[Function selection flowchart]

Setting language (English)
Item 1
Change
Language
Function
selection
Mode
selection
Display
mode setting
OCH415G
Normal display
(Display when the air conditioner is not running)
Hold down the
button and press the
Remote controller function selection mode
Item 2
English
German
Spanish
Russian
Italian
Chinese
French
Japanese
113
Hold down the
button for 2 seconds.
Dot display
Item 3
Operation lock setting is not used.
OFF
(Initial setting value)
All operation buttons except On/Off button are locked.
no1
All operation buttons are locked.
no2
The automatic mode is displayed when the operation
ON
mode is selected. (Initial setting value)
The automatic mode is not displayed when the operation mode
OFF
is selected.
The temperature range limit is not active. (Initial setting value)
OFF
The temperature range can be changed on cooling/dry mode.
The temperature range can be changed on heating mode.
The temperature range can be changed on automatic mode.
Automatic filter elevation panel up/down operation mode
Not necessary to set this mode. Refer to OPERATION MANUAL of
Optional Parts (Panel) for details on operation.
Fixed air flow direction mode
Not necessary to set this mode. Refer to OPERATION MANUAL of
indoor unit for details on operation.
The remote controller will be the main controller. (Initial setting value)
The remote controller will be the sub controller.
The clock function can be used. (Initial setting value)
ON
The clock function can not be used.
OFF
Weekly timer can be used. (Initial setting value)
Auto off timer can be used.
Simple timer can be used.
Timer mode can not be used.
The set contact numbers are not displayed in case of error.
OFF
(Initial setting value)
CALL-
The set contact numbers are displayed in case of error.
The temperature unit °C is used. (Initial setting value)
°C
°F
The temperature unit °F is used.
Room air temperature is displayed. (Initial setting value)
ON
Room air temperature is not displayed.
OFF
One of "Automatic cooling" and "Automatic heating" is displayed
ON
under the automatic mode is running. (Initial setting value)
Only "Automatic" is displayed under the automatic mode.
OFF
button and press the
button for 2 seconds.
Press the operation mode button.
Press theTIMER MENU button.
Press theTIMER ON/OFF button.
TEMP.
ON/OFF
MENU
ON/OFF
FILTER
BACK
MONITOR/SET
DAY
CHECK
TEST
OPERATION
PAR-21MAA
CLOCK
CLEAR