Contractor level
Contractor level
Pressing key changes the display to contractor
level.
The contractor level is segregated into display
and parameter mode.
Individual displays (e.g. A:01) and parameters
(e.g. P:01) are shown in sequence after
pressing
.
In parameter mode you can change the values
displayed above the r.h. rotary selector.
List of displays and parameters
Display list:
Index
Explanation
A 01
Set flow temperature
A 02
Actual flow temperature
A 03
Actual DHW temperature
Parameter list
Index
Explanation
P 03
Set DHW temperature
P 04
Pasteurisation
GB 01
Flow temperature hysteresis
GB 04
Upper fan speed - central heating
GB 05
Frost protection outside temperature
GB 06
Heating circuit pump mode
GB 07
Heating circuit pump run-on
GB 08
Maximum set flow temperature
GB 09
Cycle block
GB 13
Input 1
GB 14
Output 1
GB 15
DHW cylinder hysteresis
Note: Parameters GB01 to GB15 are not avaliable for all boilers; for descriptions see the
installation instructions of the relevant boiler.
Parameters GB 01 - 15 must only be modified by a heating contractor. Incorrect operation
Warning
can lead to system faults.
Parameter 5 (outside temperature frost protection) is only effective with an outside
temperature sensor.
10
Display mode
e.g. actual flow
temperature
Unit
°C
°C
°C
Setting range
15 - 65 °C for boilers type E
40 - 63 °C for boilers type K
00 - 01
1 - 20
30 - 100
-10 - 10
0 - 1
1 - 30
40 - 90
0 - 30
0 - 5
0 - 9
1 - 15
Parameter mode
e.g. gradient
Factory setting
60 °C
60 °C
0 0