Gas Conversion and Specifications
Gas Specifications
- Australia:
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
Operating Pressure
Supply Pressure
Burner Aeration Gap
Gas Regulator Cap Screw
- New Zealand:
Main Burner Injector
Pilot Burner Injector
Low Fire Adjustment
Operating Pressure
Supply Pressure
Burner Aeration Gap
Gas Regulator Cap Screw
- UK Only
Category:
Flue Type:
Main Burner Injectors
Pilot Burner Injectors
Low Fire Adjustment
Operating Pressure
Supply Pressure
Burner Aeration Gap
Gas Regulator Cap Screw
NOTE:
* - Measure burner operating pressure at manifold test point with both burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart
from when carrying out Gas Conversion, if required. (Refer to 'Gas Conversion' section for details).
Natural Gas
2.10mm
0.35mm
1 turn out (c.c.w.)
1.0 kPa (*)
1.13 - 3.40 kPa
15mm (Open)
Natural Gas
2.10mm
0.35mm
1 turn out (c.c.w.)
1.0 kPa (*)
1.13 - 3.40 kPa
15mm (Open)
II
(20, 30 / 37).
2H3P
A
1.
Natural Gas (G20)
2.10mm
0.35mm
1½ turn out (c.c.w.)
10 mbar (*)
20 mbar
15mm (Open)
18
LP GAS (Propane)
1.30mm
0.23mm
½ turn out (c.c.w.)
2.5 kPa (*)
2.75 - 4.50 kPa
15mm (Open)
LP GAS
1.30mm
0.23mm
½ turn out (c.c.w.)
2.5 kPa (*)
2.75 - 4.50 kPa
15mm (Open)
Propane (G31)
1.30mm
0.23mm
½ turn out (c.c.w.)
26 mbar (*)
37 mbar
15mm (Open)