Astria Marin40STTMN Installation And Operation Instructions Manual

B-vent gas fireplaces

Advertisement

Quick Links

P/N 900301-01 Rev. NC 02/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900301-03.
P900301-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
Astria Marin
PFS
Models
Marin40STTMN
®
C
US
Report No. F14-172
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec
la vitre chaude et doit être installé pour la protection
Des enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
• Si vous ne pouvez rejoindre le fournisseur de
— L'installation et l'entretien doivent être assurés par
B-Vent Gas Fireplaces
TM
AVERTISSEMENT:
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
gaz depuis un voisin. Suivez les instructions du
fournisseur.
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Marin40STTMN and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Marin40STTMN

  • Page 1 Installation and Operation Instructions Astria Marin B-Vent Gas Fireplaces P/N 900301-01 Rev. NC 02/2015 Models Ce manuel est disponible en francais, simplement Marin40STTMN ® en faire la demande. Numéro de la pièce 900301-03. Report No. F14-172 P900301-01 INSTALLER: Leave this manual with the appliance.
  • Page 2 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: General Information

    Innovative Hearth Products General Information Astria™ Marin B-Vent Gas Fireplace 900301-01, 02/2015 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la IHP fireplace get...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS PACKAGING WARNING The assembled vented gas fireplace is pack- Packaging .........Page 4 Young children should be care- aged with: Introduction ........Page 4 fully supervised when they are General Information ......Page 4 1 - One log set located within the firebox. in the same room as the appli- Requirements for the 2 - One plastic bag containing the literature...
  • Page 5 WARNING WARNING Improper installation, adjust- Failure to position the parts in ment, alteration, service or accordance with these diagrams maintenance can cause injury or failure to use only parts or property damage. Refer to specifically approved with this this manual. For assistance or appliance may result in property additional information consult damage or personal injury.
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    Gas Pressure - All Models Orifice Sizes - Sea Level to High Altitude Gas Valve Diagrams (All Models) Tables 2 and 3 show the appliances' inlet and See Figure 1 for Millivolt models. manifold gas pressure requirements: These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 Inlet Gas Supply Pressure meters) above sea level using the standard burner...
  • Page 7: Cold Climate Insulation

    COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
  • Page 8: Vent Termination Clearances

    VENT TERMINATION CLEARANCES Vertical Vent Termination Clearances These instructions should be used as a Termination Heights For Vents guideline and do not supersede local codes Above Flat Or Sloped Roofs Ref. NFPA 54 / ANSI Z223.1 in any way. Install venting according to local codes, these instructions, the current National Roof Pitch * Feet...
  • Page 9: Appliance And Vent Clearances

    MINIMUM CLEARANCES TO COMBUSTIBLES Mantel Depth Appliance And Vent Clearances 14 (356) The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5), with the following exception: When 12 (305) inches (millimeters) the unit is installed with one side flush with a wall, the wall on the 10 (254) other side of the unit must not extend beyond the front edge of the unit (see Figure 3).
  • Page 10: Pre-Installation Steps

    PRE-INSTALLATION STEPS TYPICAL INSTALLATION SEQUENCE Step 6. (Page 16) Install and verify outside air kit operation. Front face assembly Hood The typical sequence of installation is outlined Step 7. (Page 17) Checkout appliance opera- below. However, each installation is unique tion.
  • Page 11: Step 1. Framing

    Step 1. FRAMING to fit around them. All construction above the Position the fireplace within the framing. When appliance must be self supporting, DO NOT use required, the flanges may be bent 90 degrees by Frame this appliance as illustrated in Figures 9. the appliance for structural support.
  • Page 12: Fireplace Specifications

    FIREPLACE SPECIFICATIONS Inches (millimeters) MarinST (See-Through) BRT40STTMN (See Through) 50 3/8 (1280) 48 1/4 (1200) FINISHED WALL BRACKET 48 (1219) (Front and back edge of unit top) TOP VIEW FRAMING NOTE - Unit has a factory-installed vent seal cap and vent cover plate (see Figures 22 and SPACERS 23 on page 15) in each flue outlet.
  • Page 13: Step 2. Routing Gas Line

    Step 2. ROUTING GAS LINE Step 3. INSTALL THE VENT SYSTEM Schedule 40 Black Iron Pipe Route a 1/2" (13 mm) gas line to the left side General Information Inside Diameter (Inches) of the appliance as shown in Figure 13. Gas Schedule 40 Pipe Natural Propane...
  • Page 14: Step 4. Field Wiring

    Step 4. FIELD WIRING Refer to Section A for millivolt appliances. The gas valve is set in place and pre-wired at the factory on both models. CAUTION A. Millivolt Wiring (See Figure 16) Ground supply lead must be con- nected to the wire attached to the Install Optional Control Switch (OFF/ON wall green ground screw located on the switch or remote control receiver).
  • Page 15: Step 5. Connecting Gas Line

    STEP 5. CONNECTING GAS LINE TEST ALL CONNECTIONS FOR GAS LEAKS A. Light the appliance (refer to the lighting (FACTORY AND FIELD): instructions label in the control compartment or in the Care and Operation Instructions Make gas line connections. All codes require a manual).
  • Page 16: Step 6. Outside Air Kit

    Step 6. OUTSIDE AIR KITS NOTE: Do not terminate outside air kit in attic The outside air shutter should be fully open when space under any circumstances. the fireplace is in use and completely closed when the fireplace is not being used. Closing Optional outside make-up air kits, Model CAUTION: NEVER LOCATE INLET WHERE IT it when not in use will prevent outside cold air...
  • Page 17: Step 7. Verifying Appliance Operation

    Step 7. VERIFYING APPLIANCE OPERA- MILLIVOLT Hood Igniter Rod TION Thermocouple Turn on burner and observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports.
  • Page 18 Step 8. INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: Turn off all electricity to the appliance before you install vermiculite, embers and logs. DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
  • Page 19 MARIN LOG PLACEMENT Part Number Description Number Log, Corner 55M18 Log, Rear/Left 55M19 Log, Front/Left 55M20 Log, Rear/Right 55M21 Log, Front/Center 55M22 Log, Center/Top 55M23 Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3 STEP 1 Place Bottom Hole Of Log (3) On Pin In Log (2).
  • Page 20 MARIN LOG PLACEMENT (CONTINUED) Part Number Description Number Log, Corner 55M18 Log, Rear/Left 55M19 Log, Front/Left 55M20 Log, Rear/Right 55M21 Log, Front/Center 55M22 Log, Center/Top 55M23 Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Position Small End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 21: Step 10. Burner Adjustments

    Step 9. REMOVING AND INSTALLING THE Step 10. BURNER ADJUSTMENTS Removing Glass Enclosure Panel (see Figure 29) GLASS DOOR Flame Appearance and sooting To access the glass door securing latches, first Proper flame appearance is a flame which is WARNING remove the hood by pulling firmly straight away blue at the base and becomes yellowish-orange from the unit.
  • Page 22: Step 11. Hood Installation

    Burner Adjustment Procedure WARNING • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure glass enclosure panels are in place and sealed during adjustment. CAUTION • Soot will be produced if the air shutter is closed too much.
  • Page 23: Step 12. Spillage Test/Safety Switch

    Step 12. Spillage Test and Safety Limit Manually-Reset Safety Limit Switch Switch Operation This appliance is equipped with a manually-reset blocked flue safety limit switch. Refer to Figure 33 for its location. If, during appliance operation, the flame goes out (independently of the burner Spillage Test on/off wall switch), it may be due to the operation of this safety limit switch.
  • Page 24: Step 13. Attaching Safety-In-Operation Warnings

    STEP 13. ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES It is required that the safety instruction labels fur-...
  • Page 25: Gas Conversion Kits

    GAS CONVERSION KITS Natural to Propane Gas Conversion Kit Unit Type Cat. No. WARNING Millivolt H2198 This conversion kit shall be installed by a qualified service agency in INSTALLATION INSTRUCTIONS accordance with the manufacturer’s instructions and all applicable codes Step 1. TURN OFF THE GAS SUPPLY TO THE and requirements of the authority having jurisdiction.
  • Page 26 d. Locate the latch at the top of the control Step 5. Attach manometer to the manifold compartment. To disengage the latch from side pressure test fitting and verify manifold the bottom vee-flange of the glass enclosure pressure reads 3.5" water column (0.87 kPa) panel, reach for the handle located towards for natural gas, and 10.0"...
  • Page 27: Important Safety Information

    Important Safety Information L'information de sûreté importante 1. WARNING: Do not operate appliance with the glass front 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé. removed, cracked or broken. 2.
  • Page 28 HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES It is required that the safety instruction labels fur- EN OPERACIÓN À LA SÉCURITÉ D’UTILISATION Se requiere que las etiquetas de instrucciones de nished with the fireplace be affixed to the operation Il est impératif que les étiquettes de sécurité...
  • Page 29 APPLIANCE INSTALLATION, SERVICE, APPLIANCE OPERATION NOTICES WARRANTY INFORMATION AND MAINTENANCE NOTICES Do not operate appliance with the glass Your gas appliance is covered by a limited front removed, cracked, or broken. lifetime warranty. You will find a copy of WARNING: Improper installation, the warranty accompanying this manual.
  • Page 30 These appliances comply with National Safety Deration - At higher elevations, the amount Gas Pressure - All Models Standards and are tested and listed by PFS of BTU fuel value delivered must be reduced Tables 9 and 10 show the appliances' inlet and by either using gas that has been derated by (Report No.
  • Page 31: Operation/Care Of Your Appliance

    OPERATION AND CARE OF YOUR APPLIANCE Refer to Figure 39 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 40. WARNING Millivolt Appliances - Young children should be carefully supervised when they are in the same room as the appliance.
  • Page 32: Variable Flame Adjustment

    Outside Combustion Air Controls Variable Flame Height Adjustment Inlet Pressure Port Many appliances are equipped, when installed, Manifold Pressure Port with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation.
  • Page 33 Manual-Reset Safety Limit Switch B - To access the blocked flue safety switch: WARNING This appliance is equipped with a manual-reset blocked flue safety limit switch. Refer to Figure NOTE: This procedure should only be performed Do not operate the shutoff lever 5 for its location.
  • Page 34: Maintenance

    MAINTENANCE IMPORTANT: Do not use abrasive clean- Replacing Logs ers on glass. Never clean the glass when (See Maintenance Schedule, Page 44) If the logs become damaged by accident or it is hot. improper handling and need replacement, use Refer to the maintenance schedule for maintenance only the proper replacement logs from manu- The viewing glass should be cleaned periodi- tasks, procedures, periodicity and by whom they...
  • Page 35: Front Glass Enclosure Panel, Removal And Installation

    Front Glass Enclosure Panel, Removal Locate the latch at the top of the control com- WARNING partment and disengage them from the door and Installation frame bottom vee-flange, pulling down on its Any safety screen or guard handle to open it. WARNING removed for servicing the appli- Installing Glass Enclosure Panel...
  • Page 36: Install Vermiculite, Embers And Logs

    INSTALL VERMICULITE, GLOWING EMBERS AND LOGS NOTE: Turn off all electricity to the appliance before you install vermiculite, embers and logs. DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
  • Page 37 LOG PLACEMENT Part Number Description Number Log, Corner 55M18 Log, Rear/Left 55M19 Log, Front/Left 55M20 Log, Rear/Right 55M21 Log, Front/Center 55M22 Log, Center/Top 55M23 Catalog Number for the entire log set: 55M04 Log (3) Lays Over Logs 1 And 2 STEP 3 STEP 1 Place Bottom Hole Of Log (3) On Pin In Log (2).
  • Page 38 LOG PLACEMENT (CONTINUED) Part Number Description Number Log, Corner 55M18 Log, Rear/Left 55M19 Log, Front/Left 55M20 Log, Rear/Right 55M21 Log, Front/Center 55M22 Log, Center/Top 55M23 Catalog Number for the entire log set: 55M04 Position The Round End Of Log (6) Against The Notch Of Log (4) Here.
  • Page 39: Burner Flame Adjustments

    BURNER ADJUSTMENTS Air Shutter Adjustment Guidelines The following chart is provided to aid you in achieving the correct air shutter adjustment (QUALIFIED TECHNICIANS ONLY) • If there is smoke or soot present, first check for your installation. Flame Appearance and Sooting the log set positioning to ensure that the flames are not impinging on any of the logs.
  • Page 40: Millivolt Appliance Checkout

    Burner Flame Adjustments Air Shutter MILLIVOLT Hood Igniter Rod Adjusting WARNING Thermocouple Orifice • Air shutter adjustment should only be performed by a quali- fied professional service tech- 3/8" Min nician. (9 mm) • Ensure glass enclosure panels Pilot Increase Shutter are in place and sealed during Nozzels Opening In This...
  • Page 41: Wiring Diagrams

    1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 A complete parts list is found at the end of When ordering repair parts, always give the visit us at Astria.us.com this manual. Use only parts supplied from the following information: manufacturer.
  • Page 42: Accessory Components

    ACCESSORY COMPONENTS CONTINUED ACCESSORY COMPONENTS OFF/ON Wall Switch Kit Barrier The OFF/ON wall switch kit may be used to control the Cat. No. Description Touch-Up Paint Kits operation of the fireplace burner. Install the OFF/ON wall switch in a convenient location near the fireplace. J7420 40"...
  • Page 43 ACCESSORY COMPONENTS CONTINUED Brickaded Panel Liner Kits Model Catalog Number The brickaded liner kits include ceramic panels as shown here. The panels have brick-like features in relief. Number Model Number H0779 Marin40ST EBLK-ST H0779 (Top Vent) NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 44: Maintenance Schedule

    MAINTENANCE SCHEDULE Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping and Controls for leaks. Vacuum the control compartment, fireplace logs and burner area.
  • Page 45: Lighting Instructions - Millivolt

    LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas A.
  • Page 46 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. les instructions du fournisseur.
  • Page 47: Troubleshooting Guide - Millivolt

    TROUBLESHOOTING NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM SYMPTOM POSSIBLE CAUSES...
  • Page 48: Replacement Parts List

    REPLACEMENT PARTS LIST Natural and Propane Gas Controls — SIT Millivolt Description Part No. Qty. Description Natural Propane Part No. Qty. Part No. Qty. Hood, Black - 40" J7536 Gas Valve - SIT H6209 88J53 Glass Enclosure Assembly - 40" H6365 Piezo Igniter 10K86...
  • Page 49 REPLACEMENT PARTS NOTE: See the tables on Page 48 for replacement parts applicables. Inside Location NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 50 NOTES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 51: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 52 Innovative Hearth Products Installation and Operation Instructions Astria™ Marin B-Vent Gas Fireplace 900301-01, 02/2015 Astria.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name...

Table of Contents