Setting Pump Run-On Time - Buderus Logano plus GB402 Operating Instructions Manual

Gas condensing boiler
Table of Contents

Advertisement

3
Operation
3.5

Setting pump run-on time

The pump is automatically switched on
permanently in case of weather-
compensated control and temperatures
below 3 °C.
The standard setting for the pump run-on time is suitable
for most situations.
Exception for room temperature-dependent
control: If there is a risk of frost for the components of
the heating system that are located outside the range
of influence of the room temperature controller
(e.g. radiators in the garage), the pump run-on time must
be set to 24 hours (
Tab. 6).
Step
e e
(twice)
e e (twice)
or wait 5 minutes
Tab. 6 Pump run-on time
12
Settings menu
Display
[\/2/4|
Currently recorded flow temperature in °C (display in standard mode).
[\/f/5|
Pump run-on time in minutesHold down d for
Hold down c until the required pump run-on time is shown
[f//0|
(at least
[\/2/4|
Back to standard operation.
= 15 seconds)
Logano plus GB402 - Subject to technical modifications.
[f/d1|
(24 hours)