Download Print this page
Ness 5000 SERIES Installation Manual
Ness 5000 SERIES Installation Manual

Ness 5000 SERIES Installation Manual

Dialler
Hide thumbs Also See for 5000 SERIES:

Advertisement

NESS 5000 SERIES DIALLER
INSTALLATION MANUAL
This manual is designed to provide the installation instructions on the NESS SECURITY
PRODUCT'S 5000 SERIES Dialler. For complete details on the warranty or the 5000 SERIES
products. please refer to our conditions of sale.
NESS SECURITY PRODUCTS
4/167 Prospect Hwy.
Seven Hills. 2147
N.S.W. Australia
Head Office.
SYDNEY
BRISBANE
MELBOURNE Phone: (03) 9878 1022
PERTH
Copyright by NESS SECURITY PRODUCTS, July 1987.
DESIGN CONCEPTS
The 5000 SERIES Dialler is totally unique in that 2 separate
diallers share the one Circuit board and telephone line. It is not simply
one dialler with two Client Account Numbers, but 2 separate, individually
programmable diallers sharing the same hardware.
With this unique design and the many other features built into the
5000 SERIES Dialler, NESS has been able to provide you with a product
capable of meeting the diverse needs of virtually all installations. In
addition, it provides a simple means of overcoming, at no extra cost, the
8 alarm channel limitation of most Central Station equipment. Some of
the unique capabilities of this Dialler are explained below.
EXTRA TELEPHONE NUMBER: The Primary and Secondary telephone
numbers are basically designed for reporting to the Main and Back-up
receivers of a Central Station. An Extra telephone number, which may
be programmed by the client, has been provided for added flexibility. By
setting option 4 of P35E, the Extra number will be used in addition to
the Primary/Secondary numbers. If both options 0 and 4 of P35E are
set, then only the Extra telephone number it used for either or both
Diallers as required.
POCKET PAGER: To indicate an alarm via a 'beeper' type pocket pager,
the Dialler only has to call a number and wait for a special
Acknowledge tone. It does not have to send any alarm reports. This
facility is available via option 5 of P36E.
COMMAND TONE: An optional Tone Generator may be purchased to
remotely control certain aspects of the Dialler (if so programmed).
To use the facility, call the Dialler and when it answers, put the Tone
Generator near the mouthpiece and press its button. The Dialler will
respond with a series of beeps depending on the options selected.
5000 Series Dialler
Phone: (02) 8825 9222
Phone: (07) 3343 7744
Phone: (08) 9328 2511
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 5000 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Ness 5000 SERIES

  • Page 1 INSTALLATION MANUAL This manual is designed to provide the installation instructions on the NESS SECURITY PRODUCT'S 5000 SERIES Dialler. For complete details on the warranty or the 5000 SERIES products. please refer to our conditions of sale. NESS SECURITY PRODUCTS 4/167 Prospect Hwy.
  • Page 2 INSTALLATION The 5000 SERIES Dialler board is designed to plug into the 8 Zone Control Panel. It cannot be used in conjunction with the 4 Zone Control Panel. To install the Dialler, remove the Control Panel board from the housing, clip the Dialler into the third or fourth slot, connect the 13-way ribbon cable between the dialler and the control panel.
  • Page 3 5000 Series Dialler OUTPUTS Four plug-in screw terminals on the right-hand side of the Dialler provide the following outputs COMMON (-ve) LISTEN output AUXILIARY Output (of Dialler) 12 volt Output Connect any speaker between the LISTEN and COMMON terminals to listen in to the telephone line when the Dialler is making a call.
  • Page 4 5000 Series Dialler PROGRAMMING Programming the Dialler is virtually identical to programming the Control Panel - simply plug the Dialler in and use the Installation options on the following pages. However, for security reasons, the Dialler contains an optional Installer Access Code to protect the Central Station information.
  • Page 5 5000 Series Dialler SOFTWARE DATE, INSTALLER PROGRAM ACCESS CODE. P30E Code E Code E Pressing P30E will display the release date (month and year only) of the Software version currently installed in the Dialler. To program your secret Installer Access Code, enter it twice as shown above (ie.
  • Page 6 DIALLER #1 and #2 TRANSMISSION FORMAT. P36E option E If no acknowledge tone is received, transmit in the NESS Audible format. If transmitting in Low Speed format, old alarms which are still active are to be included in the transmission.
  • Page 7 5000 Series Dialler TYPE of DIALLING. P37E option E Use Decadic or Touch-Tone dialling depending on the type of dial-tone received. (First call only). Use Decadic dialling only. Use Touch-Tone dialling only. Use Touch-Tone dialling only and dial using Telecom Australia's EASY DIAL facility.
  • Page 8 5000 Series Dialler AUXILIARY OUTPUT DRIVE. P41E option E No Auxiliary drive Turn 0utput ON when a Line Fault is detected. Turn output ON when a Kiss-off tone is not received. Turn output ON when a Kiss-off tone is received.
  • Page 9 5000 Series Dialler RING-DETECT and TEST CALL OPTIONS. P 44 E option E Enable Auto-Test calls when Armed Enable Auto-Test calls when Disarmed Enable Call-Back calls when Armed. Enable Call-Back calla when Disarmed. Enable Auto-Answer capability when Armed. Enable Auto-Answer capability when Disarmed.
  • Page 10 5000 Series Dialler DOUBLE RINGS NEEDED FOR AUTO-ANSWER. P 48 E number E This option defines the number of double rings needed to make the Dialler Auto-Answer, ie. to answer an incoming call. The number may be set from 1 to 15.
  • Page 11 5000 Series Dialler The following three features may be used to modify, for each alarm, the basic transmission procedure to a Central Station. ABORT TIME: Delay dialling until after this time. If the Control Panel, or the input is reset during the Abort Time, the alarm is cancelled and no dialling takes place.
  • Page 12 5000 Series Dialler INSTALLATION PROGRAMMING OPTIONS SUMMARY Default value none P3OE code E code E = Installer Access Code P98E = Set all options to default P3lE telephone no.E = Primary telephone no. P32E telephone no.E = Secondary telephone no.
  • Page 13 INSTRUCTION MANUAL DIALLER OPERATION If you have a 5000 SERIES Dialler fitted to your 8 ZONE Control Panel, you are provided with many additional features as well as the capability to transmit alarms to a Central Monitoring station. This manual is designed to provide instructions on those Dialler features which may be under your control.
  • Page 14 5000 Series Dialler REMOTE CONTROL/STATUS REPORT An optional REMOTE CONTROL device may be purchased to either Arm the Control Panel via the Dialler or to operate the Dialler's AUXILIARY output from a remote location. These features can only be enabled by your installer.
  • Page 15 P 20 E 240 E NOTE: Do not forget to change the time to 0 when you go on holidays. AUTHORISATION TELECOM AUSTRALIA - INSTRUCT1ONS TO CUSTOMER Apparatus - Type : 5OOOD (5000 Series Dialler/Communicator) Authorisation No. C87/3/94 Page 15...