There are hour, minute and second displayed in the time setting mode.
  • Page 47 Setting Date: In the Set mode, choose “Date” by UP and DOWN key as shown in the picture. While “Date” field flickers, confirm to enter the inverter Date Setting mode There are day, month and year displayed in the date setting mode, set date by Up/Down key.
  • Page 48: State Information

    7.4 State Information State Display State information Waiting Initialization & waiting Wait Reconnects Reconnect Checking’s Checking Normal Normal Normal state Current Fault GFCI failure oversized leakage current Master Grid Freq Fault Grid frequency failure Master Grid Freq Fault Grid voltage failure PV Voltage Fault Input voltage too high Over Temp Fault...
  • Page 49: Troubleshooting

    2. Find a way to reduce the ambient temperature. 3. Or move the inverter to a cooler environment. 1. Check the open PV voltage; see if it is greater than or too close to 500VDC (for Z10I1K, Z10I1K5, Z10I2K, Z10I2K5 PV Voltage Fault or Z10I3K).
  • Page 50 Error code list : : : : ERROR CODE Description GFCI Device Fault Hole Sense Device Fault Reference Device Fault DCI ENS Fault GFCI ENS Fault Less Bus Low Voltage Fault Over Bus High Voltage Fault Master Device Fault Master Delta Grid Z Fault No Utility Current Fault Bus Voltage Fault...
  • Page 51: Abbreviation

    Abbreviation Liquid Crystal Display Light Emitting Diode MPPT Maximum Power Point Tracking Photovoltaic Voltage at the DC side Voltage at the AC side Vmpp Voltage at the Maximum Power Point Impp Amperage at Maximum Power Point Alternating Current ( Form of electricity supplied by Utility Company ) Direct Current ( Form of electricity generated by PV modules )
  • Page 52: Contact

    10. Contact Beijing Hua Xin Liu He Investment (Australia) Pty Ltd. Website: www.zeusappollo.com Perth Office 1/87 President Street Welshpool, WA 6106 Phone: (08) 6555 6518 Fax: (08) 9470 4103 Email: sales@zeusappollosolar.com.au Brisbane Office 32 Crockford Street Banyo, QLD 4014 Phone: (07) 3123 6148 Fax: (07) 3266 4758 Email: bris@zeusappollosolar.com.au...